Influence of cross-section geometry on air demand ratio in high-head conduits with a radial gate

MakaleAçık ErişimScopus SJRQ3

Özet

When the gate of a high-head conduit is partly opened, negative pressure draws the air in through the air vent. Air that is entrained into the water is instantly forced downstream in the form of air bubbles. When studies on high-head gated conduits were examined, it was determined that the air demand ratio varied depending on many hydraulic and geometric parameters. This work has focused on determining the effect of conduit cross-section geometry on the air-demand ratio. A series of experiments were carried out on high-head radial gated conduits having different cross-section geometries. Experimental results showed that conduit cross-section geometry had an important effect on the air demand ratio especially in small gate opening rates. Further, design equations for the air demand ratio are presented relating the air demand ratio to Froude number, gate opening rate, and the ratio of gate opening to conduit length.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3035Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.2166/ws.2021.162Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
8
OpenAlex
10
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAydin, Alp Bugra
dc.contributor.authorBaylar, Ahmet
dc.contributor.authorOzkan, Fahri
dc.contributor.authorTuna, Muhammed Cihat
dc.contributor.authorOzturk, Mualla
dc.date.accessioned2026-10-28T14:56:08.025938874Z
dc.date.available2026-10-28T14:56:08.025938874Z
dc.date.issued2021
dc.description.abstractWhen the gate of a high-head conduit is partly opened, negative pressure draws the air in through the air vent. Air that is entrained into the water is instantly forced downstream in the form of air bubbles. When studies on high-head gated conduits were examined, it was determined that the air demand ratio varied depending on many hydraulic and geometric parameters. This work has focused on determining the effect of conduit cross-section geometry on the air-demand ratio. A series of experiments were carried out on high-head radial gated conduits having different cross-section geometries. Experimental results showed that conduit cross-section geometry had an important effect on the air demand ratio especially in small gate opening rates. Further, design equations for the air demand ratio are presented relating the air demand ratio to Froude number, gate opening rate, and the ratio of gate opening to conduit length.
dc.description.sponsorshipTÜBİTAK, (215M046)
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK
dc.identifier.doi10.2166/ws.2021.162
dc.identifier.eissn1607-0798
dc.identifier.endpage4097
dc.identifier.issn1606-9749
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85121789275
dc.identifier.startpage4086
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3035
dc.identifier.volume21
dc.identifier.wosWOS:000658307200001
dc.language.isoen
dc.publisherIWA Publishing
dc.relation.ispartofWater Supply
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAir demand
dc.subjectConduit
dc.subjectCross-section geometry
dc.subjectHigh-head flow
dc.subjectRadial gate
dc.subject.classificationEngineering, Environmental
dc.subject.classificationEnvironmental Sciences
dc.subject.classificationWater Resources
dc.subject.classificationEngineering
dc.subject.classificationEnvironmental Sciences & Ecology
dc.subject.otherGeometry
dc.subject.otherAir bubbles
dc.subject.otherAir demand
dc.subject.otherAir vents
dc.subject.otherConduit
dc.subject.otherCross-section geometry
dc.subject.otherDown-stream
dc.subject.otherGate openings
dc.subject.otherHigh-head flow
dc.subject.otherNegative pressures
dc.subject.otherRadial gates
dc.subject.othercross section
dc.subject.otherdesign method
dc.subject.otherparameter estimation
dc.subject.otherarticle
dc.subject.otherhuman
dc.subject.otherCanal gates
dc.titleInfluence of cross-section geometry on air demand ratio in high-head conduits with a radial gate
dc.typeArticle
rdl.citation.openalex10
rdl.citation.scopus7
rdl.citation.wos8
rdl.oa.statushybrid
rdl.oa.urlhttps://doi.org/10.2166/ws.2021.162
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)