<?xml version="1.0" encoding="UTF-8"?><OAI-PMH xmlns="http://www.openarchives.org/OAI/2.0/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/ http://www.openarchives.org/OAI/2.0/OAI-PMH.xsd"><responseDate>2026-10-29T23:05:52Z</responseDate><request verb="GetRecord" identifier="oai:munzur-rdlopen.rawdatalibrary.net:munzur/3169" metadataPrefix="oai_dc">https://munzur-rdlopen.rawdatalibrary.net/oai/request</request><GetRecord><record><header><identifier>oai:munzur-rdlopen.rawdatalibrary.net:munzur/3169</identifier><datestamp>2026-10-28T15:39:28Z</datestamp><setSpec>openaire</setSpec><setSpec>driver</setSpec><setSpec>com_munzur_1</setSpec><setSpec>col_munzur_2</setSpec><setSpec>com_munzur_8</setSpec><setSpec>col_munzur_154</setSpec><setSpec>col_munzur_156</setSpec></header><metadata><oai_dc:dc xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd"><dc:title>Thermal Image Processing Technique for Determination of Temperature Distributions of Minced Beef Thawed by Ohmic and Conventional Methods</dc:title><dc:creator>Döner, Deniz</dc:creator><dc:creator>Çokgezme, Ömer Faruk</dc:creator><dc:creator>Çevik, Mutlu</dc:creator><dc:creator>Engin, Mustafa</dc:creator><dc:creator>İçier, Filiz</dc:creator><dc:subject>Food</dc:subject><dc:subject>Imaging</dc:subject><dc:subject>Ohmic</dc:subject><dc:subject>Temperature</dc:subject><dc:subject>Thawing</dc:subject><dc:description>In the present study, the effectiveness of ohmic thawing (OT) on temperature distribution (TD) was evaluated by using a non-destructive measurement method: thermal imaging (TI). The effects of both OT process parameters and sample properties on TD of thawed minced beef were determined. Thermal images were taken from the central cross-sectional area of a thawed sample. In the first part of the study, the effects of OT system parameters (voltage gradient; 10–13–16 V/cm and electrode type; E1:titanium foil electrode with a smooth surface, E2: needled-type titanium electrode, E3: titanium electrode with pyramid surface shaped) and sample shape (X: 13 × 4 × 3 cm3; Y: 13 × 6 × 2 cm3; Z: 13 cm height × 3.91 cm diameter) were analyzed in detail. The best thawing condition (electrode type E2 and sample shape Y) was determined by taking into account of thawing time and TD properties obtained from a developed TI processing technique. In the second part of the study, the effects of OT process on TD properties of minced beef having different fat contents (2–10–18%) were compared with those of two different conventional thawing processes (stationary cold ambient + 4 °C -RT and under cold running water + 4 °C -WT). The percentage of thawed portions in central section was above 68% for OT and varied between 12 and 54% for CT. Rectangular-shaped samples had more homogeneous temperature distributions than cylindrical samples (p &lt; 0.05). TI could be used to control the process by non-destructive monitoring of temperature during OT.</dc:description><dc:publisher>Springer</dc:publisher><dc:date>2020</dc:date><dc:type>Article</dc:type><dc:identifier>https://rdlopen.rawdatalibrary.net/r/munzur/3169</dc:identifier><dc:identifier>https://doi.org/10.1007/s11947-020-02530-w</dc:identifier><dc:identifier>1935-5130</dc:identifier><dc:language>en</dc:language><dc:relation>Food and Bioprocess Technology</dc:relation><dc:rights>info:eu-repo/semantics/openAccess</dc:rights><dc:type>info:eu-repo/semantics/article</dc:type><dc:identifier>https://munzur-rdlopen.rawdatalibrary.net/tr/items/munzur/3169</dc:identifier></oai_dc:dc></metadata></record></GetRecord></OAI-PMH>