Analysis of buildings in Tunceli - Pülümür district with the Canadian seismic screening method
Özet
This study, which was conducted in the P & uuml;l & uuml;m & uuml;r district of Tunceli, was carried out in an area with high seismic risk due to the region's proximity to the Bing & ouml;l-Yedisu Fault. In the study, the earthquake safety of the existing building stock was assessed using visual inspection methods. In this context, 172 buildings in the P & uuml;l & uuml;m & uuml;r district of Tunceli province were examined in detail in terms of earthquake safety using the Canadian Seismic Screening Method. In the analysis, seismic safety levels of the buildings, structural and nonstructural risks were taken into consideration and seismic priority indexes (SPI) were determined. The results of the study revealed that a large portion of buildings in the P & uuml;l & uuml;m & uuml;r district carry different levels of risk of earthquake. Specifically, the evaluated building stock was entirely constructed before the critical year of 2007 and exhibits high seismic vulnerability. This critical threshold is technically attributed to two main regional factors: the design practices predating the 2007 Turkish Earthquake Code and the absence of ready-mixed concrete technology in Tunceli province prior to that year. Furthermore, based on the method's classification, it is suggested that buildings with a Seismic Priority Index (SPI) greater than 20, which indicates High to Very Hazardous risk levels, should be prioritized for detailed assessment and retrofitting, and that local governments should develop incentive policies for these mitigation efforts.
Anahtar Kelimeler
- WoS
- 0
- OpenAlex
- 0
- TR Dizin
- 0
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Gundogdu, Yunus Emre | |
| dc.contributor.author | Polat, Berivan Yilmazer | |
| dc.date.accessioned | 2026-10-28T15:03:39.724013308Z | |
| dc.date.available | 2026-10-28T15:03:39.724013308Z | |
| dc.date.issued | 2026-06 | |
| dc.description.abstract | This study, which was conducted in the P & uuml;l & uuml;m & uuml;r district of Tunceli, was carried out in an area with high seismic risk due to the region's proximity to the Bing & ouml;l-Yedisu Fault. In the study, the earthquake safety of the existing building stock was assessed using visual inspection methods. In this context, 172 buildings in the P & uuml;l & uuml;m & uuml;r district of Tunceli province were examined in detail in terms of earthquake safety using the Canadian Seismic Screening Method. In the analysis, seismic safety levels of the buildings, structural and nonstructural risks were taken into consideration and seismic priority indexes (SPI) were determined. The results of the study revealed that a large portion of buildings in the P & uuml;l & uuml;m & uuml;r district carry different levels of risk of earthquake. Specifically, the evaluated building stock was entirely constructed before the critical year of 2007 and exhibits high seismic vulnerability. This critical threshold is technically attributed to two main regional factors: the design practices predating the 2007 Turkish Earthquake Code and the absence of ready-mixed concrete technology in Tunceli province prior to that year. Furthermore, based on the method's classification, it is suggested that buildings with a Seismic Priority Index (SPI) greater than 20, which indicates High to Very Hazardous risk levels, should be prioritized for detailed assessment and retrofitting, and that local governments should develop incentive policies for these mitigation efforts. | |
| dc.identifier.articlenumber | 651 | |
| dc.identifier.doi | 10.31462/jseam.2026.651 | |
| dc.identifier.eissn | 2630-5763 | |
| dc.identifier.endpage | 651 | |
| dc.identifier.issue | 2 | |
| dc.identifier.startpage | 651 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/munzur/4719 | |
| dc.identifier.volume | 9 | |
| dc.identifier.wos | WOS:001825454400001 | |
| dc.language.iso | en | |
| dc.publisher | GOLDEN LIGHT PUBL | |
| dc.relation.ispartof | JOURNAL OF STRUCTURAL ENGINEERING & APPLIED MECHANICS | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Earthquake | |
| dc.subject | Canadian seismic screening method | |
| dc.subject | Rapid visual assessment | |
| dc.subject | Yedisu fault | |
| dc.subject | P & uuml | |
| dc.subject | l & uuml | |
| dc.subject | m & uuml | |
| dc.subject | r | |
| dc.subject.classification | Construction & Building Technology | |
| dc.subject.classification | Engineering, Civil | |
| dc.subject.classification | Engineering | |
| dc.title | Analysis of buildings in Tunceli - Pülümür district with the Canadian seismic screening method | |
| dc.type | Article | |
| rdl.citation.openalex | 0 | |
| rdl.citation.trdizin | 0 | |
| rdl.citation.wos | 0 | |
| rdl.oa.status | bronze | |
| rdl.oa.url | https://doi.org/10.31462/jseam.2026.651 | |
| rdl.sdg | SDG11 | |
| rdl.sdg | SDG09 | |
| rdl.source.index | WOS | |
| rdl.source.index | TRDIZIN | |
| rdl.wos.index | Emerging Sources Citation Index (ESCI) |



