Sürdürülebilir Kalkınma Amaçları

  • MakaleYalnız künye2023Scopus SJRQ1
    Analysis of the mechanical behavior and prediction of the plastic zone of a large-diameter buried gas pipeline under ground overload

    Xu, Qian; Zhong, Liqiong; Shu, Mengjie; Zou, Zhenwei; Yang, Gang; Zheng, Qiang; Chen, Xingli; Akkurt, Nevzat; Zhang, Hui; Qiang, Yujie

    Plastic failure of pipelines caused by ground overload is increasing. The one-dimensional model based on mechanical nodal parameters cannot predict the plastic failure characteristics of the three-dimensional structure of the pipeline. In order to predict the evolution of the plastic failure of the pipeline with the yield strength as the evaluation criterion, a multidimensional model is needed to consider the changes in the external loads and the changes in the mechanical properties of the pipeline along the circumferential and axial directions. In this study, a finite element calculation model for a large-diameter gas pipeline underground overload was established to investigate the law of stress change in the plastic zone. The nonlinear surface fitting method was used to establish the angle fitting model of the plastic zone and the depth fitting model of the plastic zone. The variation of the area of the plastic zone was described, and the reliability of the results was verified. In addition, the accuracy of the fitting model and the cost of the finite element calculation were evaluated. The results showed that the pipeline entered plasticity at a ground load of P = 25 MPa, and the plastic zone developed continuously in the axial and circumferential directions as the ground load increased. The angle and depth increased to 36° and 1.8 m, respectively, at P = 50 MPa. The average absolute errors for the plastic zone depth fitting model and the plastic zone angle fitting model were 6.42% and 6.64%, respectively, both of which can provide an accurate description of the plastic zone. The calculation results of the plastic zone angle fitting model could meet requirements of data processing and analysis. The plastic zone depth fitting model could be used to obtain solutions with higher accuracy, but it increases the cost of finite element simulation.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus6OpenAlex6
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2023Scopus SJRQ1
    Analysis of the mechanical characteristics and plasticity-hazardous zones development of natural gas pipeline under overload

    Zheng, Qiang; Shu, Zekai; Yang, Gang; Zhang, Hui; AKKURT, Nevzat; Guan, Ben; Chen, Weiwang; Xu, Qian; Zang, Yong; Ding, Yulong

    The problem of natural gas pipeline overload failure is of great significance, and the development law of critical mechanical properties of pipelines is of great importance to the safety design of natural gas pipelines. This study establishes a three-dimensional finite element computational model of the pipeline that integrates the changes in axial and circumferential mechanical characteristics, and uses the yield strength, safety factor and ellipticity indexes as criteria to dimensionless the axial depth and circumferential angle of the plastic zone to explore the characteristics of the plastic damage stage of the pipeline. By solving the plastic hazardous zones based on the safety factor, the applicability of the dimensionless parameters is extended to investigate the development laws of the hazardous zones and the correlation mechanism between failure criteria and hazardous zones. The results show that as the ground load increases, the pipeline deformation gradually develops into the plastic stage (P = 16 MPa) and then goes through three deformation stages. With the increase of safety factor, the change trend of the proportion of stage I in the whole loading process decreases to 4 %, the change trend of the proportion of stage III increases significantly to 52 %, while the proportion of stage II shows a change trend of decreasing and then increasing, the proportion of this stage ranges from 30 % to 38 %. Based on the law of variation of axial ellipticity of pipeline section, a high-risk section of pipeline was identified in the range of 0–2 m from the point of maximum local compression strain. The results of the study can serve as a basis for accurate evaluation of the safety status of natural gas pipelines under overload.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus3WoS3OpenAlex3
    ScopusWeb of Scienceİncele
  • Derleme MakaleYalnız künye2023Scopus SJRQ1
    A review of advances in mechanical behaviors of the underground energy transmission pipeline network under loads

    Zheng, Qiang; Xu, Qian; Shu, Zekai; Yang, Di; Chen, Weiwang; Akkurt, Nevzat; Zhang, Hui; Lin, Lin; Zhang, Xinxin; Ding, Yulong

    The safety of underground energy transmission pipeline network is threatened by traffic, earthquakes, explosions, and other stresses. To solve the problem of damage to the underground energy transmission pipeline networks by external loads, this study analyzed the mechanical properties of the Pipe-Soil Coupling System (PSCS) under external loads from a mechanical perspective. The pipeline constitutive model, the soil constitutive model, the internal effect of the PSCS, the influence of external stresses on the PSCS, and the dynamic response of the PSCS under various research methodologies were all studied. First, different mechanical features of the pipes and soil were employed to investigate the pipe and soil constitutive models. Second, based on the different force directions within the PSCS, the earth pressure and axial friction of the PSCS were investigated to clarify the interaction between the pipe and soil. For the purpose of to better understand the degradation of the underground pipeline state, the impacts of man-made and natural stresses on the PSCS failure were explored. Finally, the results of the investigation of the dynamic response of the PSCS were examined for their applicability using three research methods: theoretical analysis, numerical simulation, and experimental analysis. It is found that the existing constitutive models of pipeline and soil are lack of basis, which increases the difficulty of the selection of constitutive models in the process of research. In the analysis of load effect, earth pressure plays a dominant role in affecting the local stability of pipeline, but the calculation accuracy of soil pressure needs to be improved. Due to the lack of experimental guidance for complex damage phenomena under external loads, it is impossible to accurately determine the limit state parameters of pipelines under complex damage modes. It is critical to create and refine the theory underpinned by numerous experimental data in order to address the issue of pipeline dynamic response under multi-field coupling, including explosion and earthquake. This work is critical for analyzing existing research findings, identifying future research problems, and enhancing buried pipeline safety management.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus15WoS13OpenAlex14
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2023Scopus SJRQ1
    A study on the combustion performance and NOx emissions characteristics of a novel U-type radiant tube based on MILD combustion theory

    Fan, Huanbao; Feng, Junxiao; Bai, Wei; Wang, Hui; Akkurt, Nevzat; Li, Weidong; Gao, Jun; AliAkbaria, Omid; Xu, Qian

    Based on the theory of moderate or intense low-oxygen dilution (MILD) combustion, a 3D steady-state CFD model coupling dual flue gas recirculation and dispersion combustion was developed to describe the flow field, combustion temperature field, wall temperature distribution, and NOx concentration field during the operation of a novel U-type radiant tube (N-URT). A user-defined function (UDF) method was implemented to simulate the dilution of O2 concentration in the combustion air due to external flue gas recirculation (E-FGR). The effects of the E-FGR ratio on combustion characteristics and NOx emission were evaluated. The simulated results were consistent with experimental results. The simulated NOx concentration at the outlet was reduced to 105.5 mg/m3 at 8% O2, which was about 35.2% lower than the conventional combustion method. The study found that when the E-FGR ratio was increased from 0 to 25%, the standard deviation of wall temperature decreased from 30.3 °C to 23.3 °C, and the non-uniformity coefficient decreased from 0.2598 to 0.2183, indicating an improvement in temperature uniformity. However, the thermal efficiency decreased from 82.1% to 76.2%. Moreover, at higher E-FGR ratios, the volume of the high-temperature region (above 1500 ℃) gradually decreased, and both the maximum flame temperature and the outlet NOx concentration decreased sharply. Regression equations for the E-FGR ratio (β) on the maximum combustion temperature (Tmax) and the outlet NOx concentration (CNOx) were obtained, and an E-FGR ratio greater than 13.4% was recommended to meet the emission requirements.

    AtıfScopus14OpenAlex14
    ScopusWeb of Scienceİncele
  • DüzeltmeYalnız künye2023Scopus SJRQ1
    Corrigendum to “A study on the combustion performance and NOx emissions characteristics of a novel U-type radiant tube based on MILD combustion theory” [Fuel 346 (2023) 128321] (Fuel (2023) 346, (S0016236123009341), (10.1016/j.fuel.2023.128321))

    Fan, Huanbao; Feng, Junxiao; Bai, Wei; Wang, Hui; Akkurt, Nevzat; Li, Weidong; Gao, Jun; AliAkbaria, Omid; Xu, Qian

    The authors regret to inform that Table 1 in the final (citable) version of our article [Fuel 346 (2023) 128321] published in Fuel has a serious error; some key data in Table 1 (page 4, Section 2.2) corresponded incorrectly to variables. This was mainly due to our carelessness and was not caught in time while reviewing proofs for our publications. The correction is necessary to improve the academic accuracy of the article and for ease of reference for the readers. We are therefore publishing this correction. Specifically, the pre-exponential factor Ar and activation energy Ea of 2CO + O2 → 2CO2 should be 2.239 × 1012 1/s and 1.7 × 108 J/kg·mol, respectively. The pre-exponential factor Ar and activation energy Ea of 2H2 + O2 → 2H2O should be 9.87 × 108 1/s and 3.1 × 107 J/kg·mol, respectively. Thank you for your understanding and the previous efforts of all the reviewers and editors. Reference [1] Huanbao Fan, Junxiao Feng, Wei Bai, Hui Wang, Nevzat Akkurt, Weidong Li, Jun Gao, Omid AliAkbaria, Qian Xu, A study on the combustion performance and NOx emissions characteristics of a novel U-type radiant tube based on MILD combustion theory, Fuel 346 (2023) 128321. DOI: https://doi.org/10.1016/j.fuel.2023.128321. The correct version of Table 1 is as follows: The authors would like to apologise for any inconvenience caused.

  • MakaleYalnız künye2023Scopus SJRQ1
    Carbide slag recycling to fabricate shape-stable phase change composites for thermal energy storage

    Xiong, Yaxuan; Wang, Huixiang; Ren, Jing; Nevzat, Akkurt; Xu, Qian; Nie, Binjian; Li, Chuan; Ding, Yulong

    The mining and processing of traditional skeleton materials inevitably generates carbon emissions and pollutes the surrounding environment. To make full use of industrial solid waste, this work innovatively used carbide slag as skeleton material and Na2CO3 as phase change material (PCM) to fabricate shape-stable phase change composites (SSPCCs) via the cold-compression & hot-sintering method. Seven SSPCCs were fabricated with different mass ratios of carbide slag to Na2CO3. Then, the thermal energy storage (TES) performance, mechanical property, micromorphology, chemical compatibility as well as thermal cycling stability were investigated. The results showed that the carbide slag could combine with Na2CO3 to fabricate SSPCCs; Sample CN5 achieved the optimal performance with the mass ratio 52.5:47.5 of carbide slag to Na2CO3; Sample CN5 achieved a TES density of 993 J/g in the range of 100 to 900 °C, a compressive strength of 22.02 MPa and a maximal thermal conductivity of 0.62 W/(m·K); Both carbide slag and Na2CO3 were distributed uniformly in sample CN5, while good thermal stability after the 100 heating/cooling cycles and good chemical compatibility between the carbide slag components and the Na2CO3 were observed.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 12 · Sorumlu Üretim ve Tüketim
    • SDG 13 · İklim Eylemi
    AtıfScopus34OpenAlex30
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2023Scopus SJRQ1
    Heat loss optimization and economic evaluation of a new fourth generation district heating triple pipe system

    Chen, Xingli; Ren, Ling; Zheng, Qiang; Yang, Gang; Akkurt, Nevzat; Liu, Lin; Liu, Zhiwei; Qiang, Yujie; Yang, Huachao; Xu, Qian

    In response to the heat loss caused by the temperature difference between the heating pipes and external environment during the pipe transportation, heat contradiction between the total heat loss of the piping system and heat transfer between tubes, as well as economic balance between the cost of heat loss and cost of material loss. Based on TOTS (Two-supply/One-return, triple pipe structure) heat loss theory of the fourth-generation district heating system, this paper optimizes structure of pipes by setting dimensionless characteristic parameters θ and β. Finally, a mathematical model is proposed to calculate economic efficiency of pipeline network by considering the cost of initial construction material loss and operation heat loss of the pipe. Results show that, from energy perspective, comprehensive heat as system energy consumption evaluation index is positively correlated with θ, decreases first and then increases as β increases. Total heat loss of system dominates comprehensive heat. Lowest comprehensive heat of system is 18.12 w/m for θ of 0.1945 and β of 0.0739. From economic perspective, total system loss cost as system economic evaluation index is positively correlated with both θ and β. Total system heat loss cost dominates total system loss cost. Lowest total system loss cost is $29.39/m for θ of 0.1945 and β of 0.0509.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus16OpenAlex20
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ1
    Dynamic response model and equivalent solution method of large-diameter buried energy transportation pipeline under moving load

    Xu, Qian; Yang, Gang; Li, Zhuorui; Zou, Zhenwei; Zheng, Qiang; Zhong, Liqiong; Chen, Xingli; Akkurt, Nevzat; Du, Yanping; Xiong, Yaxuan

    Long-distance energy pipeline pass under roads, subjecting them to repeated stress and posing pipeline safety problems. To simulate the effects of vehicles driving over energy transmission pipeline, this paper examines large-caliber buried pipelines in the suburbs. In this study, a mechanical action model of vehicle-soil-pipeline (VSP) interactions to transform the process of a vehicle driving into the dynamic process of a load changing with time in the specified area was created. The VSP model was used to analyze the influence of moving load and position on the structural characteristics of the pipeline section. An equivalent solution method with high precision and high calculation efficiency was proposed. The results showed that as the loading position approaches the pipeline or the load increases, the stress value at the top of the pipeline gradually exceeded the stress value at the bottom of the pipeline and became the area with the maximum stress value. The minimum stress location also changed from the lower half near the pipeline bottom (Point D-135°) to the upper half near the pipeline top (Point B-45°or Point H-315°). Using the polynomial fitting method, the stress values of the maximum points were equivalently converted. Under the premise of considering pipeline safety, the most suitable functional relationship for the moving load equivalent model was obtained.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus16OpenAlex13
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ1
    Numerical evaluation of the coupled/uncoupled effectiveness of a fluid-solid-thermal multi-field model for a long-distance energy transmission pipeline

    Wang, Kang; Xie, Kai; Zhang, Hui; Qiang, Yujie; Du, Yanping; Xiong, Yaxuan; Zou, Zhenwei; Zhang, Mingbao; Zhong, Liqiong; Akkurt, Nevzat

    As the main component of energy transmission, long-distance energy transmission pipeline (LETP), whose safety problem is becoming more and more prominent with the development of the oil and gas transportation industry, is susceptible to the traffic loading, temperature loading, pressure loading and other loadings. In this paper, the mechanical characteristics of LETP under the interaction of temperature loading and pressure loading are investigated. Based on the theory of multi-field coupling, the mathematical model of fluid-solid-thermal coupling of fluid-filled pipelines under the combined effect of temperature and pressure loadings is established and verified. Meanwhile, an equivalent model is proposed to accurately calculate the stress of any pipeline segment in LETP. The results show that the coupling of temperature loading and the pressure loading is significantly affected by the end-side constraints of the pipelines. For strong end-side constraint, the coupling effect of temperature and pressure loadings has a significant effect on the calculated equivalent stress. The difference between the stress solution under coupling effect and decoupling effect is above 30 MPa. However, for weak end-side constraints, the error is within 10 MPa. The equivalent stress can be approximated by the decoupling solution instead of the coupling solution.

    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus15OpenAlex15
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ1
    Heat and mass transfer mechanism and control strategy of clean low carbon combustion technology in the novel-type coke oven flue with MILD combustion

    Xu, Qian; Shen, Meng; Xie, Kai; Zhang, Hui; Akkurt, Nevzat; Wang, Jiulong; Xiong, Yaxuan; Shi, Kejian; Chen, Xingli; Lv, Qian

    In the field of emission reduction, considering the limitations of single clean combustion technology and joint control of carbon emission, the application of Technology of Mixed-Gas (TMG), Technology of Low-calorific Value Gas (TLVG) and Technology of Low Oxygen Combustion (TLOC) in the Novel-type Coke Oven Flue with MILD Combustion (MILD-NCOF) was realized. By adjusting the ratio of coke oven gas to blast furnace gas (α), the ratio of flue gas to gas (β) and the ratio of flue gas to air (γ), the heat and mass transfer mechanism of combustion process in MILD-NCOF was researched, the dual emission control system and the regulation strategy of pollutant and carbon emissions were established. The results showed that with the increase of α, β and γ, the fluidity of gas and the reaction rate of combustible components in the fire path were improved, the heat and mass transfer was enhanced, and the effect of dual emission reduction of pollutants and carbon emissions was improved. When the mixing ratio α was 0.6, Tave was reached at 1594.93 K. The NOx concentration at the outlet was 116.34 mg/m3, and the sum of the molar concentrations of CO and CO2 at the outlet was reduced to 1.440 × 10−1. When the mixing ratio β was 2.4, Tave was reached at 1518.73 K, the NOx concentration at the outlet was 128.42 mg/m3, and the sum of the molar concentrations of CO and CO2 at the outlet was 1.127 × 10−1. When the mixing ratio γ was 0.6, Tave was reached at 1627.28 K, the NOx concentration at the outlet was 142.73 mg/m3, and the sum of the molar concentrations of CO and CO2 was reduced to 1.128 × 10−1, which could meet the dual standards of clean production and low-carbon environmental protection of MILD-NCOF.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 13 · İklim Eylemi
    AtıfScopus30OpenAlex36
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ1
    Heat transfer performance by forced convection of microencapsulated phase change material-latent functional thermal fluid flowing in a mini-channels heat sink

    Xu, Qian; Zhu, Lidong; Yan, Xinyu; Yang, Jingbin; Wang, Zhaoxiao; Liu, DingHai; Yang, Gang; Chen, Xingli; Akkurt, Nevzat; Liu, Lin

    Conventional single-phase coolants have not been able to meet the high cooling requirements of electronic devices. Microencapsulated phase change material-latent functional thermal fluid (MPCM-LFTF), a solid–liquid two-phase cooling medium, has the dual advantages of active liquid cooling and passive phase change material cooling. However, it also increases the power consumption in the mini-channels, and the cooling efficiency of MPCM-LFTF in practical applications needs to be further studied. A new MPCM-LFTF was prepared by paraffin melamine resin MPCM and base fluid (absolute ethanol and deionized water) in this work. The heat transfer performance and hydrodynamic properties were investigated using the dimensionless wall temperature and friction factor, respectively. The efficiency factor was introduced to evaluate the cooling efficiency of MPCM-LFTF in mini-channels. The experimental results showed that the addition of MPCM increased the viscosity of MPCM-LFTF, which increased the friction factor. MPCM-LFTF with a mass fraction of 15 % had the best effect of temperature control and reduced the dimensionless wall temperature by 40.5 %. However, considering the characteristics of flow resistance and improved heat transfer, MPCM-LFTF with a mass fraction of 10 % had the highest cooling efficiency and the efficiency factor was 57.0 % higher than that of the base fluid.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    AtıfScopus35OpenAlex36
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2022Scopus SJRQ1
    Numerical evaluation of convective heat transfer properties of two-dimensional rotating PCM melt in the unilaterally heated rectangular container

    Liu, Dinghai; Xie, Kai; Zhang, Hui; Qiang, Yujie; Yang, Di; Wang, Zhaoxiao; Zhu, Lidong; Akkurt, Nevzat; Du, Yanping; Shen, Meng

    This paper carried out numerical investigations on the flow and heat transfer characteristics of a phase change with two-dimensional rotation of the three-dimensional paraffin (RT -27)-filled rectangular encapsulated container (PCM-REC) in space. A three-dimensional transient numerical heat transfer model was established and the enthalpy method was used to simulate the solid-liquid phase transition process and the flow evolution at the PCM interface. In this paper, the solid-liquid interface distribution, temperature distribution and melting time of PCM in PCM-REC heated at a constant temperature on one side were compared when rotated at different angles (0°, arctan (0.4), 2arctan (0.4) and 90°) along the heating direction and vertical heating direction. Results demonstrated that the peak value of maximum natural convection velocity increased from 0.0072 m/s to 0.0184 m/s with increasing radial height when PCM-REC was rotated in vertical heating direction. When PCM-REC was rotated in two dimensions by the same angle, the melting time was fastest when γ was an obtuse angle, and with the increase of the obtuse angle, the melting time shortened from 17 min to 6 min; when γ was an acute angle, the melting time was slowest, and with the decrease of the acute angle, the melting time lengthened from 49 min to 288 min.

    AtıfScopus35OpenAlex40
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2022Scopus SJRQ1
    Experimental study on heat transfer properties of gravity heat pipes in single/hybrid nanofluids and inclination angles

    Wang, Zhaoxiao; Zhang, Hui; Yin, Lei; Yang, Di; Yang, Gang; Akkurt, Nevzat; Liu, Dinghai; Zhu, Lidong; Qiang, Yujie; Yu, Fan

    In order to meet the working requirements of heat pipes under complex working conditions and high heat flux density, and propose corresponding thermal management solutions. In this paper, the single and hybrid nanofluids (TiO2-H2O, Al2O3-H2O, Al2O3+TiO2-H2O) with mass fraction of 5% under the gradient of gravity heat pipe at 50°, 60°, 70°, 80°, 90° are studied. The changes in thermal resistance, thermal efficiency and equivalent heat transfer coefficient of water were compared with deionized water. The results are as follows: The overall efficiency of gravity heat pipe ranges from 70% to 85%. Compared with deionized water, the nanofluid can effectively improve the heat transfer. At different inclination angles, the hybrid nanofluid with the same mass fraction shows the reverse trend compared with the single nanofluid by decreasing the thermal resistance of the heat pipe and increasing the heat transfer efficiency. At an inclination angle of 70°, the heat transfer efficiency of the nanofluid Al2O3+TiO2-H2O is 6.8% weaker compared to TiO2-H2O and 4.5% weaker compared to Al2O3-H2O. At a tilt angle of 60°, the heat transfer capacity of Al2O3+TiO2-H2O nanofluid increases by 7.3% compared to TiO2-H2O and by 5.6% compared to Al2O3-H2O.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    AtıfScopus47OpenAlex45
    ScopusWeb of Scienceİncele
  • MakaleAçık Erişim2022Scopus SJRQ1
    Experimental study on synergistic enhancement of thermal performance of a closed two-phase thermosyphon by a TiO2nanofluid doped with Al2O3

    Xu, Qian; Yang, Gang; Jia, Shuhui; Wang, Zhaoxiao; Akkurt, Nevzat; Zhang, Hui; Zhou, Qiang; Shen, Meng; Yang, Di; Zhu, Lidong

    The heat transfer performance of two-phase closed thermosyphon solar collectors (TPCTs) can be improved by adding nanoparticles to the conventional working fluid, but it is necessary to ensure good rheological properties while improving the heat transfer performance. Therefore, spherical (TiO2) nanoparticles with good rheological properties and rod-shaped (Al2O3) nanoparticles with high thermal conductivity were mixed and applied to the TPCT. First, the effects of individual factors such as the concentration of nanoparticles and the operating parameters on the thermal performance of the TPCT were investigated and a regression analysis was performed. Then, the joint effect of inclination angle and filling ratio on the thermal performance of TPCT was further investigated by orthogonal experiment. The results show that doping TiO2 with Al2O3 can further improve the thermal performance of TPCT. For the volume concentration of 0.6% of nanoparticles, filling ratio of 50% and inclination angle of 80°, the best heat transfer performance of TPCT was achieved. Compared with the deionized water (DW), the thermal resistance of the single (TiO2-H2O) and hybrid (Al2O3+TiO2-H2O) nanofluid TPCT is reduced by 10.7% and 13.4%, the thermal efficiency is increased by 11.0% and 13.7%, and the equivalent heat transfer coefficient is increased by 16.2% and 18.7%, respectively.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    AtıfScopus38OpenAlex41
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2021Scopus SJRQ2
    Effect of the Mixing Structure Parameters of a Self-reflux Burner on Combustion Characteristics and NOx Emission

    Xu, Qian; Shen, Meng; Shi, Kejian; Liu, Zhihui; Akkurt, Nevzat; Xiong, Yaxuan; Liu, Lin; Feng, Junxiao; Wang, Jiulong

    To solve the problem of low efficiency of NOx emission reduction in self-reflux burners, this study is based on the concept of coordinated control of self-reflux burner structural and thermal parameters. After completing the structural design and optimization of thermal parameters, we continue to adjust the two key structural parameters: the nozzle axis distance and the length of the cylindrical section, to minimize NOx emissions. These are the two parameters that chiefly affect the mixing of flue gas and fuel gas. The results show that increasing nozzle axis distance can delay the mixing of gas and air and create a more uniform oxygen concentration field for the combustion process. The maximum combustion temperature is reduced from 1973.65 K to 1935.88 K and the volume fraction of NOx in the flue gas is reduced from 188.08×10−6 to 143.47×10−6. However, compared with the nozzle axis distance, the length of the cylindrical section of the burner has little effect on the mixing of the flow field. Under different cylindrical section lengths, the maximum combustion temperature does not change more than 3 K, and the volume fraction of NOx in the flue gas changes within 5×10−6.

    AtıfScopus3OpenAlex2
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2021Scopus SJRQ2
    Effects of Optimized Operating Parameters on Combustion Characteristics and NOx Emissions of a Burner based on Orthogonal Analysis

    Xu, Qian; Akkurt, Nevzat; Yang, Gang; Zhu, Lidong; Shi, Kejian; Wang, Kang; Zou, Zhenwei; Liu, Zhihui; Wang, Jiulong; Du, Zhiwei

    To optimize the structure of the burner, improve the combustion performance, and reduce the emission of NOx, a self-circulating low NOx combustion technology was used to design a new type of flue gas self-circulating low NOx burner. Based on previous research on the numerical model of combustion and the composition of mixed gas on combustion and NOx emissions, the effect of various factors on the ejection coefficient of the flue gas self-circulating structure was analyzed using the orthogonal test method, and the burner operating parameters, such as preheating temperature and excess air coefficient, were deeply studied through the three-dimensional finite element numerical model in this paper. The results show that the diameter ratio of the nozzle and the length of the cylindrical section of the flue gas self-circulating structure have great influence on its ejection and mixing ability. The optimal ejection coefficient was 0.4829. Overall, the amount of NOx emissions greatly increased from 6.23×10−6 (volume fraction) at the preheating temperature 973 K to 3.5×10−3 at preheating temperature 1573 K. When the excess air coefficient decreased from 1.2 to 1, the maximum combustion temperature decreased from 2036.3 K to 1954.22 K, and the NOx emissions decreased from 352.29×10−6 to 159.73×10−6.

    AtıfScopus7OpenAlex8
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2021Scopus SJRQ1
    A new type of two-supply, one-return, triple pipe-structured heat loss model based on a low temperature district heating system

    Xu, Qian; Wang, Kang; Zou, Zhenwei; Zhong, Liqiong; Akkurt, Nevzat; Feng, Junxiao; Xiong, Yaxuan; Han, Jingxiao; Wang, Jiulong; Du, Yanping

    Based on the design concept of a fourth-generation smart pipe network system, this paper innovatively proposes a new TOTS (Two-supply/One-return, triple pipe structure) arrangement method for district heating systems. Moreover, to accurately predict the heat loss due to the pipeline operation of the multi-pipe system, based on the multipole calculation method, a new heat loss theoretical analytical model for the TOTS was created; additionally, a corresponding three-dimensional numerical simulation model was established, which was analyzed and numerically solved. The results showed that in comparison with thermal loss data measured by Danfoss et al., the above analytical and numerical models have a high accuracy, and the deviation is within 2%. Additionally, through calculations, it was found that the distance between the heating pipes is an important factor that affects the total heat loss from the new multi-control heating system and the actual heat exchange between pipes.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
    AtıfScopus74OpenAlex75
    ScopusWeb of Scienceİncele
  • MakaleYalnız künye2020Scopus SJRQ2
    Synthesis and Characterization of Disodium Hydrogen Phosphate Dodecahydrate-Lauric-Palmitic Acid Used for Indoor Energy Storage Floor Units

    Xu, Qian; Akkurt, Nevzat; Zou, Zhenwei; Liu, Yang; Feng, Junxiao; Yu, Chuqiao; Ding, Chong; Xiong, Yaxuan; Zhou, Jingzhi; Zang, Yong

    Organic and inorganic phase change materials (PCMs) are considered potential materials for thermal energy storage (TES) with different phase change characteristics. In this study, a novel organic-inorganic composite phase change material (PCM) called disodium hydrogen phosphate dodecahydrate-lauric-palmitic acid (D-LA-PACM) was prepared. Expanded graphite (EG) was selected as the support material, and the novel organic-inorganic form-stable PCM called D-LA-PAPCM/EG was prepared using the vacuum adsorption method. Differential scanning calorimetry, Fourier transform infrared spectroscopy, X-ray diffraction, leakage testing, melting and solidification cycle testing, thermal conductivity testing, scanning electron microscopy observation of the micromorphology, and other characterization methods were used to study the micro structure and morphology, thermal physical parameters, thermal conductivity, stability of the PCMs, and the comprehensive material properties of D-LA-PAPCM under the composite action of EG. Results indicated that the melting and freezing temperatures and latent heats of D-LA-PAPCM/EG were measured to be 31.6°C and 34.3°C and 142.9 and 142.8 J/g, respectively. Although some of the lauric-palmitic acid (LA-PA) and disodium hydrogen phosphate dodecahydrate (DHPD) separated in the multiple porous structures of EG after 1000 cycles, they could still absorb and release latent heats independently, with D-LA-PAPCM/EG still exhibiting good thermal stability. The thermal conductivity of D-LA-PAPCM/EG was 1.361 W/(mK). Therefore, the material and thermal properties of the prepared D-LA-PAPCM/EG indicate that it could be well used as a feasible material for energy-saving phase change floor units in indoor TES systems.

    • SDG 7 · Erişilebilir ve Temiz Enerji
    AtıfScopus18OpenAlex18
    ScopusWeb of Scienceİncele