Sürdürülebilir Kalkınma Amaçları
Yayınları
20 →- MakaleYalnız künye2026Scopus SJRQ3Sensitive Electrochemical Analysis of Gentamicin Sulfate in Eye Solution
Ekşi, Osman; İpek, Yeliz; Koçak, Berna
In this study, for the first time, chromium (III) oxide-glutardialdehyde modified boron-doped diamond electrode (Cr2O3-GA2/BDDE) was used as a sensor for the electrochemical analysis of gentamicin sulfate. The Cr2O3-GA2 suspension used in electrode modification was physically coated on the BDD electrode by a simple drop-casting method. Characterization of Cr2O3-GA2 used in the modification was made by scanning electron microscopy, energy-dispersive spectroscopy (SEM-EDS), and the electrochemical method. The behavior of gentamicin sulfate on Cr2O3-GA2/BDDE was studied by cyclic voltammetry (CV), and its electrochemical analysis was done by differential pulse voltammetry (DPV). Electrochemical analysis of gentamicin sulfate on Cr2O3-GA2/BDDE was carried out in a pH 9 Britton–Robinson (BR) buffer by the DPV method. The linear working range of gentamicin sulfate on Cr2O3-GA2/BDDE was calculated as 5.96 × 10−6−6.54 × 10−5mol L−1, and the correlation coefficient was calculated as 0.997. The limit of detection (LOD) was found to be 2.84 × 10−6. mol L−1. Additionally, Genta, a 3% eye/ear drop solution, was preferred to determine the applicability of gentamicin sulfate in a commercial formulation. As a result, it was shown that the method developed on Cr2O3-GA2/BDDE for the determination of gentamicin sulfate can be applied to commercial drugs.
- MakaleAçık Erişim2026Scopus SJRQ2Electrochemical analysis of tetracycline in drug formulations with glutardialdehyde-Fe2O3 modified glassy carbon electrode
Koçak, Berna; İpek, Yeliz
In this study, a glutardialdehyde-Fe2O3 modified glassy carbon electrode (GA2–Fe2O3/GCE) was used as a sensor for the electrochemical analysis of tetracycline (TC) in drug formulations. The electrochemical behavior of TC on GA2-Fe2O3/GCE was investigated using cyclic voltammetry (CV), while the quantitative determination was performed via differential pulse voltammetry (DPV). After optimizing the experimental conditions, the linear working range, limit of (LOD) detection, and limit of quantification (LOQ) of the GA2-Fe2O3/GCE electrode developed for the electrochemical analysis of TC were found to be 1.0 × 10−6–2.0 × 10−5 M and 2.0 × 10−5–9.9 × 10−6 M; 4.78 × 10−7 M; 1.59 × 10−6 M, respectively. In the sensor application study conducted on a Tetra® Gensenta tablet to demonstrate the applicability of the developed method, the linear working range, LOD, and LOQ values of the sensor were found to be 1.0 × 10−6–14.8 × 10−5 M; 5.72 × 10−7 M and 1.74 × 10−6 M, respectively. The applicability of the method was demonstrated through tablet recovery studies, and the tablet recovery ratio was determined to be 100.94%.
- MakaleYalnız künye2026Scopus SJRQ2Synthesis of Aminothiophene derivative complexes and electrochemical sensor application for carbofuran pesticide
Taş, Abdurrahim; İpek, Yeliz; Adiguzel, Ragip
In this study, a ligand named 2-amino-6-ethyl-4,5,6,7-tetrahydrothieno[2,3-c]pyridine-3‑carbonitrile (ATL), which is an aminothiophene ligand, was synthesized. ATL was used to synthesize ATL-Co(II), ATL-Cu(II), and ATL-Zn(II) complexes. The chemical structures of the complexes were elucidated by spectroscopic methods such as FT-IR, UV–visible, and LC-MS analysis, as well as TG-DTA analysis, magnetic susceptibility measurements, and elemental analysis. Finally, the electrochemical characterization of ATL and the electrochemical sensor application of its complexes was performed. In electrochemical sensor studies, a carbofuran pesticide sensor application was investigated. ATL exhibited an irreversible oxidation peak around 1.0 V. It was observed that ATL-Co(II), ATL-Cu(II), and ATL-Zn(II) complexes behaved similarly to ATL and exhibited an irreversible oxidation peak at the same potential. Carbofuran pesticide was added to the sensor medium using the standard addition method. The changes in peak current with different carbofuran concentrations constituted the data of the amperometric sensor application, and the changes in the peak potential constituted the data of the voltammetric sensor application. Linear working ranges, LOD, and LOQ values were calculated for ATL, ATL-Co(II), ATL-Cu(II), and ATL-Zn(II) complexes, separately. The widest operating range as a voltammetric sensor was achieved with the ATL: 20 μmol L−1 to 350 μmol L−1. The lowest LOD and LOQ values were achieved with the ATL-Co(II) complex for voltammetric detection as 8.8 μmol L−1 and 29.2 μmol L−1, respectively. The lowest LOD and LOQ values were achieved with the ATL-Co(II) complex as 1.6 μmol L−1 and 5.2 μmol L−1 with the amperometric technique, respectively.
- MakaleYalnız künye2025Scopus SJRQ2Evaluation of Nano-Zinc Borate Effects on Thermal Properties, Morphology, Antibacterial Activity, and Drug Release Behavior of Starch/Gelatin Hydrogel Films for Biomedical Applications
Koçak, Berna; Gürler, Nedim; İpek, Yeliz; Yazdıç, Ferit Can; Karaman, Altuğ
Starch and gelatin offer opportunities for use due to their non-toxicity, biocompatibility, physical and functional properties. In this study, different amounts of nano-zinc borate were added to starch/gelatin composition for biological applications and their properties were studied. The structure of the films was investigated by various techniques. Nanostructured zinc borate was synthesized using a chemical method and particle sizes were determined as 196 nm. The atenolol drug was doped into the polymer composite. The atenolol release was performed at pH 7.4 and in phosphate-buffered saline solution medium. Cumulative drug release was 76% with the inclusion of nano-zinc borate in the polymer mixture. The atenolol release was approximately 50%–70% in films with nano-zinc borate added after 300 min. Furthermore, thermal resistance of the films improved with the addition of nano-zinc borate. The investigated chemical compound exhibited pronounced antibacterial activity against Gram-positive bacteria (Bacillus subtilis and Staphylococcus aureus), with significantly greater potency compared to Gram-negative bacteria (E. coli and Pseudomonas aeruginosa). Notably, the formulation containing 1.5% starch, 0.5% gelatin, and 1% nano-zinc borate demonstrated broad-spectrum efficacy against all tested pathogens, highlighting its potential as a promising antibacterial agent. The observed differential activity against bacterial strains suggests that fine-tuning the concentrations of starch, gelatin, and nano-zinc borate may optimize antibacterial efficacy and broaden the spectrum. The results showed us that non-toxic and biocompatible polymer films can be realized in pharmaceutical industry systems and biomedical applications.
- MakaleYalnız künye2025Scopus SJRQ2Highly sensitive DNA-based electrochemical biosensor for analysis of oseltamivir used in treatment of COVID–19
Keçeci, Ali; Koçak, Berna; İpek, Yeliz
Promising clinical results were obtained in the treatment of coronavirus disease by using favipiravir, umifenovir, remdesivir, ribavirin, lopinavir–ritonavir, oseltamivir, etc., antiviral drug active agents. In this study, quantitative analysis of oseltamivir neuraminidase inhibitor was carried out using electrochemical techniques. DNA-based electrochemical biosensors are generally used for analysis of anticancer and antitumor medicines. The present study introduces a novel DNA-based electrochemical sensor for neuraminidase inhibitor drug oseltamivir. The developed sensor enables the analysis of oseltamivir in a more environmentally friendly, more economical and faster way. It can be used in quality control laboratories in tablet production and will provide traceability of the drug in drug development studies and analysis in urine samples. For this purpose, a modified glassy carbon electrode was used as a working electrode. The glassy carbon electrodes alone cannot detect the oseltamivir. Guanine base, which was determined to interact with oseltamivir and found in the deoxyribonucleic acid structure, was used as an electrochemical biosensor agent. The guanine base was immobilized on glassy carbon electrode using glutardialdehyde as a crosslinker material and GA2–Guanine/GCE electrode was achieved. Two working ranges were determined for the Britton-Robinson buffer solution, tablet sample, and urine sample containing oseltamivir. The lowest detection limits (LODs) were calculated as 7.16 × 10−9 mol L−1, 9.05 × 10−9 mol L−1 and 6.19 × 10−6 mol L−1 for Britton-Robinson buffer solution, tablet sample solution, and urine sample solution, respectively. The recovery ratio for the proposed sensor ranged between 86.6 and 103.5%.
AtıfScopus3WoS3OpenAlex3İncele
- MakaleYalnız künye2025Scopus SJRQ3Eco-Friendly and Practical Electrochemical Determination of Lactic Acid in Milk Using Boron Doped Diamond Electrode
İpek, Yeliz.; Koçak, Berna; Keçeci, Ali
In this study, an economical, environmentally friendly, sensitive, selective, and rapid voltammetric quantitative analysis method was developed using a boron doped diamond electrode to determine lactic acid (LA). Two linear working ranges were determined for LA determination in phosphate buffer solution (PBS, pH of 2). The first linear working range (LR1) was between concentrations of 1.5 × 10−6–8 × 10−6 mol· L−1, with a detection limit of 1.3 × 10−6 mol·L−1, and the limit of quantification (LOQ) was found to be 4.4 µmol· L−1. The second linear working range (LR2) was determined in the concentration range of 8.0–89.2 µmol·L−1. LOD was calculated as 15.8 µmol·L−1, and the LOQ value was calculated as 52.6 µmol·L−1 in the LR2. Intraday repeatability of the BDD electrode for LA determination was (RSD) 6.8% in LR1 and 11.8% in LR2. The interday repeatabilities of the BDD electrode in LR1 and LR2 were calculated as 7.7% and 4.7%, respectively. The developed electrochemical sensor was successfully applied for the determination of LA in milk sample. The sensor exhibited a short response time of about 10 s in PBS at pH 2. The recovery values of LA in PBS and milk sample were 97.3% and 96.1%, respectively.
AtıfScopus2WoS2OpenAlex2İncele
- MakaleYalnız künye2025Scopus SJRQ3Cotton Fabric and Polypropylene Fabrics Treated with Synthesized Zinc Diborate
İpek, Yeliz; Ertekin, Özlem
Cotton fabrics and polypropylene fabrics are mostly used fabrics in many areas. Zn(B4O7) powder was synthesized with a sequential wet precipitation and sintering method. Focused ion beam scanning electron microscopy (FIB-SEM) figures and energy dispersive X-ray spectroscopy (EDS) mapping results showed that zinc diborate was highly and homogeneously adsorbed on the surface of the treated fabrics. When differential thermal analysis (DTA) results were examined, heat release seemed to decrease by 0.71 kJ g−1, 0.61 kJ g−1, and 0.46 kJ g−1for cotton fabric treated with zinc diborate (C-117-ZB), polypropylene fabric (20 g m−2) treated with zinc diborate (PP-20-ZB), and polypropylene fabric (65 g m−2) treated with zinc diborate (PP-65-ZB), respectively. According to vertical burning test, burning rates of cotton fabric (C‒117), C‒117‒ZB, polypropylene fabric (PP‒65), PP‒65‒ZB, polypropylene fabric (PP‒20), and PP‒20‒ZB were calculated as 3.25 cm s−1, 1.93 cm s−1, 0.75 cm s−1, 0.36 cm s−1, 0.88 cm s−1, and 0.71 cm s−1, respectively. Heat releases and burning rate decreases were in good agreement for all treated fabrics. Also breaking strengths of both fabric types were improved. The washing test exhibited that the amount of zinc diborate powder on the cotton fabric sample was released by 25.49% while PP-65-ZB and PP-20-ZB fabrics released about 90% by weight of adsorbed powder. Although improvement was observed in the fire resistance of PP fabrics, antibacterial activity against Escherichia coli and Staphylococcus aureus could not be achieved. However, antibacterial activity was provided only for the cotton fabric.
- MakaleYalnız künye2023Scopus SJRQ1Spatial dispersion hot spots of contamination and human health risk assessments of PTEs in surface sediments of streams around porphyry copper mine, Iran
Ipek, Yeliz; Kocak, Berna; Moussavi-Harami, Reza; Zand-Moghadam, Hamed; Mahboubi, Asadollah; Tohidi, Mohammad Reza
This comprehensive research has been conducted to consider the distribution of PTEs in the surface sediments of a recently developed Dar-e-Allo copper mine in dependence on the potential ecological and human health risks. Field sampling was carried out discreetly at preselected sampling spots including the natural background, the streams around the mine, waste rock drainages, evaporative deposits, sediments containing Fe oxy-hydroxides and secondary phases. Distribution of target elements (Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, S, Sb, Se, and Zn) showed high levels of crustal elements. As regards, Fe, Al, and S are identified to exist as the most copious elements in the earth's crust, so have the major portion of potentially toxic elements (PTEs) in the sediment concentrations. Evaluating environmental indices reflected that in general, Cu, S, and Mo have a higher quota of contamination in sedimentary systems. the pollution load index (PLI), modified contamination degree (mCd), Contamination factor (C-f), Sediment potential index (SPI), Geo-accumulation index (I-geo) and Contamination degree (C-d) confirm that sedimentary systems of mining area are heavily contaminated by PTEs and were not found within the guideline acceptable values. The potential ecological risk index (PERI) displayed a high or severe risk level for Cu with a peak in green-blue sediments containing secondary minerals. The results of total carcinogenic risk (TCRs) show that As has high toxicity level and carries a risk of carcinogenicity among children and adults. The TCRs for Cd, Cr, Ni, and Pb with carcinogenic potential are found only in children and they are classified as the prime concern elements that have serious dangers to children's public health. The results of contamination source presumed that the sources of PTEs contamination were principally geogenic along with the anthropogenic sources in the study area. Therefore, the present study has highlighted the implication of human health risks of PTEs in sedimentary systems of copper mining, also will grant advice for prime stakeholders, including mine managers, Environmental Protection Agency, the government and public organizations in connection to protecting the environment, aquatic biota and consumer's health.
AtıfWoS9OpenAlex11İncele
- MakaleAçık Erişim2023Scopus SJRQ3Anthocyanin based sensory pad for determination of chicken meat spoilage
Ipek, Y.; Ertekin, O.
Production and consumption of chicken meat has increased considerably with the increasing world population, and will continue to increase, due to its health benefits and its economic value. Chicken meat is a sensitive food due to its characteristics and microbiological load. Traceability is very important to increase food safety and biosecurity. Freshness indicators are often used to monitor the presence of metabolites produced by microorganisms, mostly functioning through the colour change of the indicator. A developed natural, edible, biodegradable, purple coloured pH sensitive sensory pad was put inside a chicken meat package to observe the chicken meat spoilage with colour change due to pH changes in the meat.
AtıfWoS1OpenAlex1İncele
- MakaleYalnız künye2023Scopus SJRQ3Nafion–Titanium (IV) Oxide-Graphene Modified Glassy Carbon Electrode (GCE) Based Electrochemical Sensor for the Voltammetric Determination of the β-blocker Bisoprolol Fumarate
Koçak, Berna; İpek, Yeliz
A Nafion–titanium (IV) oxide-graphene modified glassy carbon electrode (n-TiO2-GR/GCE) was used for the electrochemical determination of bisoprolol fumarate (BF). The modified electrode was prepared by depositing Nafion–titanium (IV) oxide-graphene onto the glassy carbon electrode by simple drop-casting. Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) were used in the electrochemical determination of bisoprolol fumarate. The linear working range of bisoprolol fumarate for n-TiO2-GR/GCE DPV was from 3.0 × 10−7 to 5.0 × 10−6mol L−1 and the detection limit was 1.01 × 10−7mol L−1. In addition, with this developed method, the determination of bisoprolol fumarate in tablets was successfully performed with a recovery of 98.65%.
AtıfScopus3WoS2OpenAlex3İncele
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.date.accessioned | 2026-10-28T14:36:51.085076077Z | |
| dc.date.available | 2026-10-28T14:36:51.085076077Z | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/munzur/521 | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.title | İpek, Yeliz | |
| person.affiliation.name | Tunceli Meslek Yüksekokulu, Kimya ve Kimyasal İşleme Teknolojileri Bölümü | |
| person.familyName | İpek | |
| person.givenName | Yeliz | |
| person.identifier.orcid | 0000-0002-9390-9875 | |
| person.identifier.wos | LZI-0666-2025 | |
| person.identifier.yok | 798A3D2AED99AC98 | |
| person.jobTitle | Doç. Dr. | |
| person.name.variant | İpek, Yeliz. | |
| person.name.variant | Ipek, Y. | |
| person.name.variant | Ipek, Yeliz | |
| person.name.variant | Ipek, Yeliz Koca | |
| person.status | verified | |
| person.url | https://akademik.yok.gov.tr/AkademikArama/AkademisyenGorevOgrenimBilgileri?islem=direct&authorId=798A3D2AED99AC98 |




