Effect of Swirl Generator Inserted Into a Tube on Exergy Transfer: Decaying Flow

MakaleAçık ErişimScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji

Özet

This study experimentally investigates the effect of conical injector type swirl generator inserts on heat and exergy transfer in a uniform heat flux tube for turbulence regime. One hundred twenty watts of heat are applied by coiling a flexible silicone heater on the tube (copper pipe) with an inside diameter of 62mm and length of 1,200mm. The conical injector type swirl generator has a conical shape, which is similar to a funnel, with angle (alpha) of 30 degrees, 45 degrees, and 60 degrees. Circular holes are drilled on the conical injector type swirl generator as three different cross-sectional areas (A(h)). The total areas (A(t) =N.A(h)) of the holes on the conical injector type swirl generator equal each other. Because of this, the three different holes numbers (N) are produced. Flow directors having three different angles (beta=30 degrees, 60 degrees, and 90 degrees) to radial direction are attached to every one of the holes. This study is a typical example for decaying flow. Reynolds number (Re) was varied from 10,000 to 35,000, so the flow was considered as only a turbulent regime. All experiments were conducted with air accordingly; Prandtl number was approximately fixed at 0.71. The local and average heat transfer Nusselt number (Nu(h)) and exergy transfer Nusselt number (Nu(e)) are calculated and discussed in this article. It is found that the Nu(h) increases with an increase in Reynolds number, director angle (beta), and director diameter (d) but with a decrease in the conical injector type swirl generator angle (alpha). However, Nu(e) decreases depending on the same independent parameters.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/4666Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
12
OpenAlex
13
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKurtbas, I.
dc.contributor.authorGuelcimen, F.
dc.contributor.authorKiliçarslan, A.
dc.contributor.authorKaya, M.
dc.date.accessioned2026-10-28T15:03:35.905883605Z
dc.date.available2026-10-28T15:03:35.905883605Z
dc.date.issued2014-10
dc.description.abstractThis study experimentally investigates the effect of conical injector type swirl generator inserts on heat and exergy transfer in a uniform heat flux tube for turbulence regime. One hundred twenty watts of heat are applied by coiling a flexible silicone heater on the tube (copper pipe) with an inside diameter of 62mm and length of 1,200mm. The conical injector type swirl generator has a conical shape, which is similar to a funnel, with angle (alpha) of 30 degrees, 45 degrees, and 60 degrees. Circular holes are drilled on the conical injector type swirl generator as three different cross-sectional areas (A(h)). The total areas (A(t) =N.A(h)) of the holes on the conical injector type swirl generator equal each other. Because of this, the three different holes numbers (N) are produced. Flow directors having three different angles (beta=30 degrees, 60 degrees, and 90 degrees) to radial direction are attached to every one of the holes. This study is a typical example for decaying flow. Reynolds number (Re) was varied from 10,000 to 35,000, so the flow was considered as only a turbulent regime. All experiments were conducted with air accordingly; Prandtl number was approximately fixed at 0.71. The local and average heat transfer Nusselt number (Nu(h)) and exergy transfer Nusselt number (Nu(e)) are calculated and discussed in this article. It is found that the Nu(h) increases with an increase in Reynolds number, director angle (beta), and director diameter (d) but with a decrease in the conical injector type swirl generator angle (alpha). However, Nu(e) decreases depending on the same independent parameters.
dc.identifier.doi10.1080/08916152.2013.803175
dc.identifier.eissn1521-0480
dc.identifier.endpage487
dc.identifier.issn0891-6152
dc.identifier.issue5
dc.identifier.startpage472
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/4666
dc.identifier.volume27
dc.identifier.wosWOS:000334489300005
dc.language.isoen
dc.publisherTAYLOR & FRANCIS INC
dc.relation.ispartofEXPERIMENTAL HEAT TRANSFER
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectexergy transfer
dc.subjectheat transfer
dc.subjectswirl generator
dc.subject.classificationThermodynamics
dc.subject.classificationEngineering, Mechanical
dc.subject.classificationEngineering
dc.subject.otherPERFORMANCE EVALUATION CRITERIA
dc.subject.otherHEAT-TRANSFER SURFACES
dc.subject.otherENTROPY GENERATION
dc.subject.otherPRESSURE-DROP
dc.subject.otherTHERMODYNAMIC OPTIMIZATION
dc.subject.otherTHERMAL PERFORMANCE
dc.subject.otherEXCHANGER
dc.subject.otherMINIMIZATION
dc.subject.otherDUCTS
dc.titleEffect of Swirl Generator Inserted Into a Tube on Exergy Transfer: Decaying Flow
dc.typeArticle
rdl.citation.openalex13
rdl.citation.wos12
rdl.oa.statuspreprint
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/11491/1040
rdl.scopus.quartileQ1
rdl.sdgSDG07
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)