Acrylamide concentrations in grilled foodstuffs of Turkish kitchen by high performance liquid chromatography-mass spectrometry

MakaleAçık ErişimScopus SJRQ2
  • SDG 2 · Açlığa Son

Özet

For over ten years, there has been a considerable interest in determination of acrylamide in foodstuffs. It was known that both protein-rich and carbohydrates-rich foods cooked at high-temperatures can cause acrylamide formation. However, carbohydrates-rich foods such as potato chips and biscuit samples have been the common studied foods compared with protein-rich foods such as meat samples. In this study, determination of acrylamide in these two group foods was examined using HPLC-MS. For this purpose, firstly, the parameters that are thought to affect the response in the HPLC-MS analysis were optimized. The optimized conditions were found to be 0.3 ml min(-1) for flow rate of mobile phase, 40 mu l for injection volume, 5 degrees C for column temperature and 70 V for fragmentor potential. The optimized method was applied for the determination of acrylamide levels in Turkish foodstuffs including grilled meat and chicken samples, potato chips, coffee and biscuit. The obtained concentrations for all studied foods were in the range of 20-250 mu g kg(-1). The results showed that acrylamide concentrations highly varied depending on the kind of food samples. (C) 2009 Elsevier B.V. All rights reserved.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/4266Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
WoS
36
OpenAlex
45
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKaplan, Olcay
dc.contributor.authorKaya, Gokce
dc.contributor.authorOzcan, Cemile
dc.contributor.authorInce, Muharrem
dc.contributor.authorYaman, Mehmet
dc.date.accessioned2026-10-28T14:59:06.829029100Z
dc.date.available2026-10-28T14:59:06.829029100Z
dc.date.issued2009-11
dc.description.abstractFor over ten years, there has been a considerable interest in determination of acrylamide in foodstuffs. It was known that both protein-rich and carbohydrates-rich foods cooked at high-temperatures can cause acrylamide formation. However, carbohydrates-rich foods such as potato chips and biscuit samples have been the common studied foods compared with protein-rich foods such as meat samples. In this study, determination of acrylamide in these two group foods was examined using HPLC-MS. For this purpose, firstly, the parameters that are thought to affect the response in the HPLC-MS analysis were optimized. The optimized conditions were found to be 0.3 ml min(-1) for flow rate of mobile phase, 40 mu l for injection volume, 5 degrees C for column temperature and 70 V for fragmentor potential. The optimized method was applied for the determination of acrylamide levels in Turkish foodstuffs including grilled meat and chicken samples, potato chips, coffee and biscuit. The obtained concentrations for all studied foods were in the range of 20-250 mu g kg(-1). The results showed that acrylamide concentrations highly varied depending on the kind of food samples. (C) 2009 Elsevier B.V. All rights reserved.
dc.identifier.doi10.1016/j.microc.2009.06.006
dc.identifier.eissn1095-9149
dc.identifier.endpage179
dc.identifier.issn0026-265X
dc.identifier.issue2
dc.identifier.startpage173
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/4266
dc.identifier.volume93
dc.identifier.wosWOS:000271847100010
dc.language.isoen
dc.publisherELSEVIER SCIENCE BV
dc.relation.ispartofMICROCHEMICAL JOURNAL
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAcrylamide
dc.subjectHPLC-MS
dc.subjectGrilled meat
dc.subjectPotato chips
dc.subjectChicken
dc.subject.classificationChemistry, Analytical
dc.subject.classificationChemistry
dc.subject.otherGAS-CHROMATOGRAPHY
dc.subject.otherMAILLARD REACTION
dc.subject.otherFRENCH FRIES
dc.subject.otherHEATED FOODS
dc.subject.otherPOTATO
dc.subject.otherMARKET
dc.subject.otherCOFFEE
dc.titleAcrylamide concentrations in grilled foodstuffs of Turkish kitchen by high performance liquid chromatography-mass spectrometry
dc.typeArticle
rdl.citation.openalex45
rdl.citation.wos36
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/11508/60837
rdl.scopus.quartileQ2
rdl.sdgSDG02
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)