Assessment and ICP-MS determination of toxic metal content (Cd, Cr, Ni, and Pb) in Ibrkish chicken meat for use as bioindicator for human health

MakaleYalnız künyeScopus SJRQ3

Özet

The aim of this study was to determine the toxic metal concentrations in chicken meat consumed by the Turkish population and to establish health risk assessment. The concentrations of cadmium (Cd), chromium (Cr), nickel (Ni), and lead (Pb) in chicken meat produced by seven different suppliers were determined using inductively coupled plasma mass spectrometry (ICP- MS). The Cd concentrations in all samples were found to be lower than the maximum allowable concentration (MAC) of 50 Hg kg-1. The Cr and Ni concentrations in all samples were lower than 700 and 450 μg kg-1, respectively, with the exception of Cr in the samples from one producer and of Ni from two other producers. The Pb concentrations (max. 413 μg kg-1) in the samples from three producers were found to be higher than the MAC of 100 μg kg-1. Although the concentrations of lead in some samples exceed the limits set by the authorities, risk of developing cancer over a human lifetime was found to be not significant (between 3 to 16 per 1,000,000 persons).

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3598Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
8
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaraaslan, Nagihan M.
dc.contributor.authorYaman, Mehmet
dc.date.accessioned2026-10-28T14:56:50.560664654Z
dc.date.available2026-10-28T14:56:50.560664654Z
dc.date.issued2018
dc.description.abstractThe aim of this study was to determine the toxic metal concentrations in chicken meat consumed by the Turkish population and to establish health risk assessment. The concentrations of cadmium (Cd), chromium (Cr), nickel (Ni), and lead (Pb) in chicken meat produced by seven different suppliers were determined using inductively coupled plasma mass spectrometry (ICP- MS). The Cd concentrations in all samples were found to be lower than the maximum allowable concentration (MAC) of 50 Hg kg-1. The Cr and Ni concentrations in all samples were lower than 700 and 450 μg kg-1, respectively, with the exception of Cr in the samples from one producer and of Ni from two other producers. The Pb concentrations (max. 413 μg kg-1) in the samples from three producers were found to be higher than the MAC of 100 μg kg-1. Although the concentrations of lead in some samples exceed the limits set by the authorities, risk of developing cancer over a human lifetime was found to be not significant (between 3 to 16 per 1,000,000 persons).
dc.identifier.endpage21
dc.identifier.issn0195-5373
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85045311425
dc.identifier.startpage16
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3598
dc.identifier.volume39
dc.language.isoen
dc.publisherPerkin - Elmer Corp.
dc.relation.ispartofAtomic Spectroscopy
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.titleAssessment and ICP-MS determination of toxic metal content (Cd, Cr, Ni, and Pb) in Ibrkish chicken meat for use as bioindicator for human health
dc.typeArticle
rdl.citation.scopus8
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS