Sürdürülebilir Kalkınma Amaçları

Yayınları

4 →
  • MakaleAçık Erişim2015Scopus SJRQ2
    Investigation of flexural strength and cytotoxicity of acrylic resin copolymers by using different polymerization methods

    Sahin, Onur; Ozdemir, Ali Kemal; Turgut, Mehmet; Boztug, Ali; Sumer, Zeynep

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfOpenAlex28
    Web of Scienceİncele
  • MakaleYalnız künye2013Scopus SJRQ2
    Amine-modified maleic anhydride containing terpolymers for the adsorption of uranyl ion in aqueous solutions

    Simsek, Selcuk; Yilmaz, Ersen; Boztug, Ali

    Maleic anhydride-styrene-methyl methacrylate (MA-S-MM) terpolymer was prepared. It was modified by ethylenediamine (EDA) and diethylenetriamine (DETA) in order to get cross-linked polymers bearing carboxyl and amine groups. Modified polymers used as an adsorbent for the removal of UO2 (2+) from water. The characterizations of structures of all the polymers were performed by Fourier transform infrared. The adsorptive features of adsorbents were then investigated for UO2 (2+) in view of dependency on ion concentration, pH, temperature and kinetics. Experimentally obtained isotherms were evaluated with reference to Langmuir, Freundlich and Dubinin-Radushkevich models. The maximum monolayer adsorption capacity for UO2 (2+) was found to be 1.59 and 2.43 mol kg(-1) for EDA-MA-S-MM and DETA-MA-S-MM, respectively. It can be said that the new modified polymers prepared in our laboratory have been suggested as new adsorbents for uranyl ions.

    AtıfWoS27
    Web of Scienceİncele
  • MakaleAçık Erişim2013Scopus SJRQ4
    Effects of the Different Methacrylate Monomers on Bond Strength Between Soft Liner and Acrylic Resin

    Bolayir, Giray; Soygun, Koray; Simsek, Selcuk; Yilmaz, Ersen; Dogan, Arife; Boztug, Ali; Dogan, Orhan Murat

    In the present study, tensile bond strength between on acrylic resin and a soft liner, molloplast B, was studied. To enhance the bonding capacity between these materials, acrylic resin surface was modified using ethyl methacrylate, iso-butyl methacrylate or tert-butyl methacrylate monomers. The monomers were applied onto the surfaces of methacrylate components for 60, 120 or 180 s and the bond strength values were obtained. The values were statistically compared. Changes on the modified surfaces were investigated by fourier transform infared spectroscopy with attenuated total reflectance (FTIR-ATR). The highest bond strength value was obtained from 120 s treatments with ethyl methacrylate and the lowest value was obtained from 60 s treatments with iso-butyl methacrylate. These high alkyl monomers also had secondary interactions on the acrylic surfaces, evidenced by FTIR-ATR.

    AtıfOpenAlex1
    Web of Scienceİncele
  • MakaleAçık Erişim2013Scopus SJRQ3
    Mechanical and thermal properties of polyamide versus reinforced PMMA denture base materials

    Soygun, Koray; Bolayir, Giray; Boztug, Ali

    PURPOSE. This in vitro study intended to investigate the mechanical and thermal characteristics of Valplast, and of polymethyl methacrylate denture base resin in which different esthetic fibers (E-glass, nylon 6 or nylon 6.6) were added. MATERIALS AND METHODS. Five groups were formed: control (PMMA), PMMA-E glass, PMMA-nylon 6, PMMA-nylon 6.6 and Valplast resin. For the transverse strength test the specimens were prepared in accordance with ANSI/ADA specification No.12, and for the impact test ASTM D-256 standard were used. With the intent to evaluate the properties of transverse strength, the three-point bending (n=7) test instrument (Lloyd NK5, Lloyd Instruments Ltd, Fareham Hampshire, UK) was used at 5 mm/min. A Dynatup 9250 HV (Instron, UK) device was employed for the impact strength (n=7). All of the resin samples were tested by using thermo-mechanical analysis (Shimadzu TMA 50, Shimadzu, Japan). The data were analyzed by Kruskal-Wallis and Tukey tests for pairwise comparisons of the groups at the 0.05 level of significance. RESULTS. In all mechanical tests, the highest values were observed in Valplast group (transverse strength: 117.22 +/- 37.80 MPa, maximum deflection: 27.55 +/- 1.48 mm, impact strength: 0.76 +/- 0.03 kN). Upon examining the thermo-mechanical analysis data, it was seen that the E value of the control sample was 8.08 MPa, higher than that of the all other samples. CONCLUSION. Although Valplast denture material has good mechanical strength, its elastic modulus is not high enough to meet the standard of PMMA materials.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfWoS67OpenAlex110
    Web of Scienceİncele
Tam Kayıt
AlanDeğerDil
dc.date.accessioned2026-10-28T14:58:43.741695661Z
dc.date.available2026-10-28T14:58:43.741695661Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3948
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleBoztug, Ali
person.affiliation.nameTunceli Univ, Fac Engn, Dept Chem Engn, Tunceli, Turkey
person.familyNameBoztug
person.givenNameAli
person.statusunverified