Calibration-free extraction of constitutive parameters of magnetically coupled anisotropic metamaterials using waveguide measurements

MakaleAçık ErişimScopus SJRQ2

Özet

A calibration-free method for extraction of electromagnetic properties of magnetically coupled anisotropic biaxial metamaterial (MM) slabs from waveguide measurements is proposed. It relies on three measurement steps (thru, empty line, and the same line arbitrarily loaded by the MM slab) to extract electromagnetic properties. It is evaluated against another calibration-dependent method for retrieval of electromagnetic properties of a MM slab constructed by C-shaped resonators. From evaluation analysis, we note that our method, as compared to the calibration-dependent method, not only accurately extracts electromagnetic properties without requiring the use of expensive calibration standards but also is reference-invariant.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3298Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1063/1.4997096Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
10
OpenAlex
11
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHasar, U.C.
dc.contributor.authorBuldu, G.
dc.contributor.authorBute, M.
dc.contributor.authorMuratoglu, A.
dc.date.accessioned2026-10-28T14:56:27.260121609Z
dc.date.available2026-10-28T14:56:27.260121609Z
dc.date.issued2017
dc.description.abstractA calibration-free method for extraction of electromagnetic properties of magnetically coupled anisotropic biaxial metamaterial (MM) slabs from waveguide measurements is proposed. It relies on three measurement steps (thru, empty line, and the same line arbitrarily loaded by the MM slab) to extract electromagnetic properties. It is evaluated against another calibration-dependent method for retrieval of electromagnetic properties of a MM slab constructed by C-shaped resonators. From evaluation analysis, we note that our method, as compared to the calibration-dependent method, not only accurately extracts electromagnetic properties without requiring the use of expensive calibration standards but also is reference-invariant.
dc.identifier.articlenumber104702
dc.identifier.doi10.1063/1.4997096
dc.identifier.eissn1089-7623
dc.identifier.issn0034-6748
dc.identifier.issue10
dc.identifier.pmid29092501
dc.identifier.scopus2-s2.0-85031668402
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3298
dc.identifier.volume88
dc.identifier.wosWOS:000414174000036
dc.language.isoen
dc.publisherAmerican Institute of Physics Inc.
dc.relation.ispartofReview of Scientific Instruments
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.otherAnisotropy
dc.subject.otherExtraction
dc.subject.otherMetamaterials
dc.subject.otherWaveguides
dc.subject.otherAnisotropic metamaterials
dc.subject.otherC-shaped
dc.subject.otherCalibration free
dc.subject.otherCalibration standard
dc.subject.otherCalibration-free methods
dc.subject.otherConstitutive parameters
dc.subject.otherElectromagnetic properties
dc.subject.otherWaveguide measurements
dc.subject.othercalibration
dc.subject.otherinformation retrieval
dc.subject.otherarticle
dc.titleCalibration-free extraction of constitutive parameters of magnetically coupled anisotropic metamaterials using waveguide measurements
dc.typeArticle
rdl.citation.openalex11
rdl.citation.scopus10
rdl.departmentDepartment of Electrical and Electronics Engineering, University of Gaziantep, 27310 Gaziantep, Turkey
rdl.departmentDepartment of Electrical and Electronics Engineering, Munzur University, Tunceli 62000, Turkey
rdl.departmentDepartment of Mechanical Engineering, Turkisch-Deutsche Universitat, 34820 Istanbul, Turkey
rdl.oa.statusgreen
rdl.oa.statusclosed
rdl.oa.urlhttps://hdl.handle.net/11511/63307
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED