Theoretical Models for Tie Bar Maximum Axial Force Demand in Composite Plate Shear Walls–Concrete Filled

MakaleYalnız künyeScopus SJRQ2

Özet

This paper presents theoretical models developed for the prediction of the maximum axial force demands of tie bars of planar composite plate shear walls–concrete filled (C-PSW/CF). In the development of the theory, a previously benchmarked finite element (FE) wall model was used with some modifications. The results from the FE models were used to demonstrate the formation of the tie bar axial force demands, passive lateral confining pressure, concrete confinement, effectively confined concrete core and to develop theoretical models for the prediction of tie bar maximum force demands. The proposed method accounts for various aspects of wall geometry such as horizontal and vertical tie bar spacings, steel plate thickness, and wall thickness. The predictions of the proposed theoretical models were compared with the predictions of FE analyses by performing a parametric study involving C-PSW/CF having different tie bar spacings, plate thickness, wall thickness, and wall depths. Past experimental research available in the literature were used to evaluate the significance of the theoretical model in predicting tie bar maximum axial force demands. Tie bar axial force demand due to the confinement effect is not currently considered in the design of tie bars and there is no theoretical approach in the literature that considers the effect of confinement on the tie bar axial force demand. The theoretical models presented in this study allow the determination of the maximum axial force demands due to the confinement effect on planar C-PSW/CF tie bars without the need for complex and costly numerical analysis.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2779Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s13296-022-00625-yYayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorPolat, Erkan
dc.date.accessioned2026-10-28T14:55:47.896675144Z
dc.date.available2026-10-28T14:55:47.896675144Z
dc.date.issued2022
dc.description.abstractThis paper presents theoretical models developed for the prediction of the maximum axial force demands of tie bars of planar composite plate shear walls–concrete filled (C-PSW/CF). In the development of the theory, a previously benchmarked finite element (FE) wall model was used with some modifications. The results from the FE models were used to demonstrate the formation of the tie bar axial force demands, passive lateral confining pressure, concrete confinement, effectively confined concrete core and to develop theoretical models for the prediction of tie bar maximum force demands. The proposed method accounts for various aspects of wall geometry such as horizontal and vertical tie bar spacings, steel plate thickness, and wall thickness. The predictions of the proposed theoretical models were compared with the predictions of FE analyses by performing a parametric study involving C-PSW/CF having different tie bar spacings, plate thickness, wall thickness, and wall depths. Past experimental research available in the literature were used to evaluate the significance of the theoretical model in predicting tie bar maximum axial force demands. Tie bar axial force demand due to the confinement effect is not currently considered in the design of tie bars and there is no theoretical approach in the literature that considers the effect of confinement on the tie bar axial force demand. The theoretical models presented in this study allow the determination of the maximum axial force demands due to the confinement effect on planar C-PSW/CF tie bars without the need for complex and costly numerical analysis.
dc.identifier.doi10.1007/s13296-022-00625-y
dc.identifier.eissn2093-6311
dc.identifier.endpage1125
dc.identifier.issn1598-2351
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85132809993
dc.identifier.startpage1108
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2779
dc.identifier.volume22
dc.identifier.wosWOS:000815782100001
dc.language.isoen
dc.publisherKorean Society of Steel Construction
dc.relation.ispartofInternational Journal of Steel Structures
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectAxial force
dc.subjectComposite plate shear walls
dc.subjectConcrete-filled
dc.subjectConfinement
dc.subjectConfining pressure
dc.subjectTie bar
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherAxial flow
dc.subject.otherConcretes
dc.subject.otherForecasting
dc.subject.otherRock pressure
dc.subject.otherAxial forces
dc.subject.otherComposite plate shear wall
dc.subject.otherComposite plates
dc.subject.otherConcrete-filled
dc.subject.otherConfinement
dc.subject.otherConfining pressures
dc.subject.otherPlanar composites
dc.subject.otherPlate thickness
dc.subject.otherTheoretical modeling
dc.subject.otherTie bar
dc.subject.otherShear walls
dc.titleTheoretical Models for Tie Bar Maximum Axial Force Demand in Composite Plate Shear Walls–Concrete Filled
dc.typeArticle
rdl.citation.openalex6
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)