Numerical investigation of the effect of using louver baffles on thermal performance in solar air collectors

MakaleYalnız künyeScopus SJRQ2
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 13 · İklim Eylemi

Özet

Conventional flat plate solar air collectors have advantages such as low cost and simple design. However, their thermal efficiency is lower than that of other designs. The thermal efficiency of these collectors can be increased by detailed examination of parameters such as the shape, size, arrangement and material of the air duct. In this study, it is aimed to improve the thermal efficiency of solar air collectors. The effect of louver baffles, which were not previously used in solar air collectors, on thermal efficiency was investigated numerically via computational fluid dynamics. Three different solar air collectors with flat plates, segmented baffles, and louver baffles were compared in terms of thermal efficiency. In addition, pressure drops in solar air collectors were investigated. The mass flow rate of the air in all collectors is assumed to be 0.04 kg/s. Analyzes were carried out between 09:00 and 16:00. The thermal efficiency values obtained during the day for solar air collectors with flat plate, segmented baffles and louver baffles are 27.66%–56.35%, 29.57%–58.82% and 30.09%–59.47%, respectively. The daily thermal efficiency values obtained for solar air collectors with flat plate, segmented baffles and louver baffles are 46.98%, 49.18% and 49.87%, respectively. The pressure drop for solar air collectors with flat plate, segmented baffles and louver baffles were found to be 4.62, 18.82 and 5.96 Pa, respectively. Based on the data obtained from this study, louver baffles are recommended for use in solar heating applications due to their high thermal efficiency and low pressure drop.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2070Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/ep.14128Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
5
WoS
5
OpenAlex
5
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTuğan, Volkan
dc.contributor.authorIşık, Erdem
dc.date.accessioned2026-10-28T14:54:54.161114985Z
dc.date.available2026-10-28T14:54:54.161114985Z
dc.date.issued2023
dc.description.abstractConventional flat plate solar air collectors have advantages such as low cost and simple design. However, their thermal efficiency is lower than that of other designs. The thermal efficiency of these collectors can be increased by detailed examination of parameters such as the shape, size, arrangement and material of the air duct. In this study, it is aimed to improve the thermal efficiency of solar air collectors. The effect of louver baffles, which were not previously used in solar air collectors, on thermal efficiency was investigated numerically via computational fluid dynamics. Three different solar air collectors with flat plates, segmented baffles, and louver baffles were compared in terms of thermal efficiency. In addition, pressure drops in solar air collectors were investigated. The mass flow rate of the air in all collectors is assumed to be 0.04 kg/s. Analyzes were carried out between 09:00 and 16:00. The thermal efficiency values obtained during the day for solar air collectors with flat plate, segmented baffles and louver baffles are 27.66%–56.35%, 29.57%–58.82% and 30.09%–59.47%, respectively. The daily thermal efficiency values obtained for solar air collectors with flat plate, segmented baffles and louver baffles are 46.98%, 49.18% and 49.87%, respectively. The pressure drop for solar air collectors with flat plate, segmented baffles and louver baffles were found to be 4.62, 18.82 and 5.96 Pa, respectively. Based on the data obtained from this study, louver baffles are recommended for use in solar heating applications due to their high thermal efficiency and low pressure drop.
dc.identifier.articlenumbere14128
dc.identifier.doi10.1002/ep.14128
dc.identifier.eissn1944-7450
dc.identifier.issn1944-7442
dc.identifier.issue5
dc.identifier.scopus2-s2.0-85151934341
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2070
dc.identifier.volume42
dc.identifier.wosWOS:000962212800001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofEnvironmental Progress and Sustainable Energy
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCFD analysis
dc.subjectlouver baffle
dc.subjectsolar air collector
dc.subjectsolar heater
dc.subjectthermal efficiency
dc.subject.classificationGreen & Sustainable Science & Technology
dc.subject.classificationEngineering, Environmental
dc.subject.classificationEngineering, Chemical
dc.subject.classificationEnvironmental Sciences
dc.subject.classificationScience & Technology - Other Topics
dc.subject.classificationEngineering
dc.subject.classificationEnvironmental Sciences & Ecology
dc.subject.otherAir
dc.subject.otherCollector efficiency
dc.subject.otherComputational fluid dynamics
dc.subject.otherPassive solar
dc.subject.otherPressure drop
dc.subject.otherSolar heating
dc.subject.otherCFD analysis
dc.subject.otherFlat plate
dc.subject.otherLouver baffle
dc.subject.otherLow-costs
dc.subject.otherNumerical investigations
dc.subject.otherSimple++
dc.subject.otherSolar air collector
dc.subject.otherSolar heater
dc.subject.otherThermal Performance
dc.subject.otherThermal-efficiency
dc.subject.otherDrops
dc.titleNumerical investigation of the effect of using louver baffles on thermal performance in solar air collectors
dc.typeArticle
rdl.citation.openalex5
rdl.citation.scopus5
rdl.citation.wos5
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.sdgSDG07
rdl.sdgSDG13
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)