- MakaleAçık Erişim2026Scopus SJRQ2Examination of the thermal and metallographic characteristics at high temperatures of natural stones (andesite) extracted from different elevations
Işık, Erdem; Kahraman, Gökhan; Atalar, Aydın
This study examines the high‑temperature thermal response of andesite stones extracted from two different elevations of Mount Ağrı (Türkiye) in order to improve material selection strategies for engineering applications. Thermal conductivity and density values of the samples were first measured under laboratory conditions. The specimens were then heated to 850 °C and cooled by natural convection while surface temperatures were recorded at fixed time intervals using a thermal camera. Based on these measurements, convective heat transfer coefficients were determined, and the time‑dependent thermal diffusivity and Biot numbers were subsequently calculated using the first-term approximation of the Fourier series. Metallographic examinations were conducted to correlate the thermal behavior with microstructural characteristics. Results indicate a pronounced effect of elevation on thermal performance. The sample obtained from the higher elevation exhibited substantially greater thermal diffusivity, reaching 2.93 × 10⁻5 m2 s−1 at 360 s and decreasing to 8.96 × 10⁻6 m2 s−1 at 1300 s. In contrast, the lower‑elevation andesite showed lower diffusivity values (1.83 × 10⁻5 m2 s−1 at 360 s and 5.9 × 10⁻6 m2 s−1 at 1300 s). Conversely, Biot numbers were consistently higher for the lower‑elevation sample, decreasing from 0.60 to 0.29 during the cooling process, whereas the high‑elevation sample displayed values from 0.314 to 0.165. Metallographic analysis confirmed that variations in microstructure—linked to different geological formation conditions—directly influenced these thermophysical properties. Overall, the findings demonstrate that andesite sourced at higher elevations possesses superior thermal diffusivity and more favorable heat‑transfer characteristics at elevated temperatures. These results highlight the importance of geological origin in the design, assessment, and selection of natural stone materials for high‑temperature engineering applications.
- MakaleAçık Erişim2026Scopus SJRQ2Synergistic Effect of Cylindrical Fins and Phase Change Material on the Thermal and Economic Performance of a Double-Slope Solar Distillation Device Under Tunceli Climatic Conditions
Tuğan, Volkan; Işık, Erdem; İnallı, Mustafa
Global water scarcity driven by population growth, climate variability, and rising freshwater demand increases the need for more efficient solar desalination systems. In this study, a double-slope solar distillation device supported by a phase change material pool was developed to improve freshwater production. The phase change material layer was placed directly beneath the absorber plate to store excess thermal energy during peak solar radiation and release it during low-radiation periods. To strengthen thermal interaction between the absorber surface and the storage medium, cylindrical fins were embedded within the phase change material pool. The development of a double-slope solar distillation device integrated with a finned phase change material pool, and the simultaneous comparison of the thermal efficiency and economic analyses of single-slope and double-slope solar distillation devices under the same climatic conditions, are the prominent features of this study. Additionally, the performance of solar distillation devices has not previously been investigated under the climatic conditions of Tunceli, which further motivates this research. The developed system reached a peak freshwater productivity of 2459.2 g/m2/day, providing a 21.4% enhancement over the conventional configuration. In addition, the thermal efficiency increased from 17.7% in the conventional unit to 21.4% in the phase change material-assisted design. The economic analysis showed that the cost of distilled water was $0.097/kg for the conventional system and $0.105/kg for the proposed system, with the corresponding payback periods being approximately 11 and 12 months, respectively.
AtıfScopus2WoS2OpenAlex2İncele
- MakaleAçık Erişim2026Scopus SJRQ1Numerical analysis of PCM integrated in solar dryers for thermal efficiency
Bakır Gür, Eda; Işık, Erdem; Uçar, Aynur
Solar dryers using phase change materials buffer heat, yet the combined influence of airflow regime and PCM placement on melting remains underexplored. A controlled like-for-like study fixed geometry and PCM properties while varying placement and operating conditions. A 3D transient CFD model simulated a forced-convection dryer with RT28HC over Re = 3000–9000 and inlet temperatures Ti = 50–60 °C. Raising either Re or Ti shortened melt time, and three-wall coverage melted faster and more uniformly than a rear-wall-only layout. For three walls, melt time dropped from 13 h (50 °C, Re = 3000) to 7 h (60 °C, Re = 9000) (−46 %) for the rear wall it fell from 19 h to 11 h (−42 %). A 10 °C increase in Ti reduced overall melt time by 4 h across Re. Practically, three wall PCM with Re ≥ 6000 at Ti = 60 °C achieved reliably 7–9 h melting, enabling late afternoon heat release without auxiliary heating.
AtıfScopus17WoS16OpenAlex12İncele
- MakaleYayıncıda açık erişim2025Scopus SJRQ1Experimental analysis of a double-slope solar still integrated with parabolic trough solar collector using nanofluid
Tuğan, Volkan; İnallı, Mustafa; Işık, Erdem
The use of solar energy in the treatment of saline water offers a sustainable and low-cost solution to the increasing global fresh water demand. In this direction, solar still systems separate water vapor from saline water by directly using solar radiation and then condense it to obtain pure water. However, their fresh water productivity is relatively low. Therefore, in this study, the fresh water productivity and thermal efficiency of the double slope solar distillation unit integrated with parabolic trough solar collector, which operates completely on solar energy, were investigated experimentally. In addition, the effect of water-based nanofluid containing multi-walled carbon nanotubes on the performance of the solar still was investigated. All the stills produced were compared in terms of fresh water productivity and thermal efficiency. According to the results obtained from the study, the highest daily productivity was found to be 1963.8 g/m2/day, 2008.5 g/m2/day, 2592.0 g/m2/day and 2937.6 g/m2/day for SSSS, DSSS, PTSC integrated DSSS and both NF and PTSC integrated DSSS, respectively. It was observed that the daily productivity of DSSS, DSSS with integrated PTSC, and DSSS with both PTSC and NF were 6.6 %, 42.2 %, and 49.6 % higher than SSSS, respectively. Additionally, it was observed that the thermal efficiency of DSSS using PTSC and NF was lower compared to SSSS due to its larger system area.
AtıfScopus13WoS8OpenAlex10İncele
- MakaleAçık Erişim2025Scopus SJRQ3Experimental and Theoretical Study on the Freshwater Productivity of a Single-Slope Solar Still
Tuğan, Volkan; Işık, Erdem; İnallı, Mustafa
Converting saline water into freshwater using renewable energy resources is crucial to address global shortages of freshwater. This study aims to investigate the freshwater productivity of a single-slope solar still (SSS) operating with solar energy, one of the renewable energy sources. The main motivation of this study is to evaluate the experimental, theoretical, and economic performance of the solar still under climate conditions that have not been sufficiently studied before. Experimental analyses were conducted under the climatic conditions of Tunceli, a city located in the Eastern Anatolia Region of Türkiye. In addition, a comprehensive theoretical analysis was carried out using energy equations, and the experimental and theoretical results were compared with each other. Finally, the economic feasibility of the system was evaluated through a cost analysis. The SSS's experimental and theoretical productivity were found to be 1883.9 and 2458.7 g/m2/day, respectively. The experimental thermal efficiency for this still was 15.1%, whereas the theoretical thermal efficiency was 19.7%. It was concluded that the theoretical productivity and efficiency values were close to the experimental values and the difference between them originated from the assumptions of theoretical calculations. The cost of water distilled by the single-slope solar distillation unit was found to be $0.077/kg, and the payback period was found to be 9 months.
AtıfScopus2WoS3OpenAlex2İncele
- MakaleAçık Erişim2024Modeling changes in the quality attributes of couscous cooked with ohmic heating
Sabanci, Serdal; Işık, Erdem; Goksu, Ali; Omaç, Basrı
Kinetic studies on the quality alters of couscous are crucial to the suitable design of ohmic heating treatment. Hence, it was targeted to build mathematical models to forecast the changes in quality attributes of couscous cooked using ohmic heating (OH) in the present study. In addition, the average power and total energy for cooking couscous with OH at a voltage gradient of 17 V/cm were determined. Three dissimilar kinetic models—zero, first, and second—were fitted to the data. Our findings showed that, for the ohmic heating system, as cooking time increased, energy consumption increased while heating system efficacy declined. The best model to reflect the changes in color parameters was the second-order model, while the zero-order model best fit the experimental data observed for the cooking loss, moisture content, and weight increase (%). For all TPA parameters, however, neither model yielded the greatest fit.
AtıfOpenAlex1
İncele - MakaleAçık Erişim2024İklimlendirme Sistemlerinin (VRF-CHILLER KAZAN FCU) Seçimi ve Maliyet Analizi: Otel Örneği
Işık, Erdem; Bingöl, Abdullah
Mekanik sistemlerin tükettikleri enerjilerin, sistemlere bağlı yatırım maliyetlerinin ve işletme maliyetlerinin ekonomi üzerindeki etkisi tartışılmazdır. Özellikle Türkiye gibi enerji tüketimi yoğun olan ve iklim koşulları ülke genelinde sert olan ülkelerde yüksek maliyet kalemlerinden biri olan soğutma/ısıtma sistemlerine ayrılan maliyet önemli bir sorun olarak görülmektedir. Çözüme yönelik sistem seçimlerinde yatırım ve işletme maliyetleri öncelikli ölçüt olmaktadır. Teknolojinin gelişmesiyle birlikte çelik boruların, kazanların, chiller gruplarının ve vanaların yerini, paket halinde üretilmiş ve içerisinde soğutma çevrimini gerçekleştirerek ısı alan ve tersinir olarak çalışıp ısı veren VRF (değişken soğutucu akışkan akışı) sistemleri almıştır. Bu gelişme ekipmanları koruma altına almayı da kolaylaştırmıştır. Bu çalışmada Marmara bölgesinde yer alan 300 odalı bir otel esas alınarak, Kazan-Chiller-Fancoil sistemi ile VRF sistemi yatırım, yaz-kış işletme ve bakım maliyetleri ele alınarak kıyaslanmıştır. Sonuç olarak VRF sisteminin ilk yatırım maliyeti açısından yaklaşık olarak %16 daha dezavantajlıyken, yaz-kış işletme ve bakım maliyetleri ele alındığında yaklaşık olarak yıllık %14 daha avantajlıdır ve bu sayede bir yıl gibi kısa bir sürede yatırım maliyetini amorti ettiği hesaplanmıştır.
- MakaleYalnız künye2024Scopus SJRQ2Dynamic Analysis and Metallographic Examination of Linings with Different Composite Contents used in the Brakes of a Hydraulic Turbine
Işık, Erdem; Kahraman, Gökhan
The main aim of this study was to find ways to increase the performance and life of generator brake linings, which can lead to cost reduction and adequate downtime periods for hydroelectric power plants. First, the dynamic analysis of the linings used in hydraulic turbines was realized and their reactions were examined under different operating conditions. Second, two types of brake linings with different composite components produced in the market were examined metallographically and tested to determine both the stopping performance and durability time of the turbine-generator unit for a sufficient period of time in the vertical 150-megawatt Francis turbine with approximately 500 tons of rotary weight. As a result of these experiments, the lining with the boron component led to much better results than the other brake linings. It has been determined that the boron-containing lining makes 100 stops more than the other lining and stops 20 s earlier in one stop. Therefore, the use of a composite lining with boron content in the braking systems of hydroelectric power plants significantly reduces maintenance incidents and operation costs as it prolongs brake replacement periods in these plants. Graphical Abstract: (Figure presented.)
AtıfScopus1WoS1OpenAlex1İncele
- MakaleAçık Erişim2023Application of a new dynamic analysis method to pid controlled speed governors in hydroelectric power plants
Işık, Erdem; Kahraman, Gökhan
Hydroelectric power plants are environmental-friendly as they are renewable energy sources and make great contributions to the economies. In addition, they are in the state of insurance of the electricity network, since they can respond to the power demands of the electricity network in a very short time. In this study, the effect of the speed governors dispense valve has been added to the classical control mechanism in order to accurately predict the reaction of hydroelectric power plants to the load requirement of the electrical network. As a result of the dynamic analysis, the data obtained in the simulation environment have been compared with the responses of the real hydraulic turbine. The results show that when the dynamic analysis of the speed governor dispense valve is added to the classical control mechanism, the power response behavior in the simulation environment becomes closer to the real hydraulic turbine behavior. These results will assist speed governor designers in predicting real-like behavior in hydroelectric power plants.
- MakaleAçık Erişim2023The effect of ohmic heating on the quality properties of couscous during cooking
Sabanci, Serdal; Işık, Erdem; Goksu, Ali; Omaç, Basrı
Couscous has been widely eaten around the world because it has a low glycemic index, is low in fat, and is simple to prepare. However, it should be cooked before consumption. Therefore, novel heating methods, such as ohmic heating, can be used to cook couscous. This study aimed to investigate the potential use of ohmic heating at a voltage gradient of 17 V/cm to cook couscous and compare it with the conventional cooking method. To determine the effect of ohmic heating and conventional methods on the quality properties (color, texture profile analysis, cooking loss, moisture content, and weight increase (%)) of couscous, samples were cooked in a 0.1% salt solution. The samples were analyzed at different cooking times (4, 8, 12, and 16 min). The results obtained in the present study revealed that the total color difference also increased with an increase in cooking time. In addition, similar trends were observed for cooking loss, moisture content, and weight gain. Furthermore, the couscous samples treated with ohmic heating and conventional heating methods were completely cooked after 12 minutes. Overall, compared to the conventional cooking method, the ohmic heating process did not induce any negative effects on the quality parameters of couscous.
AtıfOpenAlex1TR Dizin1
İncele - MakaleAçık Erişim2023Theoretical and Practical Investigation of Stability Performance for Power Regulation in Hydroelectric Power Plants
Kahraman, Gökhan; Işık, Erdem
Hydroelectric power plants are the insurance of the interconnected system in order to provide fast energy to the system compared to other fossil fueled power plants. Hydroelectric power plants control the balance between the energy it supplies to the interconnected system and the pressurized water it uses with a system based on the fully automatic control principle. The quality of the energy supplied to the interconnected system depends entirely on this automatic control mechanism. In this study, mathematical models of the mechanisms that affect the automatic control system during the generation of energy in hydroelectric power plants are formed. Transfer functions of the obtained mathematical models are calculated by laplace transform. With the calculated transfer functions, the responses of the units of a hydroelectric power plant to the change of the amount of energy produced under different operating conditions are determined. The obtained data are compared with the actual conditions in a 1330 MW hydroelectric power plant with 8 Francis turbines. It is seen that the mathematical model and the turbine responses in real conditions are similar. In the calculations made at 115, 125, 135, 145 m. net head, the best stability conditions were obtained at 135 m. In addition, as a result of the calculations obtained under different operating conditions, ideal operating conditions are determined to minimize the fluctuations in energy production.
AtıfScopus2OpenAlex2
İncele - MakaleYalnız künye2023Scopus SJRQ2Numerical investigation of the effect of using louver baffles on thermal performance in solar air collectors
Tuğan, Volkan; Işık, Erdem
Conventional flat plate solar air collectors have advantages such as low cost and simple design. However, their thermal efficiency is lower than that of other designs. The thermal efficiency of these collectors can be increased by detailed examination of parameters such as the shape, size, arrangement and material of the air duct. In this study, it is aimed to improve the thermal efficiency of solar air collectors. The effect of louver baffles, which were not previously used in solar air collectors, on thermal efficiency was investigated numerically via computational fluid dynamics. Three different solar air collectors with flat plates, segmented baffles, and louver baffles were compared in terms of thermal efficiency. In addition, pressure drops in solar air collectors were investigated. The mass flow rate of the air in all collectors is assumed to be 0.04 kg/s. Analyzes were carried out between 09:00 and 16:00. The thermal efficiency values obtained during the day for solar air collectors with flat plate, segmented baffles and louver baffles are 27.66%–56.35%, 29.57%–58.82% and 30.09%–59.47%, respectively. The daily thermal efficiency values obtained for solar air collectors with flat plate, segmented baffles and louver baffles are 46.98%, 49.18% and 49.87%, respectively. The pressure drop for solar air collectors with flat plate, segmented baffles and louver baffles were found to be 4.62, 18.82 and 5.96 Pa, respectively. Based on the data obtained from this study, louver baffles are recommended for use in solar heating applications due to their high thermal efficiency and low pressure drop.
AtıfScopus5WoS5OpenAlex5İncele
- MakaleAçık Erişim2023Scopus SJRQ3Impact of electron concentration on the transformation temperature and important physical properties of NiMnSnFe ferromagnetic shape memory alloys
Malkoç, Türkan; Kanca, Muhammed Sait; Işık, Erdem; Kök, Mediha
This study aimed to explore the influence of electron concentration on the NiMnSn alloy, which is a crucial ferromagnetic shape memory alloy (FSMA). The alloy was doped with various amounts of iron element to assess its effect. According to DSC measurement, iron doping has resulted in a general decrease in the transformation temperature value of NiMnSn alloy, as well as a decrease in the transformation enthalpy value. The orthorhombic martensite phase of NiMnSn alloy was replaced by L21 austenite crystal structure in X-ray measurements. Martensite, austenite, and precipitate phases were observed in SEM images. Iron doping significantly increased the magnetic saturation value of NiMnSn alloy, according to magnetic measurements, and thermomagnetic measurements revealed similar results. Graphical Abstract: [Figure not available: see fulltext.]
AtıfScopus5WoS5OpenAlex5İncele
- MakaleAçık Erişim2021Çiçek Tip Şaşırtma Levhasına Sahip Gövde Borulu Isı Değiştiricinin CFD Analizi
Işık, Erdem; Tuğan, Volkan
Gövde borulu ısı değiştiricilerinin ısıl ve hidrolik performansını etkileyen en önemli faktörlerden bir tanesi şaşırtma levhasıdır. Bu çalışmada, ANSYS Fluent programı aracılığıyla, çiçek tip şaşırtma levhasına sahip gövde borulu ısı değiştiricinin CFD analizi yapılmıştır. Analizlerde, çiçek tip şaşırtma levhasının gövde tarafı ısı taşınım katsayısına, basınç düşüşüne ve basınç düşüşü başına düşen ısı transfer oranına etkisini araştırmak amaçlanmıştır. Ek olarak, çiçek tip şaşırtma levhası ile geleneksel tek parçalı şaşırtma levhası karşılaştırılmıştır. Tasarlanan gövde borulu ısı değiştiricinin gövde tarafında çalışma akışkanı olarak su kullanılmıştır. Analizlerde, gövde tarafındaki akışkan için dört farklı kütlesel debi (1.2 kg s-1, 1.5 kg s-1, 1.8 kg s-1 ve 2.1 kg s-1) incelenmiştir. Çalışmadan elde edilen sonuçlara göre, çiçek tip şaşırtma levhasının geleneksel tek parçalı şaşırtma levhasına göre basınç düşüşü başına düşen ısı transfer oranını artırdığı gözlemlenmiştir.
AtıfOpenAlex2TR Dizin1
İncele - MakaleAçık Erişim2021Dairesel Bir Boruda Kullanılan Boyuna Dalgalı Kanatçıkların Isı Transferine Etkisinin Sayısal Olarak İncelenmesi
Işık, Erdem; Tuğan, Volkan
Boruların dış yüzeyine yerleştirilen kanatçıklar ısı transferini önemli ölçüde etkilemektedir. Bu çalışmada, boyunadalgalı kanatçıkların ısı transferine etkisini araştırmak amacıyla içerisinden ısı transfer akışkanı olarak suyun aktığıdairesel bir borunun üç boyutlu akış analizi gerçekleştirilmiştir. Dairesel boruda 1 mm kalınlığa sahip 18 adet boyuna düzve boyuna dalgalı bakır kanatçıklar kullanılmıştır. Kanatçık tipine göre kütlesel debiyle ısı transferinin değişiminiincelemek için 0,1 kg s⁻¹, 0,14 kg s⁻¹, 0,18 kg s⁻¹ ve 0,22 kg s⁻¹ olmak üzere dört farklı kütlesel debi kullanılmıştır. Eldeedilen sonuçlara göre, boyuna dalgalı kanatçıkların boyuna düz kanatçıklara kıyasla ısı transferini en düşük %8, en yüksek%11 oranında arttırdığı gözlemlenmiştir.
AtıfOpenAlex5TR Dizin2
İncele - MakaleAçık Erişim2021Numerical Investigation of the Effect of Using Nanofluids on Thermal Performance in an Energy Storage Pipe
Bayrak, Fatih; Işık, Erdem; Uçar, Aynur; Bakır, Eda
Considering the advances in technology, new approaches and heatsinks with good thermal performance are needed to achieve the efficiency and reliability expected from high-efficiency electronic devices. In this numerical study, an aluminum pipe with the same hydraulic diameter, channel length and cross-section geometry was used. To increase the heat transfer rate of the system; Al2O3/water nanofluids with water, 1% and 2% concentrations were used in the pipe, and a 5mm thick RT25HC phase change material (PCM) was used on the outer surface of the pipe. The fluids passed through the aluminum pipe were analyzed using the ANSYS 20.2 package program at four different speeds and four different Reynolds numbers. According to the results obtained, the mass melting ratio and Nusselt number were calculated for each fluid. When the results obtained from the study were examined, it was seen that the best Nusselt and liquid fraction was Reynolds 1500 and 2% Al2O3/water. For all refrigerants, it was concluded that the mass melting rate of the refrigerants and the Nusselt number increased with the increase of the fluid velocity.
- MakaleYalnız künye2021Scopus SJRQ3Investigation of the effect of baffle cut on heat transfer and pressure drop in shell-and-tube heat exchangers using CFD
Işık, Erdem; Tuğan, Volkan
The shell-and-tube heat exchanger (STHE) is one of the most widely used types of heat exchangers in industry. For this reason, studies conducted to improve the performance of STHEs are of great importance. In this study, a single-shell- and double-tube-pass STHE was designed, and a three-dimensional and steady-state flow analysis of this heat exchanger was conducted using the CFD method. The purpose of the analysis was to investigate the effect of baffle cut and mass flow rate of the fluid on the shell side on heat transfer and pressure drop by using the ANSYS Fluent, which is a type of computational fluid dynamics (CFD) software. For this aim, oil and water are used as working fluids in the shell and tubes of the STHE, respectively. Four different mass flow rates (0.6 kg/s, 0.8 kg/s, 1.0 kg/s, and 1.2 kg/s) are used for the fluid in the shell. In the analysis, three different STHEs with baffle cuts of 20%, 30%, and 40% are compared. According to the results of the CFD analysis, baffle cut plays an important role in heat transfer and pressure drop. The highest heat transfer per pressure drop was achieved for the STHE with 40% baffle cut and the lowest was achieved for the STHE with 20% baffle cut.
AtıfScopus13WoS8OpenAlex11İncele
- Derleme MakaleAçık Erişim2019Scopus SJRQ2ANN and ANFIS Approaches to Calculate the Heating and Cooling Degree Day Values: The Case of Provinces in Turkey
Işık, Erdem; İnallı, Mustafa; Celik, Erkan
Energy analysis plays a vital role in developing an optimum and cost-effective design for the heating, ventilating and air conditioning system of a building. The values of heating degree days (HDD) and cooling degree days (CDD) are used to analyze the demand for energy for buildings. In this study, the HDD and CDD values for Turkey were calculated using estimated temperature values. An artificial neural network (ANN) and an adaptive network-based fuzzy inference system (ANFIS) were applied for the estimation of temperature values. The Levenberg–Marquardt training algorithm was used for the feedforward backpropagation of the ANN, whereas the Sugeno-type fuzzy inference system was used for the ANFIS. Meteorological data from the last 11 years were used for the proposed approaches, and these were applied to different stations (n = 50) of the Turkish State Meteorological Service. In relation to the insulated building design, base temperatures have been considered as 16 °C and 18 °C for the HDD and 22 °C and 24 °C for the CDD based on a literature review. Two novel maps were prepared for the CDD and HDD. The calculated degree days and the maps are consistent with those from the Turkish State Meteorological Service.
AtıfScopus13WoS13OpenAlex18İncele
- MakaleAçık Erişim2018Scopus SJRQ1Artificial neural networks and adaptive neuro-fuzzy inference systems approaches to forecast the meteorological data for HVAC: The case of cities for Turkey
Işık, Erdem; Inallı, Mustafa
Limited energy resources and increasing need for energy due to population growth seem to lead researchers to focus on these issues. Forecast of meteorological data has significant importance in design of thermal systems. In this study, forecasting of meteorological data used in thermal system design was performed for fifty cities to represent the entire Turkey. Data obtained from General Directorate of Meteorology (MGM) were modelled by artificial neural networks and adaptive-network based fuzzy inference systems. Matlab software was used for modeling and forecasting of prospective data with high sensitivity in thermal systems. Surfer and ArcGIS software were used to create humidity, temperature, solar radiation maps for Turkey. Root mean square error (RMSE), mean absolute error and (MAE), coefficient of variation (COV) and the coefficient of determination (R2) were used to validate the result of the proposed approaches. The results were satisfactory with respect to RMSE, MAE, COV and R2 to forecast the meteorological data. Annual solar power potential maps for Turkey were also proposed and compared with MGM results. The results of the proposed approaches are compatible with the result of the MGM. The Turkey policy maker(s) from MGM can easily use these approaches if a software is constructed.
AtıfScopus66WoS52OpenAlex68İncele
- MakaleYalnız künye2017Linyit Yakılan Bir Güç Üretim İstasyonunun Gaz Türbininin İkinci Kanun Analizi
Işık, Erdem; Gök, Mehmet; Berent, Hasan Kaan
Türkiye'nin linyit rezervlerin in büyük çoğunluğu, kalori değerinin düşük olması sebebiyle ancak termik santral yakıtı olarak kullanılmaya elverişlid ir. Bununla beraber, Türkiye'de ki en yaygın enerji kaynaklarından olan linyit reze rvle rin in uzun vadeli kullanımı; ucuz, te miz, verimli ve güvenilir yakma te knolojile rin in ku llan ımı ile mü mkündür. Mühendislik sistemlerinde ekserji analizinin uygulan ması; sistemlerin ilk tasarımı ve ekono mik analizlerinin yapılması açısından önemli veriler sunmaktadır. Analiz so nuçlarının değerlendirilmesi ile yapılan yorum ve enerji kayıpların ın yeri, büyüklüğü ve nedenleri saptanabilmekte, do layısıyla sistemlerin verimleri arttırılab ilmektedir. Çalışmamızda linyit yakıtını kullanan mevcut termik santraline, termod inamiğ in ikinci kanununa göre analiz yapılmıştır. Çalışmada sistemi o luşturan santral elemanlarından türbin için faydalı güç, tersinir güç ve tersinmezlik miktarları tespit edilmiş ve sistemin genel verimi hesaplanmıştır. Elde edilen sonuçlar ve değerlendirmelerde, termik santrallerin kuru lmasında ve işletilmesinde, tasarım ve ekonomi açısından önemli veriler bulundurmaktadır. Böylece günümüzde büyük önem taşıyan, enerji tasarrufu ve enerjinin en verimli şekilde kullanılması sağlanabilecektir
AtıfTR Dizin1