Effect of roof and ceiling configuration on energy performance of a metamaterial-based cool roof for low-rise office building in China

MakaleYalnız künyeScopus SJRQ2
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar
  • SDG 13 · İklim Eylemi

Özet

Cool roofs with higher solar reflectance and emittance can effectively reduce building energy consumption. However, it is still limited to use at night on account of the development of roof materials during the past decades. The newly proposed metamaterial-based cool roof (MCR) greatly improves the possibility of the radiative cooling in the daytime. To study the influence of MCR on the energy consumption for the office building, a small single-floor office was adopted to analyse the cooling performance of MCR by using EnergyPlus. In this study, the optimization analysis was conducted based on the proposed dimensionless thermal resistance (θRTR) and roof pitch (Δ). Then the annual electricity saving potential of the office building with MCR was evaluated in details based on the selected cities from all five climate zones in China. The results show that more annual electricity saving can be achieved under the optimized values of θR7 = 1.53 and Δ = 20°. Furthermore, more than 15.7% of annual cooling electricity saving can be achieved while the optimized θRTR and Δ are applied.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2863Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/1420326x20961556Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
13
WoS
12
OpenAlex
15
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTang, Saihong
dc.contributor.authorAkkurt, Nevzat
dc.contributor.authorZhang, Kai
dc.contributor.authorChen, Lufang
dc.contributor.authorMa, Mingquan
dc.date.accessioned2026-10-28T14:55:54.329860289Z
dc.date.available2026-10-28T14:55:54.329860289Z
dc.date.issued2021
dc.description.abstractCool roofs with higher solar reflectance and emittance can effectively reduce building energy consumption. However, it is still limited to use at night on account of the development of roof materials during the past decades. The newly proposed metamaterial-based cool roof (MCR) greatly improves the possibility of the radiative cooling in the daytime. To study the influence of MCR on the energy consumption for the office building, a small single-floor office was adopted to analyse the cooling performance of MCR by using EnergyPlus. In this study, the optimization analysis was conducted based on the proposed dimensionless thermal resistance (θRTR) and roof pitch (Δ). Then the annual electricity saving potential of the office building with MCR was evaluated in details based on the selected cities from all five climate zones in China. The results show that more annual electricity saving can be achieved under the optimized values of θR7 = 1.53 and Δ = 20°. Furthermore, more than 15.7% of annual cooling electricity saving can be achieved while the optimized θRTR and Δ are applied.
dc.description.sponsorshipJiangsu Provincial Department of Housing and Urban Rural Construction, (2018ZD067)
dc.description.sponsorshipPostgraduate Research & Practice Innovation Program of Jiangsu Province, (SJCX20_0329)
dc.description.sponsorshipNational Natural Science Foundation of China, NSFC, (51878342)
dc.description.sponsorshipNational Natural Science Foundation of China, NSFC
dc.identifier.articlenumber1420326X20961556
dc.identifier.doi10.1177/1420326x20961556
dc.identifier.eissn1423-0070
dc.identifier.endpage1750
dc.identifier.issn1420-326X
dc.identifier.issue10
dc.identifier.scopus2-s2.0-85093961256
dc.identifier.startpage1739
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2863
dc.identifier.volume30
dc.identifier.wosWOS:000637137800001
dc.language.isoen
dc.publisherSAGE Publications Ltd
dc.relation.ispartofIndoor and Built Environment
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCool roof
dc.subjectEnergy consumption
dc.subjectOffice building
dc.subjectRoof pitch
dc.subjectThermal resistance of roof and ceiling
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEngineering, Environmental
dc.subject.classificationPublic, Environmental & Occupational Health
dc.subject.classificationEngineering
dc.subject.otherarticle
dc.subject.otherChina
dc.subject.othercity
dc.subject.otherclimate
dc.subject.othercooling
dc.subject.otherelectricity
dc.subject.otherenergy consumption
dc.subject.otherheat tolerance
dc.subject.otherpitch
dc.titleEffect of roof and ceiling configuration on energy performance of a metamaterial-based cool roof for low-rise office building in China
dc.typeArticle
rdl.citation.openalex15
rdl.citation.scopus13
rdl.citation.wos12
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.sdgSDG07
rdl.sdgSDG13
rdl.sdgSDG11
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)