A new type of two-supply, one-return, triple pipe-structured heat loss model based on a low temperature district heating system

MakaleYalnız künyeScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı

Özet

Based on the design concept of a fourth-generation smart pipe network system, this paper innovatively proposes a new TOTS (Two-supply/One-return, triple pipe structure) arrangement method for district heating systems. Moreover, to accurately predict the heat loss due to the pipeline operation of the multi-pipe system, based on the multipole calculation method, a new heat loss theoretical analytical model for the TOTS was created; additionally, a corresponding three-dimensional numerical simulation model was established, which was analyzed and numerically solved. The results showed that in comparison with thermal loss data measured by Danfoss et al., the above analytical and numerical models have a high accuracy, and the deviation is within 2%. Additionally, through calculations, it was found that the distance between the heating pipes is an important factor that affects the total heat loss from the new multi-control heating system and the actual heat exchange between pipes.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2468Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
74
OpenAlex
75
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorXu, Qian
dc.contributor.authorWang, Kang
dc.contributor.authorZou, Zhenwei
dc.contributor.authorZhong, Liqiong
dc.contributor.authorAkkurt, Nevzat
dc.contributor.authorFeng, Junxiao
dc.contributor.authorXiong, Yaxuan
dc.contributor.authorHan, Jingxiao
dc.contributor.authorWang, Jiulong
dc.contributor.authorDu, Yanping
dc.date.accessioned2026-10-28T14:55:24.894652007Z
dc.date.available2026-10-28T14:55:24.894652007Z
dc.date.issued2021
dc.description.abstractBased on the design concept of a fourth-generation smart pipe network system, this paper innovatively proposes a new TOTS (Two-supply/One-return, triple pipe structure) arrangement method for district heating systems. Moreover, to accurately predict the heat loss due to the pipeline operation of the multi-pipe system, based on the multipole calculation method, a new heat loss theoretical analytical model for the TOTS was created; additionally, a corresponding three-dimensional numerical simulation model was established, which was analyzed and numerically solved. The results showed that in comparison with thermal loss data measured by Danfoss et al., the above analytical and numerical models have a high accuracy, and the deviation is within 2%. Additionally, through calculations, it was found that the distance between the heating pipes is an important factor that affects the total heat loss from the new multi-control heating system and the actual heat exchange between pipes.
dc.description.sponsorshipBasic and Applied Basic Research Fund of Guangdong, (2019A1515110743)
dc.description.sponsorshipNational Environmental and Energy Base for International Science & Technology Cooperation
dc.description.sponsorshipNational Natural Science Foundation of China, NSFC, (52006008, 62033014)
dc.description.sponsorshipNational Natural Science Foundation of China, NSFC
dc.description.sponsorshipCentral Universities in China, (FRF-BD-20-09A, FRF-TP-18-074A1)
dc.description.sponsorshipCentral Universities in China
dc.identifier.articlenumber119569
dc.identifier.doi10.1016/j.energy.2020.119569
dc.identifier.eissn1873-6785
dc.identifier.issn0360-5442
dc.identifier.scopus2-s2.0-85097784347
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2468
dc.identifier.volume218
dc.identifier.wosWOS:000611856400001
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofEnergy
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectFourth-generation district heating system
dc.subjectHeat loss model
dc.subjectMulti-pipe structure
dc.subjectMultipole method
dc.subject.other4G mobile communication systems
dc.subject.otherDistrict heating
dc.subject.otherHeat losses
dc.subject.otherHeating equipment
dc.subject.otherNumerical methods
dc.subject.otherNumerical models
dc.subject.otherTemperature
dc.subject.otherAnalytical and numerical models
dc.subject.otherDesign concept
dc.subject.otherDistrict heating system
dc.subject.otherFourth generation
dc.subject.otherHeat loss models
dc.subject.otherLow temperatures
dc.subject.otherPipeline operation
dc.subject.otherThree-dimensional numerical simulations
dc.subject.otherdesign method
dc.subject.otherheating
dc.subject.otherlow temperature
dc.subject.othernumerical model
dc.subject.otheroperations technology
dc.subject.otherpipe
dc.subject.otherpipeline
dc.subject.othertheoretical study
dc.subject.otherthree-dimensional modeling
dc.titleA new type of two-supply, one-return, triple pipe-structured heat loss model based on a low temperature district heating system
dc.typeArticle
rdl.citation.openalex75
rdl.citation.scopus74
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.sdgSDG07
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS