Sürdürülebilir Kalkınma Amaçları
Yayınlar
- MakaleYalnız künye2023Scopus SJRQ1Heat loss optimization and economic evaluation of a new fourth generation district heating triple pipe system
Chen, Xingli; Ren, Ling; Zheng, Qiang; Yang, Gang; Akkurt, Nevzat; Liu, Lin; Liu, Zhiwei; Qiang, Yujie; Yang, Huachao; Xu, Qian
In response to the heat loss caused by the temperature difference between the heating pipes and external environment during the pipe transportation, heat contradiction between the total heat loss of the piping system and heat transfer between tubes, as well as economic balance between the cost of heat loss and cost of material loss. Based on TOTS (Two-supply/One-return, triple pipe structure) heat loss theory of the fourth-generation district heating system, this paper optimizes structure of pipes by setting dimensionless characteristic parameters θ and β. Finally, a mathematical model is proposed to calculate economic efficiency of pipeline network by considering the cost of initial construction material loss and operation heat loss of the pipe. Results show that, from energy perspective, comprehensive heat as system energy consumption evaluation index is positively correlated with θ, decreases first and then increases as β increases. Total heat loss of system dominates comprehensive heat. Lowest comprehensive heat of system is 18.12 w/m for θ of 0.1945 and β of 0.0739. From economic perspective, total system loss cost as system economic evaluation index is positively correlated with both θ and β. Total system heat loss cost dominates total system loss cost. Lowest total system loss cost is $29.39/m for θ of 0.1945 and β of 0.0509.
AtıfScopus16OpenAlex20İncele
- MakaleYalnız künye2022Scopus SJRQ1Heat and mass transfer mechanism and control strategy of clean low carbon combustion technology in the novel-type coke oven flue with MILD combustion
Xu, Qian; Shen, Meng; Xie, Kai; Zhang, Hui; Akkurt, Nevzat; Wang, Jiulong; Xiong, Yaxuan; Shi, Kejian; Chen, Xingli; Lv, Qian
In the field of emission reduction, considering the limitations of single clean combustion technology and joint control of carbon emission, the application of Technology of Mixed-Gas (TMG), Technology of Low-calorific Value Gas (TLVG) and Technology of Low Oxygen Combustion (TLOC) in the Novel-type Coke Oven Flue with MILD Combustion (MILD-NCOF) was realized. By adjusting the ratio of coke oven gas to blast furnace gas (α), the ratio of flue gas to gas (β) and the ratio of flue gas to air (γ), the heat and mass transfer mechanism of combustion process in MILD-NCOF was researched, the dual emission control system and the regulation strategy of pollutant and carbon emissions were established. The results showed that with the increase of α, β and γ, the fluidity of gas and the reaction rate of combustible components in the fire path were improved, the heat and mass transfer was enhanced, and the effect of dual emission reduction of pollutants and carbon emissions was improved. When the mixing ratio α was 0.6, Tave was reached at 1594.93 K. The NOx concentration at the outlet was 116.34 mg/m3, and the sum of the molar concentrations of CO and CO2 at the outlet was reduced to 1.440 × 10−1. When the mixing ratio β was 2.4, Tave was reached at 1518.73 K, the NOx concentration at the outlet was 128.42 mg/m3, and the sum of the molar concentrations of CO and CO2 at the outlet was 1.127 × 10−1. When the mixing ratio γ was 0.6, Tave was reached at 1627.28 K, the NOx concentration at the outlet was 142.73 mg/m3, and the sum of the molar concentrations of CO and CO2 was reduced to 1.128 × 10−1, which could meet the dual standards of clean production and low-carbon environmental protection of MILD-NCOF.
AtıfScopus30OpenAlex36İncele
- MakaleYalnız künye2022Scopus SJRQ1Heat transfer performance by forced convection of microencapsulated phase change material-latent functional thermal fluid flowing in a mini-channels heat sink
Xu, Qian; Zhu, Lidong; Yan, Xinyu; Yang, Jingbin; Wang, Zhaoxiao; Liu, DingHai; Yang, Gang; Chen, Xingli; Akkurt, Nevzat; Liu, Lin
Conventional single-phase coolants have not been able to meet the high cooling requirements of electronic devices. Microencapsulated phase change material-latent functional thermal fluid (MPCM-LFTF), a solid–liquid two-phase cooling medium, has the dual advantages of active liquid cooling and passive phase change material cooling. However, it also increases the power consumption in the mini-channels, and the cooling efficiency of MPCM-LFTF in practical applications needs to be further studied. A new MPCM-LFTF was prepared by paraffin melamine resin MPCM and base fluid (absolute ethanol and deionized water) in this work. The heat transfer performance and hydrodynamic properties were investigated using the dimensionless wall temperature and friction factor, respectively. The efficiency factor was introduced to evaluate the cooling efficiency of MPCM-LFTF in mini-channels. The experimental results showed that the addition of MPCM increased the viscosity of MPCM-LFTF, which increased the friction factor. MPCM-LFTF with a mass fraction of 15 % had the best effect of temperature control and reduced the dimensionless wall temperature by 40.5 %. However, considering the characteristics of flow resistance and improved heat transfer, MPCM-LFTF with a mass fraction of 10 % had the highest cooling efficiency and the efficiency factor was 57.0 % higher than that of the base fluid.
AtıfScopus35OpenAlex36İncele
- MakaleAçık Erişim2022Scopus SJRQ1Experimental study on synergistic enhancement of thermal performance of a closed two-phase thermosyphon by a TiO2nanofluid doped with Al2O3
Xu, Qian; Yang, Gang; Jia, Shuhui; Wang, Zhaoxiao; Akkurt, Nevzat; Zhang, Hui; Zhou, Qiang; Shen, Meng; Yang, Di; Zhu, Lidong
The heat transfer performance of two-phase closed thermosyphon solar collectors (TPCTs) can be improved by adding nanoparticles to the conventional working fluid, but it is necessary to ensure good rheological properties while improving the heat transfer performance. Therefore, spherical (TiO2) nanoparticles with good rheological properties and rod-shaped (Al2O3) nanoparticles with high thermal conductivity were mixed and applied to the TPCT. First, the effects of individual factors such as the concentration of nanoparticles and the operating parameters on the thermal performance of the TPCT were investigated and a regression analysis was performed. Then, the joint effect of inclination angle and filling ratio on the thermal performance of TPCT was further investigated by orthogonal experiment. The results show that doping TiO2 with Al2O3 can further improve the thermal performance of TPCT. For the volume concentration of 0.6% of nanoparticles, filling ratio of 50% and inclination angle of 80°, the best heat transfer performance of TPCT was achieved. Compared with the deionized water (DW), the thermal resistance of the single (TiO2-H2O) and hybrid (Al2O3+TiO2-H2O) nanofluid TPCT is reduced by 10.7% and 13.4%, the thermal efficiency is increased by 11.0% and 13.7%, and the equivalent heat transfer coefficient is increased by 16.2% and 18.7%, respectively.
AtıfScopus38OpenAlex41İncele
- MakaleYalnız künye2021Scopus SJRQ2Effect of the Mixing Structure Parameters of a Self-reflux Burner on Combustion Characteristics and NOx Emission
Xu, Qian; Shen, Meng; Shi, Kejian; Liu, Zhihui; Akkurt, Nevzat; Xiong, Yaxuan; Liu, Lin; Feng, Junxiao; Wang, Jiulong
To solve the problem of low efficiency of NOx emission reduction in self-reflux burners, this study is based on the concept of coordinated control of self-reflux burner structural and thermal parameters. After completing the structural design and optimization of thermal parameters, we continue to adjust the two key structural parameters: the nozzle axis distance and the length of the cylindrical section, to minimize NOx emissions. These are the two parameters that chiefly affect the mixing of flue gas and fuel gas. The results show that increasing nozzle axis distance can delay the mixing of gas and air and create a more uniform oxygen concentration field for the combustion process. The maximum combustion temperature is reduced from 1973.65 K to 1935.88 K and the volume fraction of NOx in the flue gas is reduced from 188.08×10−6 to 143.47×10−6. However, compared with the nozzle axis distance, the length of the cylindrical section of the burner has little effect on the mixing of the flow field. Under different cylindrical section lengths, the maximum combustion temperature does not change more than 3 K, and the volume fraction of NOx in the flue gas changes within 5×10−6.
AtıfScopus3OpenAlex2İncele



