Sürdürülebilir Kalkınma Amaçları
Bu dergideki yayınlar
3 →- MakaleYalnız künye2023Scopus SJRQ1A data-driven evaluating method on the defrosting effect of the air source heat pump system in Beijing
Guo, Yanhua; Shao, Shuangquan; Geng, Xudong; Li, Hao; Wang, Zhichao; Akkurt, Nevzat
The current demand-based defrosting initiation strategies of air source heat pumps (ASHPs) faces difficulty in achieving a balance between cost and robustness. Therefore, an efficient and innovative demand-based defrosting initiation strategy is proposed in this paper, based on the learned the degradation of heating capacity (DHC) method using data-driven model. Firstly, the DHC method is developed using the initially installed sensors without additional sensors to identify the frosty state. Subsequently, the fully connected neural network (FNN) model is established for predicting frosty state using field measured data from the ASHP system. Finally, the effectiveness of the defrosting initiation strategy is further validated through practical testing. The results demonstrate that the DHC method provides a reliable database for training the FNN model, resulting in an impressive accuracy of 91.43% for predicting the frosty state in the testing set. By adopting the innovative demand-based defrosting initiation strategies, the defrosting frequency, heating loss, and power consumption are respectively decreased by 66.3%, 2.1%, and 6.0% with the SCOP enhanced by 8.6% during a heating season. The promising results highlight that the proposed strategy effectively reduces costs while ensuring the efficiency of demand-based control.
AtıfScopus23WoS22OpenAlex27İncele
- MakaleYalnız künye2023Scopus SJRQ1Heat loss optimization and economic evaluation of a new fourth generation district heating triple pipe system
Chen, Xingli; Ren, Ling; Zheng, Qiang; Yang, Gang; Akkurt, Nevzat; Liu, Lin; Liu, Zhiwei; Qiang, Yujie; Yang, Huachao; Xu, Qian
In response to the heat loss caused by the temperature difference between the heating pipes and external environment during the pipe transportation, heat contradiction between the total heat loss of the piping system and heat transfer between tubes, as well as economic balance between the cost of heat loss and cost of material loss. Based on TOTS (Two-supply/One-return, triple pipe structure) heat loss theory of the fourth-generation district heating system, this paper optimizes structure of pipes by setting dimensionless characteristic parameters θ and β. Finally, a mathematical model is proposed to calculate economic efficiency of pipeline network by considering the cost of initial construction material loss and operation heat loss of the pipe. Results show that, from energy perspective, comprehensive heat as system energy consumption evaluation index is positively correlated with θ, decreases first and then increases as β increases. Total heat loss of system dominates comprehensive heat. Lowest comprehensive heat of system is 18.12 w/m for θ of 0.1945 and β of 0.0739. From economic perspective, total system loss cost as system economic evaluation index is positively correlated with both θ and β. Total system heat loss cost dominates total system loss cost. Lowest total system loss cost is $29.39/m for θ of 0.1945 and β of 0.0509.
AtıfScopus16OpenAlex20İncele
- MakaleYalnız künye2022Scopus SJRQ1Heat transfer performance by forced convection of microencapsulated phase change material-latent functional thermal fluid flowing in a mini-channels heat sink
Xu, Qian; Zhu, Lidong; Yan, Xinyu; Yang, Jingbin; Wang, Zhaoxiao; Liu, DingHai; Yang, Gang; Chen, Xingli; Akkurt, Nevzat; Liu, Lin
Conventional single-phase coolants have not been able to meet the high cooling requirements of electronic devices. Microencapsulated phase change material-latent functional thermal fluid (MPCM-LFTF), a solid–liquid two-phase cooling medium, has the dual advantages of active liquid cooling and passive phase change material cooling. However, it also increases the power consumption in the mini-channels, and the cooling efficiency of MPCM-LFTF in practical applications needs to be further studied. A new MPCM-LFTF was prepared by paraffin melamine resin MPCM and base fluid (absolute ethanol and deionized water) in this work. The heat transfer performance and hydrodynamic properties were investigated using the dimensionless wall temperature and friction factor, respectively. The efficiency factor was introduced to evaluate the cooling efficiency of MPCM-LFTF in mini-channels. The experimental results showed that the addition of MPCM increased the viscosity of MPCM-LFTF, which increased the friction factor. MPCM-LFTF with a mass fraction of 15 % had the best effect of temperature control and reduced the dimensionless wall temperature by 40.5 %. However, considering the characteristics of flow resistance and improved heat transfer, MPCM-LFTF with a mass fraction of 10 % had the highest cooling efficiency and the efficiency factor was 57.0 % higher than that of the base fluid.
AtıfScopus35OpenAlex36İncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| creativeworkseries.issn | 1359-4311 | |
| dc.date.accessioned | 2026-10-28T14:54:32.325355785Z | |
| dc.date.available | 2026-10-28T14:54:32.325355785Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/munzur/1747 | |
| dc.publisher | Elsevier Ltd | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | Applied Thermal Engineering |