Influences of sample shape, voltage gradient, and electrode surface form on the exergoeconomic performance characteristics of ohmic thawing of frozen minced beef

MakaleAçık ErişimScopus SJRQ1
  • SDG 7 · Erişilebilir ve Temiz Enerji

Özet

In the present study, it was aimed to investigate the exergoeconomic performance of ohmic thawing (OT) system during the thawing of frozen minced meat (lean beef). The effects of the sample shape (X: 13 × 4 × 3 cm, Y: 13 × 6 × 2 cm, Z: cylinder with a height of 13 cm and diameter of 3.91 cm), electrode surface form (titanium foil with smooth surface, titanium electrode with needle-type surface and titanium electrode with pyramid-type surface), and voltage gradients (10, 13, and 16 V/cm) were investigated. Lower exergoeconomic values were obtained for the cylindrical shape compared to the rectangular prism. The lowest exergy efficiency value (12.45 ± 0.42), is was obtained for the cylindrical shape at 10 V/cm voltage gradient with titanium foil electrode. The needle-type surface electrodes had higher performance values than other electrodes. The exergoeconomic performance increased as the voltage gradient increased. The lowest unit exergy cost (72.40 ± 2.8) was obtained for rectangular prism shape at 16 V/cm with needle-type electrode. The comprehensive exergoeconomic evaluation in this study exhibited the energy utilization effectiveness and unit exergy cost of OT.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2982Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
32
WoS
28
OpenAlex
30
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇokgezme, Ömer Faruk
dc.contributor.authorDöner, Deniz
dc.contributor.authorÇevik, Mutlu
dc.contributor.authorKemahlıoğlu, Ali Varsın
dc.contributor.authorİçier, Filiz
dc.date.accessioned2026-10-28T14:56:04.227572288Z
dc.date.available2026-10-28T14:56:04.227572288Z
dc.date.issued2021
dc.description.abstractIn the present study, it was aimed to investigate the exergoeconomic performance of ohmic thawing (OT) system during the thawing of frozen minced meat (lean beef). The effects of the sample shape (X: 13 × 4 × 3 cm, Y: 13 × 6 × 2 cm, Z: cylinder with a height of 13 cm and diameter of 3.91 cm), electrode surface form (titanium foil with smooth surface, titanium electrode with needle-type surface and titanium electrode with pyramid-type surface), and voltage gradients (10, 13, and 16 V/cm) were investigated. Lower exergoeconomic values were obtained for the cylindrical shape compared to the rectangular prism. The lowest exergy efficiency value (12.45 ± 0.42), is was obtained for the cylindrical shape at 10 V/cm voltage gradient with titanium foil electrode. The needle-type surface electrodes had higher performance values than other electrodes. The exergoeconomic performance increased as the voltage gradient increased. The lowest unit exergy cost (72.40 ± 2.8) was obtained for rectangular prism shape at 16 V/cm with needle-type electrode. The comprehensive exergoeconomic evaluation in this study exhibited the energy utilization effectiveness and unit exergy cost of OT.
dc.description.sponsorshipTurkish Scientific and Technology Committee, (115O207)
dc.description.sponsorshipEge Üniversitesi
dc.description.sponsorshipTürkiye Bilimsel ve Teknolojik Araştirma Kurumu, TÜBITAK
dc.identifier.articlenumber110660
dc.identifier.doi10.1016/j.jfoodeng.2021.110660
dc.identifier.eissn1873-5770
dc.identifier.issn0260-8774
dc.identifier.scopus2-s2.0-85105328329
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2982
dc.identifier.volume307
dc.identifier.wosWOS:000655250000009
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofJournal of Food Engineering
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectEnergy
dc.subjectExergoeconomy
dc.subjectExergy
dc.subjectOhmic
dc.subjectThawing
dc.subject.classificationEngineering, Chemical
dc.subject.classificationFood Science & Technology
dc.subject.classificationEngineering
dc.subject.otherBeef
dc.subject.otherElectrodes
dc.subject.otherEnergy utilization
dc.subject.otherExergy
dc.subject.otherNeedles
dc.subject.otherPrisms
dc.subject.otherTitanium
dc.subject.otherElectrode surfaces
dc.subject.otherEnergy
dc.subject.otherExergoeconomics
dc.subject.otherExergoeconomy
dc.subject.otherOhmic
dc.subject.otherPerformance
dc.subject.otherSample shape
dc.subject.otherSurface forms
dc.subject.otherTitanium foils
dc.subject.otherVoltage gradient
dc.subject.otherThawing
dc.titleInfluences of sample shape, voltage gradient, and electrode surface form on the exergoeconomic performance characteristics of ohmic thawing of frozen minced beef
dc.typeArticle
rdl.citation.openalex30
rdl.citation.scopus32
rdl.citation.wos28
rdl.oa.statusgreen
rdl.oa.statuspreprint
rdl.oa.urlhttps://research.wur.nl/en/publications/influences-of-sample-shape-voltage-gradient-and-electrode-surface
rdl.scopus.quartileQ1
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)