Investigation of the radiation shielding capability of xPbO – (50 - x) BaO – 50 B 2O 3 glass system using Geant4, Fluka, WinXCOM and comparison of data with the experimental data

MakaleYalnız künyeScopus SJRQ2

Özet

In this study, mass attenuation coefficient (μm), transmission fractions (T), effective atomic numbers (Z eff) and half-value layer (HVL) of the xPbO –(50 - x) BaO –50 B 2O 3 (where x=10,20,30,40mol%) glass system have been determined from the Monte Carlo simulations carried out with Geant4 and Fluka simulation toolkits and WinXCOM database software. The calculated results were compared with the experimentally obtained μm values of the selected glass in order to validate the Geant4 model of HPGe detector and Fluka model of NaI(Tl) detectors. T, Z eff and HVL shielding parameters of the studied glass system indicate that increase of PbO content from 10 to 40% results in a better shielding behaviour thanks to the high atomic number of lead.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3721Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s12043-019-1890-4Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
12
WoS
8
OpenAlex
12
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAşkin, A.
dc.contributor.authorMutuwong, C.
dc.contributor.authorNutaro, T.
dc.contributor.authorDal, M.
dc.date.accessioned2026-10-28T14:57:01.384432219Z
dc.date.available2026-10-28T14:57:01.384432219Z
dc.date.issued2020
dc.description.abstractIn this study, mass attenuation coefficient (μm), transmission fractions (T), effective atomic numbers (Z eff) and half-value layer (HVL) of the xPbO –(50 - x) BaO –50 B 2O 3 (where x=10,20,30,40mol%) glass system have been determined from the Monte Carlo simulations carried out with Geant4 and Fluka simulation toolkits and WinXCOM database software. The calculated results were compared with the experimentally obtained μm values of the selected glass in order to validate the Geant4 model of HPGe detector and Fluka model of NaI(Tl) detectors. T, Z eff and HVL shielding parameters of the studied glass system indicate that increase of PbO content from 10 to 40% results in a better shielding behaviour thanks to the high atomic number of lead.
dc.identifier.articlenumber11
dc.identifier.doi10.1007/s12043-019-1890-4
dc.identifier.eissn0973-7111
dc.identifier.issn0304-4289
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85076459226
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3721
dc.identifier.volume94
dc.identifier.wosWOS:000540714900011
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofPramana - Journal of Physics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subject07.05.Tp
dc.subject29.30.Kv
dc.subject29.40.Wk
dc.subjectFluka
dc.subjectGeant4
dc.subjectglasses
dc.subjectPhoton attenuation
dc.subjectWinXCOM
dc.subject.classificationPhysics, Multidisciplinary
dc.subject.classificationPhysics
dc.subject.otherAtoms
dc.subject.otherBarium compounds
dc.subject.otherComputer software
dc.subject.otherGermanium compounds
dc.subject.otherGlass
dc.subject.otherIntelligent systems
dc.subject.otherIodine compounds
dc.subject.otherLead oxide
dc.subject.otherMonte Carlo methods
dc.subject.otherRadiation shielding
dc.subject.otherSodium Iodide
dc.subject.other07.05.Tp
dc.subject.other29.30.Kv
dc.subject.other29.40.Wk
dc.subject.otherFluka
dc.subject.otherGeant4
dc.subject.otherPhoton attenuation
dc.subject.otherWinXCOM
dc.subject.otherPhosphorus compounds
dc.titleInvestigation of the radiation shielding capability of xPbO – (50 - x) BaO – 50 B 2O 3 glass system using Geant4, Fluka, WinXCOM and comparison of data with the experimental data
dc.typeArticle
rdl.citation.openalex12
rdl.citation.scopus12
rdl.citation.wos8
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)