Synthesis and characterization of TiNbZrMo medium-entropy bio-composites: Microstructure, mechanical properties, and in vitro degradation

MakaleYalnız künyeScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

This study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1–15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5–5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2304Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/jbm.b.35415Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
WoS
1
OpenAlex
3
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorSay, Yakup
dc.date.accessioned2026-10-28T14:55:12.821469089Z
dc.date.available2026-10-28T14:55:12.821469089Z
dc.date.issued2024
dc.description.abstractThis study reports the synthesis and characterization of hydroxyapatite (HA)-based bio-composites reinforced with varying amounts (by weight, 1–15 wt.%) of bio-medium entropy alloy (BioMEA) for load-bearing implant applications. BioMEA powders consisting of Ti, Nb, Zr, and Mo were mechanically alloyed for 100 h and subsequently added to HA using powder metallurgy techniques. To show the effect of BioMEA, the microstructure, density, and mechanical tests have been conducted and the synthesized BioMEA was characterized by scanning electron microscope (SEM), x-ray diffractometer (XRD), and Fourier-transform infrared spectroscopy (FTIR) analysis. In addition, in vitro degradation behavior and bioactivity analyses of bio-composites have been conducted. XRD analysis revealed the formation of BioMEA after 20 h of mechanical alloying. The highest density value of 2.47 g/cm3 was found in 15 wt.% BioMEA-reinforced bio-composite. The addition of BioMEA reinforcement led to a significant increase in hardness and tensile strength values, with the highest values observed at 15 wt.% reinforcement. Compression tests demonstrated a significant increase in compressive strength and deformation capability of the bio-composites with the highest values observed at 15 wt.% BioMEA addition. The highest toughness of 7.68 kJ/m2 was measured in 10 wt.% MEA-reinforced bio-composites. The produced bio-composite materials have an elastic modulus between 3.5–5.5 GPa, which may provide a solution to the stress shielding problems caused by the high elastic modulus of metallic implant materials. The most severe degradation occurred in 15 wt.% MEA-reinforced bio-composites, and the effect of degradation caused a decrease in Ca and an increase in Ti-Ni-Zr-Mo in all bio-composites. These findings suggest that HA/BioMEA bio-composites have the potential to be developed as advanced biomaterials with moderate mechanical and biological properties for load-bearing implant applications.
dc.identifier.articlenumbere35415
dc.identifier.doi10.1002/jbm.b.35415
dc.identifier.eissn1552-4981
dc.identifier.issn1552-4973
dc.identifier.issue6
dc.identifier.pmid38773744
dc.identifier.scopus2-s2.0-85193856475
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2304
dc.identifier.volume112
dc.identifier.wosWOS:001228315900001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofJournal of Biomedical Materials Research - Part B Applied Biomaterials
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectbio-composite
dc.subjecthydroxyapatite
dc.subjectmedium entropy alloys
dc.subjectTiNbZrMo
dc.subject.classificationEngineering, Biomedical
dc.subject.classificationMaterials Science, Biomaterials
dc.subject.classificationEngineering
dc.subject.classificationMaterials Science
dc.subject.otherAlloys
dc.subject.otherBiocompatible Materials
dc.subject.otherDurapatite
dc.subject.otherEntropy
dc.subject.otherMaterials Testing
dc.subject.otherNiobium
dc.subject.otherTitanium
dc.subject.otherZirconium
dc.subject.otherBearings (machine parts)
dc.subject.otherBiodegradation
dc.subject.otherCompression testing
dc.subject.otherCompressive strength
dc.subject.otherElastic moduli
dc.subject.otherFourier transform infrared spectroscopy
dc.subject.otherHigh-entropy alloys
dc.subject.otherHydroxyapatite
dc.subject.otherMechanical alloying
dc.subject.otherMicrostructure
dc.subject.otherMolybdenum alloys
dc.subject.otherNiobium alloys
dc.subject.otherScanning electron microscopy
dc.subject.otherTensile strength
dc.subject.otherTitanium alloys
dc.subject.otherX ray diffraction
dc.subject.otherZircaloy
dc.subject.othermolybdenum
dc.subject.othernickel
dc.subject.otheralloy
dc.subject.otherbiomaterial
dc.subject.otherBio-media
dc.subject.otherBiocomposite
dc.subject.otherIn-vitro
dc.subject.otherLoad-bearing
dc.subject.otherMechanical
dc.subject.otherMedium entropy
dc.subject.otherMedium entropy alloy
dc.subject.otherSynthesis and characterizations
dc.subject.otherTinbzrmo
dc.subject.otherX ray diffractometers
dc.subject.otherArticle
dc.subject.otherdegradation
dc.subject.otherenergy dispersive X ray spectroscopy
dc.subject.otherhardness
dc.subject.otherin vitro study
dc.subject.othermechanical test
dc.subject.othermetallurgy
dc.subject.otherparticle size
dc.subject.othersurface property
dc.subject.otherVickers hardness
dc.subject.otherYoung modulus
dc.subject.otherchemistry
dc.subject.otherReinforcement
dc.titleSynthesis and characterization of TiNbZrMo medium-entropy bio-composites: Microstructure, mechanical properties, and in vitro degradation
dc.typeArticle
rdl.citation.openalex3
rdl.citation.scopus2
rdl.citation.wos1
rdl.departmentDepartment of Machine and Metallic Technology, Munzur University, Tunceli, Turkey
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)