Sürdürülebilir Kalkınma Amaçları

  • MakaleAçık Erişim2013Scopus SJRQ4
    Effects of the Different Methacrylate Monomers on Bond Strength Between Soft Liner and Acrylic Resin

    Bolayir, Giray; Soygun, Koray; Simsek, Selcuk; Yilmaz, Ersen; Dogan, Arife; Boztug, Ali; Dogan, Orhan Murat

    In the present study, tensile bond strength between on acrylic resin and a soft liner, molloplast B, was studied. To enhance the bonding capacity between these materials, acrylic resin surface was modified using ethyl methacrylate, iso-butyl methacrylate or tert-butyl methacrylate monomers. The monomers were applied onto the surfaces of methacrylate components for 60, 120 or 180 s and the bond strength values were obtained. The values were statistically compared. Changes on the modified surfaces were investigated by fourier transform infared spectroscopy with attenuated total reflectance (FTIR-ATR). The highest bond strength value was obtained from 120 s treatments with ethyl methacrylate and the lowest value was obtained from 60 s treatments with iso-butyl methacrylate. These high alkyl monomers also had secondary interactions on the acrylic surfaces, evidenced by FTIR-ATR.

    AtıfOpenAlex1
    Web of Scienceİncele
  • MakaleAçık Erişim2013Scopus SJRQ3
    Mechanical and thermal properties of polyamide versus reinforced PMMA denture base materials

    Soygun, Koray; Bolayir, Giray; Boztug, Ali

    PURPOSE. This in vitro study intended to investigate the mechanical and thermal characteristics of Valplast, and of polymethyl methacrylate denture base resin in which different esthetic fibers (E-glass, nylon 6 or nylon 6.6) were added. MATERIALS AND METHODS. Five groups were formed: control (PMMA), PMMA-E glass, PMMA-nylon 6, PMMA-nylon 6.6 and Valplast resin. For the transverse strength test the specimens were prepared in accordance with ANSI/ADA specification No.12, and for the impact test ASTM D-256 standard were used. With the intent to evaluate the properties of transverse strength, the three-point bending (n=7) test instrument (Lloyd NK5, Lloyd Instruments Ltd, Fareham Hampshire, UK) was used at 5 mm/min. A Dynatup 9250 HV (Instron, UK) device was employed for the impact strength (n=7). All of the resin samples were tested by using thermo-mechanical analysis (Shimadzu TMA 50, Shimadzu, Japan). The data were analyzed by Kruskal-Wallis and Tukey tests for pairwise comparisons of the groups at the 0.05 level of significance. RESULTS. In all mechanical tests, the highest values were observed in Valplast group (transverse strength: 117.22 +/- 37.80 MPa, maximum deflection: 27.55 +/- 1.48 mm, impact strength: 0.76 +/- 0.03 kN). Upon examining the thermo-mechanical analysis data, it was seen that the E value of the control sample was 8.08 MPa, higher than that of the all other samples. CONCLUSION. Although Valplast denture material has good mechanical strength, its elastic modulus is not high enough to meet the standard of PMMA materials.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfWoS67OpenAlex110
    Web of Scienceİncele