Design of Ohmic Thawing Cell with Hydrostatic Pressure Units: Application in Minced Beef

MakaleAçık ErişimScopus SJRQ1

Özet

The thawing process is a common processing method used in the meat industry. To ensure provide food safety and protect meat quality, the thawing process should be carried out carefully. Ohmic thawing (OT) is one of the novel thawing methods. In this study, a custom-designed ohmic thawing prototype was set up and used to thaw frozen minced beef samples in different shapes (X: 13 × 4 × 3 cm3; Y: 13 × 6 × 2 cm3; Z: 13 cm height × 3.91 cm diameter) at 3 different voltage gradients (10–13-16 V/cm) by using 3 different electrode designs (E1, titanium foil; E2, needle type titanium electrode; E3, titanium embossed). The optimum OT condition resulting in a high-quality product with the highest process efficiency was determined. As an optimization procedure, a three-level general factorial design was performed. Thawing time, drip loss, thawing ratio, maximum temperature, ohmic power consumption, energy efficiency, and exergy efficiency values were used as responses. The cylindrical sample shape resulted in higher changes in quality and decreased performance of the process. The optimum ohmic thawing condition was a 16 V/cm voltage gradient for Y-shaped samples by using an E2 electrode design. The thawing time for the optimum condition was 2074s corresponding ohmic power consumption of 15.84 W. The drip loss during thawing was measured at 1.20%. The maximum temperature reached during the thawing process was recorded as 15.90 °C. Energy efficiency and exergy efficiency values were greater than 35%. Based on these results, the overall desirability of the ohmic thawing method was evaluated as 0.755. The obtained desirability value indicated the ohmic thawing method to be highly efficient and effective in achieving optimal thawing outcomes. The results of this study could give valuable information on the design of industrial-scale ohmic heating units to be used with solid foods, especially for thawing purposes.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/1867Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11947-023-03176-0Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
13
WoS
11
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDöner, Deniz
dc.contributor.authorÇokgezme, Ömer Faruk
dc.contributor.authorÇevik, Mutlu
dc.contributor.authorİçier, Filiz
dc.date.accessioned2026-10-28T14:54:40.079772288Z
dc.date.available2026-10-28T14:54:40.079772288Z
dc.date.issued2024
dc.description.abstractThe thawing process is a common processing method used in the meat industry. To ensure provide food safety and protect meat quality, the thawing process should be carried out carefully. Ohmic thawing (OT) is one of the novel thawing methods. In this study, a custom-designed ohmic thawing prototype was set up and used to thaw frozen minced beef samples in different shapes (X: 13 × 4 × 3 cm3; Y: 13 × 6 × 2 cm3; Z: 13 cm height × 3.91 cm diameter) at 3 different voltage gradients (10–13-16 V/cm) by using 3 different electrode designs (E1, titanium foil; E2, needle type titanium electrode; E3, titanium embossed). The optimum OT condition resulting in a high-quality product with the highest process efficiency was determined. As an optimization procedure, a three-level general factorial design was performed. Thawing time, drip loss, thawing ratio, maximum temperature, ohmic power consumption, energy efficiency, and exergy efficiency values were used as responses. The cylindrical sample shape resulted in higher changes in quality and decreased performance of the process. The optimum ohmic thawing condition was a 16 V/cm voltage gradient for Y-shaped samples by using an E2 electrode design. The thawing time for the optimum condition was 2074s corresponding ohmic power consumption of 15.84 W. The drip loss during thawing was measured at 1.20%. The maximum temperature reached during the thawing process was recorded as 15.90 °C. Energy efficiency and exergy efficiency values were greater than 35%. Based on these results, the overall desirability of the ohmic thawing method was evaluated as 0.755. The obtained desirability value indicated the ohmic thawing method to be highly efficient and effective in achieving optimal thawing outcomes. The results of this study could give valuable information on the design of industrial-scale ohmic heating units to be used with solid foods, especially for thawing purposes.
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK, (115O207)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştırma Kurumu, TÜBİTAK
dc.identifier.doi10.1007/s11947-023-03176-0
dc.identifier.eissn1935-5149
dc.identifier.endpage938
dc.identifier.issn1935-5130
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85165639523
dc.identifier.startpage925
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1867
dc.identifier.volume17
dc.identifier.wosWOS:001037108300001
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofFood and Bioprocess Technology
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy
dc.subjectExergy
dc.subjectOhmic
dc.subjectOptimization
dc.subjectQuality
dc.subjectThawing
dc.subject.classificationFood Science & Technology
dc.subject.otherElectric power utilization
dc.subject.otherElectrodes
dc.subject.otherEnvironmental impact
dc.subject.otherExergy
dc.subject.otherHydrostatic pressure
dc.subject.otherThawing
dc.subject.otherTitanium
dc.subject.otherCondition
dc.subject.otherElectrode design
dc.subject.otherEnergy
dc.subject.otherMinced beef
dc.subject.otherOhmic
dc.subject.otherOptimisations
dc.subject.otherQuality
dc.subject.otherThawing process
dc.subject.otherThawing time
dc.subject.otherVoltage gradient
dc.subject.otherEnergy efficiency
dc.titleDesign of Ohmic Thawing Cell with Hydrostatic Pressure Units: Application in Minced Beef
dc.typeArticle
rdl.citation.scopus13
rdl.citation.wos11
rdl.oa.statusgreen
rdl.oa.statuspreprint
rdl.oa.urlhttps://research.wur.nl/en/publications/design-of-ohmic-thawing-cell-with-hydrostatic-pressure-units-appl
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)