Evaluation of the gamma and neutron shielding properties of 64 TeO 2+ 15 ZnO + (20 - x) CdO + xBaO + 1 V 2O 5 glass system using Geant4 simulation and Phy-X database software

MakaleYalnız künyeScopus SJRQ2

Özet

In this study, fast neutron removal cross-section and γ-ray shielding capabilities in terms of mass attenuation coefficient (μm), transmission fractions (T), effective atomic numbers (Zeff), half-value layer (HVL) and exposure build-up factors (EBF) of the 64 TeO 2+ 15 ZnO + (20 - x) CdO + xBaO + 1 V 2O 5 (x= 0 , 5 , 10 , 15 , 20 mol%) glass system have been evaluated using Monte Carlo simulations carried out with Geant4 model of the high-purity germanium (HPGe) detector and Phy-X database software. The results of this study revealed that γ-ray shielding capability of the studied glass system increases with the increase of BaO content and decrease of CdO content in the chemical structure due to the high atomic number (Z) of Ba compared to Cd. The results also showed that increase of BaO fraction in the glass structure weakens the neutron shielding ability and by the use of low Z elements in the composites better shielding performance against neutrons can be obtained.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3265Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s12043-020-01972-3Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAşkin, A.
dc.date.accessioned2026-10-28T14:56:24.710000635Z
dc.date.available2026-10-28T14:56:24.710000635Z
dc.date.issued2020
dc.description.abstractIn this study, fast neutron removal cross-section and γ-ray shielding capabilities in terms of mass attenuation coefficient (μm), transmission fractions (T), effective atomic numbers (Zeff), half-value layer (HVL) and exposure build-up factors (EBF) of the 64 TeO 2+ 15 ZnO + (20 - x) CdO + xBaO + 1 V 2O 5 (x= 0 , 5 , 10 , 15 , 20 mol%) glass system have been evaluated using Monte Carlo simulations carried out with Geant4 model of the high-purity germanium (HPGe) detector and Phy-X database software. The results of this study revealed that γ-ray shielding capability of the studied glass system increases with the increase of BaO content and decrease of CdO content in the chemical structure due to the high atomic number (Z) of Ba compared to Cd. The results also showed that increase of BaO fraction in the glass structure weakens the neutron shielding ability and by the use of low Z elements in the composites better shielding performance against neutrons can be obtained.
dc.identifier.articlenumber97
dc.identifier.doi10.1007/s12043-020-01972-3
dc.identifier.eissn0973-7111
dc.identifier.issn0304-4289
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85087283639
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3265
dc.identifier.volume94
dc.identifier.wosWOS:000763401100004
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofPramana - Journal of Physics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject07.05.Tp
dc.subject29.30.Kv
dc.subject29.40.Wk
dc.subjectfast neutron removal
dc.subjectGeant4
dc.subjectglasses
dc.subjectPhoton attenuation
dc.subjectPhy-X
dc.subject.classificationPhysics, Multidisciplinary
dc.subject.classificationPhysics
dc.subject.otherAtoms
dc.subject.otherBarium compounds
dc.subject.otherCadmium compounds
dc.subject.otherComputer software
dc.subject.otherGamma rays
dc.subject.otherGermanium compounds
dc.subject.otherGlass
dc.subject.otherII-VI semiconductors
dc.subject.otherIntelligent systems
dc.subject.otherMonte Carlo methods
dc.subject.otherNeutrons
dc.subject.otherOxide minerals
dc.subject.otherRadiation shielding
dc.subject.otherVanadium pentoxide
dc.subject.otherX ray detectors
dc.subject.otherZinc oxide
dc.subject.otherDatabase software
dc.subject.otherEffective atomic number
dc.subject.otherGamma-ray shielding
dc.subject.otherGEANT4 simulation
dc.subject.otherHigh purity germanium detectors
dc.subject.otherMass attenuation coefficients
dc.subject.otherNeutron shielding
dc.subject.otherShielding performance
dc.subject.otherPhosphorus compounds
dc.titleEvaluation of the gamma and neutron shielding properties of 64 TeO 2+ 15 ZnO + (20 - x) CdO + xBaO + 1 V 2O 5 glass system using Geant4 simulation and Phy-X database software
dc.typeArticle
rdl.citation.openalex6
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)