- MakaleYalnız künye2023Scopus SJRQ1A data-driven evaluating method on the defrosting effect of the air source heat pump system in Beijing
Guo, Yanhua; Shao, Shuangquan; Geng, Xudong; Li, Hao; Wang, Zhichao; Akkurt, Nevzat
The current demand-based defrosting initiation strategies of air source heat pumps (ASHPs) faces difficulty in achieving a balance between cost and robustness. Therefore, an efficient and innovative demand-based defrosting initiation strategy is proposed in this paper, based on the learned the degradation of heating capacity (DHC) method using data-driven model. Firstly, the DHC method is developed using the initially installed sensors without additional sensors to identify the frosty state. Subsequently, the fully connected neural network (FNN) model is established for predicting frosty state using field measured data from the ASHP system. Finally, the effectiveness of the defrosting initiation strategy is further validated through practical testing. The results demonstrate that the DHC method provides a reliable database for training the FNN model, resulting in an impressive accuracy of 91.43% for predicting the frosty state in the testing set. By adopting the innovative demand-based defrosting initiation strategies, the defrosting frequency, heating loss, and power consumption are respectively decreased by 66.3%, 2.1%, and 6.0% with the SCOP enhanced by 8.6% during a heating season. The promising results highlight that the proposed strategy effectively reduces costs while ensuring the efficiency of demand-based control.
AtıfScopus23WoS22OpenAlex27İncele
- MakaleAçık Erişim2023Scopus SJRQ2Investigation on application of plate-tube evaporative condensating technology for data centres in the northwest of China
Wu, Xueyuan; Shao, Shuangquan; Akkurt, Nevzat
The rapid development of data center leads to a rapid increase in energy consumption. In this paper, the plate and tube evaporative condenser is proposed for the water-cooled chiller and the data center cooling system to improve the energy efficiency in hot and dry summer and avoid icing in cold winter. The chiller can operate in the wet mode for compressor refrigeration and the dry mode for free cooling with the coefficient of performance (COP) of 5.2 in wet mode and up to 33.3 in dry mode. Furthermore, the system is applied in a data center in Ulumiqi, which is located in the dry and cold region and its ambient air temperature can vary from −32 °C to 45 °C throughout the year. The actual operation results show that the power usage effectiveness (PUE) value of the whole data centre is 1.349 in June, 1.229 in December, and 1.320 as the annual average, which is stable and efficient for five consecutive years. These results ensure the proposed system is an important technical solution for energy saving and emission reduction in data centres in cold regions.
AtıfScopus9WoS5OpenAlex8İncele