Stripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode

MakaleYalnız künyeScopus SJRQ1

Özet

This study is related to the development of a highly sensitive and selective electrode for the electroanalysis of dicofol (DCF) by the modification of a glassy carbon electrode (GCE) with graphene (GR) nanosheets. GR was characterized by Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM), transmission electron microscopy (TEM), and electrochemical methods. The electrochemical reduction of DCF was observed on both bare GCE and GR-modified GCE (GRE). The electrochemical reaction of DCF on GRE was observed to be an adsorption controlled. Differential pulse stripping voltammetry was chosen in the electrochemical analysis of DCF, and two linear calibration ranges from 5.0 x 10(-8) to 5.0 x 10(-7) M and from 5.0 x 10(-7) to 4.2 x 10(-4) M were obtained with a low detection limit of 1.08 x 10(-7) M (N = 5) under the optimized experimental conditions. The electrode developed was successfully used to monitor dicofol in a series of spiked samples.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/4268Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11581-015-1407-1Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
6
OpenAlex
9
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKoçak, Berna
dc.contributor.authorEr, Engin
dc.contributor.authorÇelikkan, Huseyin
dc.date.accessioned2026-10-28T14:59:07.070115217Z
dc.date.available2026-10-28T14:59:07.070115217Z
dc.date.issued2015-08
dc.description.abstractThis study is related to the development of a highly sensitive and selective electrode for the electroanalysis of dicofol (DCF) by the modification of a glassy carbon electrode (GCE) with graphene (GR) nanosheets. GR was characterized by Fourier transform infrared spectroscopy (FTIR), atomic force microscopy (AFM), transmission electron microscopy (TEM), and electrochemical methods. The electrochemical reduction of DCF was observed on both bare GCE and GR-modified GCE (GRE). The electrochemical reaction of DCF on GRE was observed to be an adsorption controlled. Differential pulse stripping voltammetry was chosen in the electrochemical analysis of DCF, and two linear calibration ranges from 5.0 x 10(-8) to 5.0 x 10(-7) M and from 5.0 x 10(-7) to 4.2 x 10(-4) M were obtained with a low detection limit of 1.08 x 10(-7) M (N = 5) under the optimized experimental conditions. The electrode developed was successfully used to monitor dicofol in a series of spiked samples.
dc.description.sponsorshipTurkish Scientific and Technological Research Council [209T118]
dc.description.sponsorshipGazi University Scientific Research Fund [05/2010-05]
dc.identifier.doi10.1007/s11581-015-1407-1
dc.identifier.eissn1862-0760
dc.identifier.endpage2344
dc.identifier.issn0947-7047
dc.identifier.issue8
dc.identifier.startpage2337
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/4268
dc.identifier.volume21
dc.identifier.wosWOS:000358665100028
dc.language.isoen
dc.publisherSPRINGER HEIDELBERG
dc.relation.ispartofIONICS
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectGraphene
dc.subjectDicofol
dc.subjectStripping
dc.subjectVoltammetry
dc.subjectSensor
dc.subject.classificationChemistry, Physical
dc.subject.classificationElectrochemistry
dc.subject.classificationPhysics, Condensed Matter
dc.subject.classificationChemistry
dc.subject.classificationPhysics
dc.subject.otherPESTICIDES
dc.subject.otherNANOTUBES
dc.subject.otherSENSOR
dc.subject.otherWATER
dc.titleStripping voltammetric analysis of dicofol on graphene-modified glassy carbon electrode
dc.typeArticle
rdl.citation.openalex9
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)