Modeling changes in the quality attributes of couscous cooked with ohmic heating

MakaleAçık Erişim
  • SDG 2 · Açlığa Son

Özet

Kinetic studies on the quality alters of couscous are crucial to the suitable design of ohmic heating treatment. Hence, it was targeted to build mathematical models to forecast the changes in quality attributes of couscous cooked using ohmic heating (OH) in the present study. In addition, the average power and total energy for cooking couscous with OH at a voltage gradient of 17 V/cm were determined. Three dissimilar kinetic models—zero, first, and second—were fitted to the data. Our findings showed that, for the ohmic heating system, as cooking time increased, energy consumption increased while heating system efficacy declined. The best model to reflect the changes in color parameters was the second-order model, while the zero-order model best fit the experimental data observed for the cooking loss, moisture content, and weight increase (%). For all TPA parameters, however, neither model yielded the greatest fit.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/6308Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.54365/adyumbd.1473698Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
1
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSabanci, Serdal
dc.contributor.authorIşık, Erdem
dc.contributor.authorGoksu, Ali
dc.contributor.authorOmaç, Basrı
dc.date.accessioned2026-10-28T15:11:29.097899030Z
dc.date.available2026-10-28T15:11:29.097899030Z
dc.date.issued2024
dc.description.abstractKinetic studies on the quality alters of couscous are crucial to the suitable design of ohmic heating treatment. Hence, it was targeted to build mathematical models to forecast the changes in quality attributes of couscous cooked using ohmic heating (OH) in the present study. In addition, the average power and total energy for cooking couscous with OH at a voltage gradient of 17 V/cm were determined. Three dissimilar kinetic models—zero, first, and second—were fitted to the data. Our findings showed that, for the ohmic heating system, as cooking time increased, energy consumption increased while heating system efficacy declined. The best model to reflect the changes in color parameters was the second-order model, while the zero-order model best fit the experimental data observed for the cooking loss, moisture content, and weight increase (%). For all TPA parameters, however, neither model yielded the greatest fit.
dc.identifier.doi10.54365/adyumbd.1473698
dc.identifier.eissn2149-0309
dc.identifier.endpage231
dc.identifier.issue23
dc.identifier.startpage216
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/6308
dc.identifier.volume11
dc.language.isoen
dc.relation.ispartofAdıyaman Üniversitesi Mühendislik Bilimleri Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectGıda Bilimi ve Teknolojisi
dc.titleModeling changes in the quality attributes of couscous cooked with ohmic heating
dc.typeArticle
rdl.citation.openalex1
rdl.citation.trdizin0
rdl.oa.statusbronze
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/3885816
rdl.sdgSDG02
rdl.source.indexTRDIZIN