A Selective and Sensitive Electrochemical Sensor for Pyridoxine Hydrochloride (Vitamin B6) in Pharmaceutic Tablet

MakaleYalnız künyeScopus SJRQ3

Özet

In this study, a copper (II) oxide-glutardialdehyde modified boron doped diamond electrode was used as a sensor for the electroanalysis of pyridoxine hydrochloride (vitamin B6) for the first time. A copper oxide-glutardialdehyde modified boron doped diamond electrode (CuO-GA2/BDDE) was prepared by a simple drop casting method on boron diamond electrode (BDDE) by suspending CuO with glutardialdehyde (CuO-GA2). The electrochemical behavior of vitamin B6 was examined using cyclic voltammetry (CV) and its electrochemical determination was found by differential pulse voltammetry (DPV). Under optimum experimental conditions, the linear working range of vitamin B6 on CuO-GA2/BDDE via the DPV method was calculated as 5.96×10−6–3.75×10−4 mol.L−1. The limit of detection (LOD) was calculated as 1.99×10−7 mol.L−1. In order to demonstrate the selectivity of the method improved for the quantitative determination of vitamin B6 on the CuO-GA2/BDDE, the interference effect of some cations (Zn2+, Cu2+, Pb2+) and anions (NO3−, Cl−) was investigated via the DPV method. The improved electrode was successfully used for the electroanalysis of vitamin B6 in a tablet sample of the commercial Tribeksol® (deva) (250/250/1 mg B1+B6+B12).

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2008Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/slct.202303112Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorKoçak, Berna
dc.date.accessioned2026-10-28T14:54:49.512923083Z
dc.date.available2026-10-28T14:54:49.512923083Z
dc.date.issued2023
dc.description.abstractIn this study, a copper (II) oxide-glutardialdehyde modified boron doped diamond electrode was used as a sensor for the electroanalysis of pyridoxine hydrochloride (vitamin B6) for the first time. A copper oxide-glutardialdehyde modified boron doped diamond electrode (CuO-GA2/BDDE) was prepared by a simple drop casting method on boron diamond electrode (BDDE) by suspending CuO with glutardialdehyde (CuO-GA2). The electrochemical behavior of vitamin B6 was examined using cyclic voltammetry (CV) and its electrochemical determination was found by differential pulse voltammetry (DPV). Under optimum experimental conditions, the linear working range of vitamin B6 on CuO-GA2/BDDE via the DPV method was calculated as 5.96×10−6–3.75×10−4 mol.L−1. The limit of detection (LOD) was calculated as 1.99×10−7 mol.L−1. In order to demonstrate the selectivity of the method improved for the quantitative determination of vitamin B6 on the CuO-GA2/BDDE, the interference effect of some cations (Zn2+, Cu2+, Pb2+) and anions (NO3−, Cl−) was investigated via the DPV method. The improved electrode was successfully used for the electroanalysis of vitamin B6 in a tablet sample of the commercial Tribeksol® (deva) (250/250/1 mg B1+B6+B12).
dc.identifier.articlenumbere202303112
dc.identifier.doi10.1002/slct.202303112
dc.identifier.issn2365-6549
dc.identifier.issue39
dc.identifier.scopus2-s2.0-85174466856
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2008
dc.identifier.volume8
dc.identifier.wosWOS:001084157800001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofChemistrySelect
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBoron Doped Diamond Electrode
dc.subjectCopper (II) Oxide, Glutardialdehyde
dc.subjectDifferential Puls Voltammetry
dc.subjectElectroanalysis
dc.subjectVitamin B6
dc.subject.classificationChemistry, Multidisciplinary
dc.subject.classificationChemistry
dc.subject.otherGLASSY-CARBON ELECTRODE
dc.subject.otherVOLTAMMETRIC DETERMINATION
dc.subject.otherNONENZYMATIC GLUCOSE
dc.subject.otherCUO NANOPARTICLES
dc.subject.otherBETA-CYCLODEXTRIN
dc.subject.otherOXIDE
dc.subject.otherSAMPLES
dc.subject.otherBEHAVIOR
dc.subject.otherPLATFORM
dc.titleA Selective and Sensitive Electrochemical Sensor for Pyridoxine Hydrochloride (Vitamin B6) in Pharmaceutic Tablet
dc.typeArticle
rdl.citation.openalex6
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)