Enhancing Fault Location Accuracy in Transmission Lines Using Transient Frequency Spectrum Analysis: An Investigation into Key Factors and Improvement Strategies

MakaleAçık ErişimScopus SJRQ2
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Fault location estimation in transmission lines is critical for power system reliability. Various methods have been developed for this purpose, among which transient frequency spectrum analysis (TFSA) stands out as a recent method based on travelling wave (TW) theory. TFSA determines the fault location by analyzing the frequency spectrum of transient currents and/or voltages at the instant of the fault, offering advantages such as independence from fault impedance and the ability to locate faults with one-side measurements. Despite its success in fault location, TFSA has several considerations that warrant detailed investigation. This study explores the effects of source inductance, series compensation, fault arc, and current transformer (CT) characteristics on transient frequencies. Additionally, the impact of noise on TFSA results is examined. The new proposed source inductance compensation method can reduce the error of 6.55% to 0.88%, where the same error can be reduced to 3.45% with the compensation method given in previous study. Strategies to enhance accuracy are discussed and compared to previous studies, including a proposed detection approach providing appropriate data size and precise wave propagation speed calculations. These findings contribute to a deeper understanding of TFSA’s limitations and inform practical improvements for fault location accuracy in power transmission systems.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/1647Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/electricity5040043Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
6
WoS
5
OpenAlex
3
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkdağ, Mustafa
dc.contributor.authorMamiş, Mehmet Salih
dc.contributor.authorAkmaz, Düzgün
dc.date.accessioned2026-10-28T14:54:26.449525836Z
dc.date.available2026-10-28T14:54:26.449525836Z
dc.date.issued2024
dc.description.abstractFault location estimation in transmission lines is critical for power system reliability. Various methods have been developed for this purpose, among which transient frequency spectrum analysis (TFSA) stands out as a recent method based on travelling wave (TW) theory. TFSA determines the fault location by analyzing the frequency spectrum of transient currents and/or voltages at the instant of the fault, offering advantages such as independence from fault impedance and the ability to locate faults with one-side measurements. Despite its success in fault location, TFSA has several considerations that warrant detailed investigation. This study explores the effects of source inductance, series compensation, fault arc, and current transformer (CT) characteristics on transient frequencies. Additionally, the impact of noise on TFSA results is examined. The new proposed source inductance compensation method can reduce the error of 6.55% to 0.88%, where the same error can be reduced to 3.45% with the compensation method given in previous study. Strategies to enhance accuracy are discussed and compared to previous studies, including a proposed detection approach providing appropriate data size and precise wave propagation speed calculations. These findings contribute to a deeper understanding of TFSA’s limitations and inform practical improvements for fault location accuracy in power transmission systems.
dc.identifier.doi10.3390/electricity5040043
dc.identifier.eissn2673-4826
dc.identifier.endpage876
dc.identifier.issn2673-4826
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85213440663
dc.identifier.startpage861
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1647
dc.identifier.volume5
dc.identifier.wosWOS:001386621500001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofElectricity
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectfast Fourier transform (FFT)
dc.subjectfault location
dc.subjectfrequency spectrum
dc.subjectoverhead transmission line (OTL)
dc.subjecttravelling wave (TW)
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationEngineering
dc.subject.otherCLASSIFICATION
dc.subject.otherALGORITHM
dc.subject.otherSCHEME
dc.titleEnhancing Fault Location Accuracy in Transmission Lines Using Transient Frequency Spectrum Analysis: An Investigation into Key Factors and Improvement Strategies
dc.typeArticle
rdl.citation.openalex3
rdl.citation.scopus6
rdl.citation.wos5
rdl.oa.statusgold
rdl.oa.urlhttps://www.mdpi.com/2673-4826/5/4/43/pdf?version=1730886200
rdl.scopus.quartileQ2
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)