Sürdürülebilir Kalkınma Amaçları
Yayınlar
- MakaleYalnız künye2022Scopus SJRQ1Dynamic response model and equivalent solution method of large-diameter buried energy transportation pipeline under moving load
Xu, Qian; Yang, Gang; Li, Zhuorui; Zou, Zhenwei; Zheng, Qiang; Zhong, Liqiong; Chen, Xingli; Akkurt, Nevzat; Du, Yanping; Xiong, Yaxuan
Long-distance energy pipeline pass under roads, subjecting them to repeated stress and posing pipeline safety problems. To simulate the effects of vehicles driving over energy transmission pipeline, this paper examines large-caliber buried pipelines in the suburbs. In this study, a mechanical action model of vehicle-soil-pipeline (VSP) interactions to transform the process of a vehicle driving into the dynamic process of a load changing with time in the specified area was created. The VSP model was used to analyze the influence of moving load and position on the structural characteristics of the pipeline section. An equivalent solution method with high precision and high calculation efficiency was proposed. The results showed that as the loading position approaches the pipeline or the load increases, the stress value at the top of the pipeline gradually exceeded the stress value at the bottom of the pipeline and became the area with the maximum stress value. The minimum stress location also changed from the lower half near the pipeline bottom (Point D-135°) to the upper half near the pipeline top (Point B-45°or Point H-315°). Using the polynomial fitting method, the stress values of the maximum points were equivalently converted. Under the premise of considering pipeline safety, the most suitable functional relationship for the moving load equivalent model was obtained.
AtıfScopus16OpenAlex13İncele
- MakaleYalnız künye2022Scopus SJRQ1Numerical evaluation of the coupled/uncoupled effectiveness of a fluid-solid-thermal multi-field model for a long-distance energy transmission pipeline
Wang, Kang; Xie, Kai; Zhang, Hui; Qiang, Yujie; Du, Yanping; Xiong, Yaxuan; Zou, Zhenwei; Zhang, Mingbao; Zhong, Liqiong; Akkurt, Nevzat
As the main component of energy transmission, long-distance energy transmission pipeline (LETP), whose safety problem is becoming more and more prominent with the development of the oil and gas transportation industry, is susceptible to the traffic loading, temperature loading, pressure loading and other loadings. In this paper, the mechanical characteristics of LETP under the interaction of temperature loading and pressure loading are investigated. Based on the theory of multi-field coupling, the mathematical model of fluid-solid-thermal coupling of fluid-filled pipelines under the combined effect of temperature and pressure loadings is established and verified. Meanwhile, an equivalent model is proposed to accurately calculate the stress of any pipeline segment in LETP. The results show that the coupling of temperature loading and the pressure loading is significantly affected by the end-side constraints of the pipelines. For strong end-side constraint, the coupling effect of temperature and pressure loadings has a significant effect on the calculated equivalent stress. The difference between the stress solution under coupling effect and decoupling effect is above 30 MPa. However, for weak end-side constraints, the error is within 10 MPa. The equivalent stress can be approximated by the decoupling solution instead of the coupling solution.
AtıfScopus15OpenAlex15İncele
- MakaleYalnız künye2022Scopus SJRQ1Heat transfer performance by forced convection of microencapsulated phase change material-latent functional thermal fluid flowing in a mini-channels heat sink
Xu, Qian; Zhu, Lidong; Yan, Xinyu; Yang, Jingbin; Wang, Zhaoxiao; Liu, DingHai; Yang, Gang; Chen, Xingli; Akkurt, Nevzat; Liu, Lin
Conventional single-phase coolants have not been able to meet the high cooling requirements of electronic devices. Microencapsulated phase change material-latent functional thermal fluid (MPCM-LFTF), a solid–liquid two-phase cooling medium, has the dual advantages of active liquid cooling and passive phase change material cooling. However, it also increases the power consumption in the mini-channels, and the cooling efficiency of MPCM-LFTF in practical applications needs to be further studied. A new MPCM-LFTF was prepared by paraffin melamine resin MPCM and base fluid (absolute ethanol and deionized water) in this work. The heat transfer performance and hydrodynamic properties were investigated using the dimensionless wall temperature and friction factor, respectively. The efficiency factor was introduced to evaluate the cooling efficiency of MPCM-LFTF in mini-channels. The experimental results showed that the addition of MPCM increased the viscosity of MPCM-LFTF, which increased the friction factor. MPCM-LFTF with a mass fraction of 15 % had the best effect of temperature control and reduced the dimensionless wall temperature by 40.5 %. However, considering the characteristics of flow resistance and improved heat transfer, MPCM-LFTF with a mass fraction of 10 % had the highest cooling efficiency and the efficiency factor was 57.0 % higher than that of the base fluid.
AtıfScopus35OpenAlex36İncele
- MakaleYalnız künye2022Scopus SJRQ1Numerical evaluation of convective heat transfer properties of two-dimensional rotating PCM melt in the unilaterally heated rectangular container
Liu, Dinghai; Xie, Kai; Zhang, Hui; Qiang, Yujie; Yang, Di; Wang, Zhaoxiao; Zhu, Lidong; Akkurt, Nevzat; Du, Yanping; Shen, Meng
This paper carried out numerical investigations on the flow and heat transfer characteristics of a phase change with two-dimensional rotation of the three-dimensional paraffin (RT -27)-filled rectangular encapsulated container (PCM-REC) in space. A three-dimensional transient numerical heat transfer model was established and the enthalpy method was used to simulate the solid-liquid phase transition process and the flow evolution at the PCM interface. In this paper, the solid-liquid interface distribution, temperature distribution and melting time of PCM in PCM-REC heated at a constant temperature on one side were compared when rotated at different angles (0°, arctan (0.4), 2arctan (0.4) and 90°) along the heating direction and vertical heating direction. Results demonstrated that the peak value of maximum natural convection velocity increased from 0.0072 m/s to 0.0184 m/s with increasing radial height when PCM-REC was rotated in vertical heating direction. When PCM-REC was rotated in two dimensions by the same angle, the melting time was fastest when γ was an obtuse angle, and with the increase of the obtuse angle, the melting time shortened from 17 min to 6 min; when γ was an acute angle, the melting time was slowest, and with the decrease of the acute angle, the melting time lengthened from 49 min to 288 min.
AtıfScopus35OpenAlex40İncele
- MakaleAçık Erişim2022Scopus SJRQ1Experimental study on synergistic enhancement of thermal performance of a closed two-phase thermosyphon by a TiO2nanofluid doped with Al2O3
Xu, Qian; Yang, Gang; Jia, Shuhui; Wang, Zhaoxiao; Akkurt, Nevzat; Zhang, Hui; Zhou, Qiang; Shen, Meng; Yang, Di; Zhu, Lidong
The heat transfer performance of two-phase closed thermosyphon solar collectors (TPCTs) can be improved by adding nanoparticles to the conventional working fluid, but it is necessary to ensure good rheological properties while improving the heat transfer performance. Therefore, spherical (TiO2) nanoparticles with good rheological properties and rod-shaped (Al2O3) nanoparticles with high thermal conductivity were mixed and applied to the TPCT. First, the effects of individual factors such as the concentration of nanoparticles and the operating parameters on the thermal performance of the TPCT were investigated and a regression analysis was performed. Then, the joint effect of inclination angle and filling ratio on the thermal performance of TPCT was further investigated by orthogonal experiment. The results show that doping TiO2 with Al2O3 can further improve the thermal performance of TPCT. For the volume concentration of 0.6% of nanoparticles, filling ratio of 50% and inclination angle of 80°, the best heat transfer performance of TPCT was achieved. Compared with the deionized water (DW), the thermal resistance of the single (TiO2-H2O) and hybrid (Al2O3+TiO2-H2O) nanofluid TPCT is reduced by 10.7% and 13.4%, the thermal efficiency is increased by 11.0% and 13.7%, and the equivalent heat transfer coefficient is increased by 16.2% and 18.7%, respectively.
AtıfScopus38OpenAlex41İncele
- MakaleYalnız künye2021Scopus SJRQ1A new type of two-supply, one-return, triple pipe-structured heat loss model based on a low temperature district heating system
Xu, Qian; Wang, Kang; Zou, Zhenwei; Zhong, Liqiong; Akkurt, Nevzat; Feng, Junxiao; Xiong, Yaxuan; Han, Jingxiao; Wang, Jiulong; Du, Yanping
Based on the design concept of a fourth-generation smart pipe network system, this paper innovatively proposes a new TOTS (Two-supply/One-return, triple pipe structure) arrangement method for district heating systems. Moreover, to accurately predict the heat loss due to the pipeline operation of the multi-pipe system, based on the multipole calculation method, a new heat loss theoretical analytical model for the TOTS was created; additionally, a corresponding three-dimensional numerical simulation model was established, which was analyzed and numerically solved. The results showed that in comparison with thermal loss data measured by Danfoss et al., the above analytical and numerical models have a high accuracy, and the deviation is within 2%. Additionally, through calculations, it was found that the distance between the heating pipes is an important factor that affects the total heat loss from the new multi-control heating system and the actual heat exchange between pipes.
AtıfScopus74OpenAlex75İncele


