Sürdürülebilir Kalkınma Amaçları

Bu dergideki yayınlar

3 →
  • MakaleYalnız künye2024Scopus SJRQ2
    Synthesis and characterization of TiNbZrMo medium-entropy bio-composites: Microstructure, mechanical properties, and in vitro degradation

    Say, Yakup

    This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1–15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5–5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus2WoS1OpenAlex3
    ScopusWeb of SciencePubMedİncele
  • MakaleAçık Erişim2023Scopus SJRQ2
    Fabrication of hydroxyapatite-based nano-gold and nano-silver-doped bioceramic bone grafts: Enhanced mechanostructure, cell viability, and nuclear abnormality properties

    Demirel, M.; Aslan, N.; Aksakal, B.; Arslan, M.E.

    In this study, nano-gold (nAu) and nano-silver (nAg) were doped at the molar ratios of Molar5–Molar30 to the Hydroxyapatite (HAp)-based bioceramic bone graft synthesized by the sol–gel method. The effects of nAu and nAg on structural, mechanical, cell viability, and nuclear abnormality of the synthesized bioceramic grafts were evaluated. The chemical and morphological properties of the bone grafts after production were examined through XRD and SEM–EDX analyses and mechanical tests. To determine the biocompatibility of the bone grafts, cell viability tests were performed using human fibroblast cells. In the cytotoxicity analyses, only HAp and HAp-nAu5 grafts did not show toxicological properties at any concentration, while HAp-nAg5 among the nAg-containing grafts gave the best results at the 200–100 μg/mL concentrations and showed significant cytotoxicity in human fibroblast cells. The other nAu-containing grafts showed toxicological properties in the concentration range of 200–50 μg/mL and nAg-containing grafts in the concentration range of 200–100 μg/mL against the negative control. The micronucleus (MN) analyses showed that the lowest total MN and L (lobbed) amounts, while the lowest total N (notched) amount, was obtained from the only HAp graft. It was found that the nAg-doped bone grafts gave higher total MN, L, and N amounts compared to the nAu-doped bone grafts. Furthermore, while the mean nuclear abnormality (NA) values of all grafts gave close results, the highest values were again obtained from the nAg-doped bone grafts.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus7WoS6OpenAlex9
    ScopusWeb of SciencePubMedİncele
  • MakaleYalnız künye2022Scopus SJRQ2
    Structural, biocompatibility, and antibacterial properties of Ge–DLC nanocomposite for biomedical applications

    Arslan, Mehmet Enes; Kurt, Mustafa Şükrü; Aslan, Naim; Kadi, Abdurrahim; Öner, Sena; Çobanoğlu, Şeymanur; Yazici, Ayşenur

    Integrative production of new nanocomposites has been used to enhance favorable features of biomaterials for unlocking ultimate potential of different molecules. In the present study, advantageous properties of diamond like carbons (DLC) and germanium (Ge) like greater biocompatibility and antibacterial attributes were aimed to combined into a thin film. For this purpose, 400 nm DLC–Ge nanocomposite was coated on the borosilicate glasses via the magnetron sputtering and surface characteristics was analyzed by scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and The Raman spectrum. Biocompatibility analysis were performed by 3-(4,5-Dimethylthiazol-2-yl) (MTT) cell viability assay and Hoechst 33258 fluorescent staining genotoxicity assessments on the human fibroblast cell line (HDFa). Finally, antibacterial properties of DLC–Ge nanocomposite coatings were investigated by Pseudomonas aeruginosa (ATCC 27853) and Staphylococcus aureus (ATCC 25923) bacterial attachment analysis. As a result of magnetron sputtering coating, nearly 400 nm thick DLC–Ge nanocomposite film showed a smooth, a non-porous, and a dense characteristic. Cell viability analysis showed that Ge–DLC coatings permits %95 cell surface growth of fibroblast cells. Also, there were no significant difference in aspect of nuclear abnormalities compared to the (−) control which showed nonmutagenic features of the thin film. Finally, antibacterial attachment analysis put forth that Ge–DLC coatings inhibits bacterial adhesion as %40 and %25 rates for P. aeruginosa and S. aureus bacterial strains, respectively. From these results, DLC–Ge nanocomposites could be proposed as a potential new biomaterial for various biomedical applications.

    • SDG 3 · Sağlık ve Kaliteli Yaşam
    AtıfScopus20WoS16OpenAlex19
    ScopusWeb of SciencePubMedİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn1552-4973
dc.date.accessioned2026-10-28T14:54:30.634644789Z
dc.date.available2026-10-28T14:54:30.634644789Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1717
dc.publisherJohn Wiley and Sons Inc
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleJournal of Biomedical Materials Research - Part B Applied Biomaterials