Investigation of Tie Bars Axial Force Demands in Composite Plate Shear Walls—Concrete Filled

MakaleYalnız künyeScopus SJRQ2

Özet

Tie bars axial force demands due to concrete dilation and prying action were investigated through numerical studies. In the first part of this study, the Karagozian and Case Concrete model, which proved to provide reasonable in-plane flexural cyclic inelastic wall response while accounting for concrete dilation effect, was used to investigate the variation of confinement inside the infill concrete, the distribution of passive confining pressures at the steel–concrete interface, and the resulting tie bar axial force demands. Finite element analyses involving C-PSW/CF having different tie spacings, wall depths, and wall thicknesses were performed. In the second part of this study, the influence of plate local buckling on tie bar axial force demand was investigated and explained by prying action. A separate finite element study was performed to investigate the significance of prying action and equations were developed from free-body diagrams. The results showed the significance of the passive confining pressures due to concrete dilation, and prying action due to local plate buckling, on imparting axial forces in tie bars. Neither of these behavior are currently considered as design parameters for tie bars. The numerical analyses and results presented here are intended to provide useful insights and direction for the design and instrumentation of future C-PSW/CF experiments by the broader research community.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2959Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s13296-021-00480-3Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
9
WoS
8
OpenAlex
8
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorPolat, Erkan
dc.contributor.authorKenarangi, Hadi
dc.contributor.authorBruneau, Michel
dc.date.accessioned2026-10-28T14:56:02.231363248Z
dc.date.available2026-10-28T14:56:02.231363248Z
dc.date.issued2021
dc.description.abstractTie bars axial force demands due to concrete dilation and prying action were investigated through numerical studies. In the first part of this study, the Karagozian and Case Concrete model, which proved to provide reasonable in-plane flexural cyclic inelastic wall response while accounting for concrete dilation effect, was used to investigate the variation of confinement inside the infill concrete, the distribution of passive confining pressures at the steel–concrete interface, and the resulting tie bar axial force demands. Finite element analyses involving C-PSW/CF having different tie spacings, wall depths, and wall thicknesses were performed. In the second part of this study, the influence of plate local buckling on tie bar axial force demand was investigated and explained by prying action. A separate finite element study was performed to investigate the significance of prying action and equations were developed from free-body diagrams. The results showed the significance of the passive confining pressures due to concrete dilation, and prying action due to local plate buckling, on imparting axial forces in tie bars. Neither of these behavior are currently considered as design parameters for tie bars. The numerical analyses and results presented here are intended to provide useful insights and direction for the design and instrumentation of future C-PSW/CF experiments by the broader research community.
dc.description.sponsorshipState University of New York, SUNY
dc.identifier.doi10.1007/s13296-021-00480-3
dc.identifier.eissn2093-6311
dc.identifier.endpage921
dc.identifier.issn1598-2351
dc.identifier.issue3
dc.identifier.scopus2-s2.0-85103415925
dc.identifier.startpage901
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2959
dc.identifier.volume21
dc.identifier.wosWOS:000635875000001
dc.language.isoen
dc.publisherKorean Society of Steel Construction
dc.relation.ispartofInternational Journal of Steel Structures
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectComposite plate shear walls
dc.subjectConcrete-filled
dc.subjectConfinement
dc.subjectConfining pressure
dc.subjectPrying action
dc.subjectTie bar
dc.subject.classificationConstruction & Building Technology
dc.subject.classificationEngineering, Civil
dc.subject.classificationEngineering
dc.subject.otherAxial flow
dc.subject.otherBuckling
dc.subject.otherPlates (structural components)
dc.subject.otherRock pressure
dc.subject.otherThermoelectricity
dc.subject.otherComposite plates
dc.subject.otherConcrete interface
dc.subject.otherConcrete-filled
dc.subject.otherConfining pressures
dc.subject.otherDesign parameters
dc.subject.otherFinite-element study
dc.subject.otherFree body diagrams
dc.subject.otherResearch communities
dc.subject.otherConcretes
dc.titleInvestigation of Tie Bars Axial Force Demands in Composite Plate Shear Walls—Concrete Filled
dc.typeArticle
rdl.citation.openalex8
rdl.citation.scopus9
rdl.citation.wos8
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)