Sürdürülebilir Kalkınma Amaçları

Yazarlar

  • MakaleAçık Erişim2026Scopus SJRQ2
    Local Scour Process in Conduit Aerated Water Jets

    Tuna, M. Cihat; Acar, Ramazan; Tunç, Mustafa

    High-velocity water jets emerging from hydraulic structures cause local scouring in downstream areas, creating significant risks to structural safety. In this study, the effects of natural aeration provided through pressurized pipes on jet-induced scouring were investigated through laboratory experiments. A total of 60 experiments were conducted for different gate openings, flow rates, and downstream water levels; the scour geometries created by aerated and non-aerated jets were compared. The aeration level was defined by the dimensionless air-to-water flow ratio (Qa/Qw); maximum scour depth, scour length, scour slope angle, and jet fall distance were considered as basic evaluation parameters. The experimental results showed that increased aeration significantly reduced the maximum scour depth and scour length while moving the point of contact of the jet further upstream. While the scour depth and slope angles reached their highest values in non-aerated jets, shallower and flatter scour profiles were formed in aerated conditions. An empirical relationship predicting the maximum scour depth using experimental data has been developed and found to be in high correlation with the measured values (R2 = 0.93). The findings reveal that channel aeration is an effective method for reducing scouring and demonstrate that this approach can be considered a safe and economical alternative in the design of spillways, wastewater treatment plants, and similar hydraulic systems.

  • MakaleAçık Erişim2026Scopus SJRQ1
    The effect of hydrostatic water level on the local scour downstream of plunging aerated jets

    Tunc, Mustafa; Aytac, Ayca; Tuna, M. Cihat; Acar, Ramazan

    This paper reports an experimental study on the effect of hydrostatic water level on local scour downstream of plunge aerated jets. To examine the shape of the scour for non-cohesive bed material, different flow and air rates, and different aeration capabilities, hydrostatic water level circumstances were tested. The water jets were aerated using conduit systems with varying cover opening ratios. Measurements were made to determine the length of the scour hole, the value of the maximum scour depth, the location of the maximum scour depth, and the scour hole profile in equilibrium. The current findings show that downstream hydrostatic water levels have a significant impact on the maximum depth and area of scour. Additionally, it was discovered that the conduit gate opening ratio and aeration performance (Qa/Qw) are crucial factors that affect the geometry and diameters of scour holes. The properties of scour caused by various hydrostatic levels were systematically compared to develop empirical correlations for predicting the maximum scour depth. Consequently, predictive emprical formulas incorporating these hydrostatic variations and aeration parameters are presented to improve engineering design accuracy.

    • SDG 6 · Temiz Su ve Sanitasyon