Sürdürülebilir Kalkınma Amaçları
Yazarlar
Yayınlar
- MakaleYalnız künye2026Scopus SJRQ2An Innovative Thermal Management Approach Enhanced by Thermoelectric Stations and Turbulators for Lithium-Ion Batteries
Tuğan, Volkan; Yardımcı, Uğurcan
The design of an effective battery thermal management system is critical to ensure the safe, efficient, and long-lasting operation of lithium-ion batteries. Excessive heat generation and temperature non-uniformity among cells in high energy density battery systems lead to performance degradation, accelerated aging, and an increased risk of thermal runaway. Although liquid-cooled systems and thermoelectric module-assisted solutions have been extensively investigated separately in the literature, studies that holistically evaluate multiple thermoelectric stations combined with an innovative flow channel design and turbulator integration remain limited. This gap constitutes a significant research need, particularly in terms of improving temperature uniformity and reducing maximum cell temperature. In this study, to address this research gap, a novel liquid-cooled battery thermal management system integrating thermoelectric coolers and turbulators within the flow channel is proposed. The thermal performance of the proposed system was systematically analyzed using computational fluid dynamics under three different configurations (conventional system, thermoelectric-assisted system, and turbulator-integrated thermoelectric-assisted system) and four different mass flow rates (0.0008, 0.0013, 0.0018, and 0.0023 kg/s). The results indicate that, at a mass flow rate of 0.0023 kg/s, the integration of thermoelectric coolers and turbulators reduces the maximum battery temperature by 8.95 K and the maximum temperature difference by 6.83 K. At the highest mass flow rate, the proposed system achieves a maximum battery temperature of 306 K and a maximum temperature difference of 4.5 K, ensuring both effective cooling performance and high temperature uniformity. Overall, the results in terms of cooling performance and temperature uniformity demonstrate that the combination of thermoelectric modules and turbulators offers significant potential for advanced battery thermal management system applications and offers an effective solution for high-energy-density systems.
- MakaleAçık Erişim2009Scopus SJRQ1Heat transfer augmentation by swirl generators inserted into a tube with constant heat flux
Kurtbas, Irfan; Guelcimen, Fevzi; Akbulut, Abdullah; Buran, Dincer
A novel conical injector type swirl generator (CITSG) is devised in this study. Performances of heat transfer and pressure drop in a pipe with the CITSG are experimentally examined for the CITSGs' angle (alpha) of 30 degrees, 45 degrees and 60 degrees in Reynolds number (Re) range of 10,000-35,000. Moreover, circular holes with different numbers (N) and cross-section areas (A(h)) are drilled on the CITSG. In this way, total areas (A(t) = N . A(h)) of the holes on the CITSG are equaled each other. Besides, flow directors having three different angles (beta = 30 degrees, 60 degrees and 90 degrees) to radial direction are attached to every one of the holes. This study is a typical example for decaying flow. All experiments were conduced with air accordingly; Prandtl number was approximately fixed at 0.71. The local Nusselt number (Nu(x)), heat transfer enhancement ratio (Nu(ER)) and heat transfer performance ratio (Nu(PR)) are calculated and discussed in this paper. It is found that the Nu(ER) decreases with increase in Reynolds number, the director angle (beta), the director diameter (d), and with decrease in the CITSG angle (alpha). Likewise, variation of Nu(PR) and Nu(ER) is also essentially similar for the same independent parameters. (C) 2009 Elsevier Ltd. All rights reserved.
AtıfWoS32OpenAlex31İncele