Investigation of issues affecting thermal comfort in water system underfloor heating applications of buildings with Bayesian networks

MakaleAçık ErişimScopus SJRQ3

Özet

Thermal comfort is related to the stability of the ambient temperature. Constant changes in ambient temperature appear as a situation that negatively affects comfort. The selected building systems must be arranged to maintain this stability for the continuity of thermal comfort. In this study, issues affecting thermal comfort in water system underfloor heating applications of buildings are handled and analyzed using the Bayesian Network modeling methodology. Visual examples of the problems encountered in field applications are also given. Three different scenarios are tested with the constructed Bayesian Network model. In the first scenario, assumed that mechanical project failures were prevented. In this case, it was observed that the failure rate decreased by about 5%. In the second scenario, assumed that mechanical application failures are prevented along with mechanical project failures. The failure rate decreased by 11% compared to the first situation. The third scenario assumed that the mechanical project preparation phase was concluded without any problems, the mechanical project was implemented without any failures, and the mechanical system was commissioned without any problems. In the last scenario, the failure rate decreased by 14% compared to the first case, and the probability of not providing thermal comfort remained at 2%. As a result of these three scenarios, the possibility of not providing thermal comfort in the underfloor heating system is detailed and interpreted.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3066Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.18186/thermal.1332410Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
OpenAlex
0
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorErkol, Samet
dc.contributor.authorYücesan, Melih
dc.contributor.authorGül, Muhammet
dc.contributor.authorGüneri, Ali Fuat
dc.date.accessioned2026-10-28T14:56:10.683897892Z
dc.date.available2026-10-28T14:56:10.683897892Z
dc.date.issued2023
dc.description.abstractThermal comfort is related to the stability of the ambient temperature. Constant changes in ambient temperature appear as a situation that negatively affects comfort. The selected building systems must be arranged to maintain this stability for the continuity of thermal comfort. In this study, issues affecting thermal comfort in water system underfloor heating applications of buildings are handled and analyzed using the Bayesian Network modeling methodology. Visual examples of the problems encountered in field applications are also given. Three different scenarios are tested with the constructed Bayesian Network model. In the first scenario, assumed that mechanical project failures were prevented. In this case, it was observed that the failure rate decreased by about 5%. In the second scenario, assumed that mechanical application failures are prevented along with mechanical project failures. The failure rate decreased by 11% compared to the first situation. The third scenario assumed that the mechanical project preparation phase was concluded without any problems, the mechanical project was implemented without any failures, and the mechanical system was commissioned without any problems. In the last scenario, the failure rate decreased by 14% compared to the first case, and the probability of not providing thermal comfort remained at 2%. As a result of these three scenarios, the possibility of not providing thermal comfort in the underfloor heating system is detailed and interpreted.
dc.identifier.doi10.18186/thermal.1332410
dc.identifier.eissn2148-7847
dc.identifier.endpage978
dc.identifier.issn2148-7847
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85168826267
dc.identifier.startpage968
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3066
dc.identifier.volume9
dc.identifier.wosWOS:001048847800010
dc.language.isoen
dc.publisherYildiz Technical University
dc.relation.ispartofJournal of Thermal Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBayesian Network
dc.subjectThermal Comfort
dc.subjectWater System Underfloor Heating
dc.subject.classificationThermodynamics
dc.titleInvestigation of issues affecting thermal comfort in water system underfloor heating applications of buildings with Bayesian networks
dc.typeArticle
rdl.citation.openalex0
rdl.citation.scopus0
rdl.citation.trdizin0
rdl.citation.wos0
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/3285539
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexTRDIZIN
rdl.wos.indexEmerging Sources Citation Index (ESCI)