The effect of using phase change materials and examining the aspect ratio in an air-cooled system of a plate battery connected to a solar system

MakaleAçık Erişim
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

Lithium-ion batteries are widely used in the electronics industry to store electrical energy. One of the challenges with these batteries is that they heat up during operation, which can damage the battery. For this reason, this paper simulates the cooling process of a plate-type (BTP) lithium-ion battery pack. To control the temperature of the battery (T-B), a laminar air flow and a phase change material (PCM) are used. The PCM is placed in a heat sink around the battery. This evaluation is performed temporarily for four different dimensions of the PCM pack. The hot outlet of this system is used to provide the thermal energy required for a small residential building (THE) at a mild temperature. The BTP was also simulated using COMSOL. The results show that the use of larger heat sinks can increase the maximum (MAX) and average (AVE) temperature of the battery. The minimum T-B occurs at different times for the smaller PCM heat sinks. Also, when using a heatsink with a larger PCM volume, it takes longer for the PCM to fully solidify. A BTP with 5 or 50 battery cells can provide up to 3% or 30% of the THE required for the building.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/6511Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.21923/jesd.1106646Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
0
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAkkurt, Nevzat
dc.date.accessioned2026-10-28T15:11:42.474037140Z
dc.date.available2026-10-28T15:11:42.474037140Z
dc.date.issued2022
dc.description.abstractLithium-ion batteries are widely used in the electronics industry to store electrical energy. One of the challenges with these batteries is that they heat up during operation, which can damage the battery. For this reason, this paper simulates the cooling process of a plate-type (BTP) lithium-ion battery pack. To control the temperature of the battery (T-B), a laminar air flow and a phase change material (PCM) are used. The PCM is placed in a heat sink around the battery. This evaluation is performed temporarily for four different dimensions of the PCM pack. The hot outlet of this system is used to provide the thermal energy required for a small residential building (THE) at a mild temperature. The BTP was also simulated using COMSOL. The results show that the use of larger heat sinks can increase the maximum (MAX) and average (AVE) temperature of the battery. The minimum T-B occurs at different times for the smaller PCM heat sinks. Also, when using a heatsink with a larger PCM volume, it takes longer for the PCM to fully solidify. A BTP with 5 or 50 battery cells can provide up to 3% or 30% of the THE required for the building.
dc.identifier.doi10.21923/jesd.1106646
dc.identifier.eissn1308-6693
dc.identifier.endpage1211
dc.identifier.issue4
dc.identifier.startpage1194
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/6511
dc.identifier.volume10
dc.language.isoen
dc.relation.ispartofMühendislik Bilimleri ve Tasarım Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectNanobilim ve Nanoteknoloji
dc.subjectEnerji ve Yakıtlar
dc.titleThe effect of using phase change materials and examining the aspect ratio in an air-cooled system of a plate battery connected to a solar system
dc.typeArticle
rdl.citation.openalex0
rdl.citation.trdizin0
rdl.oa.statusgold
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/2387179
rdl.sdgSDG07
rdl.sdgSDG13
rdl.source.indexTRDIZIN