Investigation on application of plate-tube evaporative condensating technology for data centres in the northwest of China

MakaleAçık ErişimScopus SJRQ2
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 13 · İklim Eylemi

Özet

The rapid development of data center leads to a rapid increase in energy consumption. In this paper, the plate and tube evaporative condenser is proposed for the water-cooled chiller and the data center cooling system to improve the energy efficiency in hot and dry summer and avoid icing in cold winter. The chiller can operate in the wet mode for compressor refrigeration and the dry mode for free cooling with the coefficient of performance (COP) of 5.2 in wet mode and up to 33.3 in dry mode. Furthermore, the system is applied in a data center in Ulumiqi, which is located in the dry and cold region and its ambient air temperature can vary from −32 °C to 45 °C throughout the year. The actual operation results show that the power usage effectiveness (PUE) value of the whole data centre is 1.349 in June, 1.229 in December, and 1.320 as the annual average, which is stable and efficient for five consecutive years. These results ensure the proposed system is an important technical solution for energy saving and emission reduction in data centres in cold regions.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/1834Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.egyr.2023.03.108Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
9
WoS
5
OpenAlex
8
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorWu, Xueyuan
dc.contributor.authorShao, Shuangquan
dc.contributor.authorAkkurt, Nevzat
dc.date.accessioned2026-10-28T14:54:37.829890825Z
dc.date.available2026-10-28T14:54:37.829890825Z
dc.date.issued2023
dc.description.abstractThe rapid development of data center leads to a rapid increase in energy consumption. In this paper, the plate and tube evaporative condenser is proposed for the water-cooled chiller and the data center cooling system to improve the energy efficiency in hot and dry summer and avoid icing in cold winter. The chiller can operate in the wet mode for compressor refrigeration and the dry mode for free cooling with the coefficient of performance (COP) of 5.2 in wet mode and up to 33.3 in dry mode. Furthermore, the system is applied in a data center in Ulumiqi, which is located in the dry and cold region and its ambient air temperature can vary from −32 °C to 45 °C throughout the year. The actual operation results show that the power usage effectiveness (PUE) value of the whole data centre is 1.349 in June, 1.229 in December, and 1.320 as the annual average, which is stable and efficient for five consecutive years. These results ensure the proposed system is an important technical solution for energy saving and emission reduction in data centres in cold regions.
dc.description.sponsorshipNational Natural Science Foundation of China, NSFC, (52076085)
dc.description.sponsorshipNational Natural Science Foundation of China, NSFC
dc.description.sponsorshipHuazhong University of Science and Technology, HUST, (2019QYTD10)
dc.description.sponsorshipHuazhong University of Science and Technology, HUST
dc.identifier.doi10.1016/j.egyr.2023.03.108
dc.identifier.endpage4720
dc.identifier.issn2352-4847
dc.identifier.scopus2-s2.0-85163635482
dc.identifier.startpage4713
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1834
dc.identifier.volume9
dc.identifier.wosWOS:000970855100001
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy Reports
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectData centre
dc.subjectEvaporative condenser
dc.subjectFree cooling
dc.subjectIndirect evaporation
dc.subjectPUE
dc.subject.classificationEnergy & Fuels
dc.subject.otherCooling
dc.subject.otherEmission control
dc.subject.otherEnergy efficiency
dc.subject.otherEvaporation
dc.subject.otherEvaporative cooling systems
dc.subject.other'Dry' [
dc.subject.otherCold regions
dc.subject.otherDatacenter
dc.subject.otherEnergy-consumption
dc.subject.otherEvaporative condenser
dc.subject.otherFree cooling
dc.subject.otherIndirect evaporation
dc.subject.otherPower usage
dc.subject.otherPower usage effectiveness
dc.subject.otherWater-cooled chillers
dc.subject.otherEnergy utilization
dc.titleInvestigation on application of plate-tube evaporative condensating technology for data centres in the northwest of China
dc.typeArticle
rdl.citation.openalex8
rdl.citation.scopus9
rdl.citation.wos5
rdl.oa.statusgold
rdl.oa.urlhttps://doi.org/10.1016/j.egyr.2023.03.108
rdl.scopus.quartileQ2
rdl.sdgSDG07
rdl.sdgSDG09
rdl.sdgSDG13
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)