Compressible unsteady steam flow and heat transport analysis: a numerical investigation

MakaleYayıncıda açık erişimScopus SJRQ1

Özet

The unsteady compressible steam laminar flow associated with heat transfer in fluids in a squared cylinder is examined in this work. The current challenge was created utilizing the CFD approach. The laminar flow is chosen with a low Mach number. With the geometric wall, the flow has a no-slip condition. The pressure on the flow is kept at 0 pas, and the temperature in the flow regime is 305.13. A 0.5 m/s velocity is used to start the flow. With the use of graphics, the effects of time on velocity and pressure distributions are discussed. Different outcomes are also mentioned, such as drag coefficients, lift coefficients, and heat distributions. The velocity drops from 2.5 to 1.6 m/s at t = 7 s in the absence of anybody's force and temperature 305.13 K. Pressure increases from 0.00098 to 0.001 Pas in the flow interval of 10 s. Surface temperature increases from 360 to 375 K in time intervals of 10 s keeping pressure constant. And contour temperature increases from 371.56 to 374.2 K in time intervals of 10 s keeping the pressure constant. This information provides us with caution about the emission of steam from the chimneys of furnaces. It implies that when steam flows from a cylindrical geometry like chimneys of furnaces it heats the upper inner and outer parts which may destroy the material. So for safety, that emission should be taken for a short interval of time otherwise it will result in a havoc process. The lift coefficient remains constant and the drag coefficient increases from 0.0005 to 0.065. Under that condition, fluid has to face more resistance. To overcome that difficulty fluid should be provided with high velocity to continue it for a long time. The technique used to solve modeled problems is the Backward Difference Formula.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2824Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1038/s41598-022-23020-3Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
OpenAlex
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHussain, Azad
dc.contributor.authorArsaln, Muhammad
dc.contributor.authorRehman, Aysha
dc.contributor.authorAlharbi, Fahad M.
dc.contributor.authorAkkurt, Nevzat
dc.contributor.authorEldin, Sayed M.
dc.contributor.authorAlthobaiti, Saad
dc.date.accessioned2026-10-28T14:55:51.231170952Z
dc.date.available2026-10-28T14:55:51.231170952Z
dc.date.issued2022
dc.description.abstractThe unsteady compressible steam laminar flow associated with heat transfer in fluids in a squared cylinder is examined in this work. The current challenge was created utilizing the CFD approach. The laminar flow is chosen with a low Mach number. With the geometric wall, the flow has a no-slip condition. The pressure on the flow is kept at 0 pas, and the temperature in the flow regime is 305.13. A 0.5 m/s velocity is used to start the flow. With the use of graphics, the effects of time on velocity and pressure distributions are discussed. Different outcomes are also mentioned, such as drag coefficients, lift coefficients, and heat distributions. The velocity drops from 2.5 to 1.6 m/s at t = 7 s in the absence of anybody's force and temperature 305.13 K. Pressure increases from 0.00098 to 0.001 Pas in the flow interval of 10 s. Surface temperature increases from 360 to 375 K in time intervals of 10 s keeping pressure constant. And contour temperature increases from 371.56 to 374.2 K in time intervals of 10 s keeping the pressure constant. This information provides us with caution about the emission of steam from the chimneys of furnaces. It implies that when steam flows from a cylindrical geometry like chimneys of furnaces it heats the upper inner and outer parts which may destroy the material. So for safety, that emission should be taken for a short interval of time otherwise it will result in a havoc process. The lift coefficient remains constant and the drag coefficient increases from 0.0005 to 0.065. Under that condition, fluid has to face more resistance. To overcome that difficulty fluid should be provided with high velocity to continue it for a long time. The technique used to solve modeled problems is the Backward Difference Formula.
dc.description.sponsorshipTaif University, TU
dc.identifier.articlenumber18231
dc.identifier.doi10.1038/s41598-022-23020-3
dc.identifier.issn2045-2322
dc.identifier.issue1
dc.identifier.pmcidPMC9617894
dc.identifier.pmid36309595
dc.identifier.scopus2-s2.0-85140888372
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2824
dc.identifier.volume12
dc.identifier.wosWOS:000876608900033
dc.language.isoen
dc.publisherNature Research
dc.relation.ispartofScientific Reports
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject.otherarticle
dc.subject.otherchimney
dc.subject.otherfurnace
dc.subject.othergeometry
dc.subject.otherheat transfer
dc.subject.otherlaminar flow
dc.subject.otherMach number
dc.subject.othervelocity
dc.subject.otherwater vapor
dc.titleCompressible unsteady steam flow and heat transport analysis: a numerical investigation
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.departmentDepartment of Mathematics, University of Gujrat, Gujrat, 50700, Pakistan
rdl.departmentDepartment of Mathematics, Al-Qunfudah University College, Umm Al-Qura University, Mecca, Saudi Arabia
rdl.departmentRare Earth Elements Application and Research Center, Munzur University, 62000, Tunceli, Turkey
rdl.departmentCenter of Research, Faculty of Engineering, Future University in Egypt, New Cairo, 11835, Egypt
rdl.departmentDepartment of Sciences and Technology, Ranyah University Collage, Taif University, P.O. Box 11099, Taif, 21944, Saudi Arabia
rdl.oa.statusgold
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED