Assessment of the mass attenuation coefficients of granite, basalt, andesite and tuff stones with the Geant4 model of a high-purity germanium detector

MakaleYalnız künyeScopus SJRQ3

Özet

In this work, the radiation shielding properties of various natural stones, such as granite, basalt, andesite and tuff, were determined by using Monte-Carlo simulations performed with the Geant4 model of a high-purity germanium (HPGe) detector. Mass attenuation coefficients were calculated for γ-ray energies of 80.9, 140.5, 356.5, 661.6, 1173.2 and 1332.5 keV and for the sample thicknesses between 1 and 7 cm. The results of this study indicate that the stone samples have lower mass attenuation values varying in the range from - 28.8 % to - 3.7 % compared to lead. Among the measured stone samples, the mass attenuation values of tuff stone are closest to lead (above 661.6 keV).

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3411Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s12043-019-1780-9Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
8
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAşkin, A.
dc.contributor.authorDal, M.
dc.date.accessioned2026-10-28T14:56:36.277329828Z
dc.date.available2026-10-28T14:56:36.277329828Z
dc.date.issued2019
dc.description.abstractIn this work, the radiation shielding properties of various natural stones, such as granite, basalt, andesite and tuff, were determined by using Monte-Carlo simulations performed with the Geant4 model of a high-purity germanium (HPGe) detector. Mass attenuation coefficients were calculated for γ-ray energies of 80.9, 140.5, 356.5, 661.6, 1173.2 and 1332.5 keV and for the sample thicknesses between 1 and 7 cm. The results of this study indicate that the stone samples have lower mass attenuation values varying in the range from - 28.8 % to - 3.7 % compared to lead. Among the measured stone samples, the mass attenuation values of tuff stone are closest to lead (above 661.6 keV).
dc.identifier.articlenumber14
dc.identifier.doi10.1007/s12043-019-1780-9
dc.identifier.eissn0973-7111
dc.identifier.issn0304-4289
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85065780076
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3411
dc.identifier.volume93
dc.identifier.wosWOS:000468654400002
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofPramana - Journal of Physics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectGeant4
dc.subjecthigh-purity germanium
dc.subjectMass attenuation coefficient
dc.subjectMonte-Carlo simulation
dc.subjectnatural stone
dc.subject.classificationPhysics, Multidisciplinary
dc.subject.classificationPhysics
dc.subject.otherBasalt
dc.subject.otherGamma rays
dc.subject.otherGermanium
dc.subject.otherGermanium compounds
dc.subject.otherGranite
dc.subject.otherIntelligent systems
dc.subject.otherPhosphorus compounds
dc.subject.otherRadiation shielding
dc.subject.otherGamma-ray energy
dc.subject.otherGeant4
dc.subject.otherHigh purity germanium detectors
dc.subject.otherHigh purity germaniums
dc.subject.otherMass attenuation
dc.subject.otherMass attenuation coefficients
dc.subject.otherNatural stones
dc.subject.otherShielding properties
dc.subject.otherMonte Carlo methods
dc.titleAssessment of the mass attenuation coefficients of granite, basalt, andesite and tuff stones with the Geant4 model of a high-purity germanium detector
dc.typeArticle
rdl.citation.openalex8
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)