Automated Hypertension Detection Using ConvMixer and Spectrogram Techniques with Ballistocardiograph Signals

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Blood pressure is the pressure exerted by the blood in the veins against the walls of the veins. If this value is above normal levels, it is known as high blood pressure (HBP) or hypertension (HPT). This health problem which often referred to as the “silent killer” reduces the quality of life and causes severe damage to many body parts in various ways. Besides, its mortality rate is very high. Hence, rapid and effective diagnosis of this health problem is crucial. In this study, an automatic diagnosis of HPT has been proposed using ballistocardiography (BCG) signals. The BCG signals were transformed to the time-frequency domain using the spectrogram method. While creating the spectrogram images, parameters such as window type, window length, overlapping rate, and fast Fourier transform size were adjusted. Then, these images were classified using ConvMixer architecture, similar to vision transformers (ViT) and multi-layer perceptron (MLP)-mixer structures, which have attracted a lot of attention. Its performance was compared with classical architectures such as ResNet18 and ResNet50. The results obtained showed that the ConvMixer structure gave very successful results and a very short operation time. Our proposed model has obtained an accuracy of 98.14%, 98.79%, and 97.69% for the ResNet18, ResNet50, and ConvMixer architectures, respectively. In addition, it has been observed that the processing time of the ConvMixer architecture is relatively short compared to these two architectures.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2818Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.3390/diagnostics13020182Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
21
WoS
16
OpenAlex
21
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzcelik, Salih T. A.
dc.contributor.authorUyanık, Hakan
dc.contributor.authorDeniz, Erkan
dc.contributor.authorSengur, Abdulkadir
dc.date.accessioned2026-10-28T14:55:50.793800737Z
dc.date.available2026-10-28T14:55:50.793800737Z
dc.date.issued2023
dc.description.abstractBlood pressure is the pressure exerted by the blood in the veins against the walls of the veins. If this value is above normal levels, it is known as high blood pressure (HBP) or hypertension (HPT). This health problem which often referred to as the “silent killer” reduces the quality of life and causes severe damage to many body parts in various ways. Besides, its mortality rate is very high. Hence, rapid and effective diagnosis of this health problem is crucial. In this study, an automatic diagnosis of HPT has been proposed using ballistocardiography (BCG) signals. The BCG signals were transformed to the time-frequency domain using the spectrogram method. While creating the spectrogram images, parameters such as window type, window length, overlapping rate, and fast Fourier transform size were adjusted. Then, these images were classified using ConvMixer architecture, similar to vision transformers (ViT) and multi-layer perceptron (MLP)-mixer structures, which have attracted a lot of attention. Its performance was compared with classical architectures such as ResNet18 and ResNet50. The results obtained showed that the ConvMixer structure gave very successful results and a very short operation time. Our proposed model has obtained an accuracy of 98.14%, 98.79%, and 97.69% for the ResNet18, ResNet50, and ConvMixer architectures, respectively. In addition, it has been observed that the processing time of the ConvMixer architecture is relatively short compared to these two architectures.
dc.identifier.articlenumber182
dc.identifier.doi10.3390/diagnostics13020182
dc.identifier.eissn2075-4418
dc.identifier.issn2075-4418
dc.identifier.issue2
dc.identifier.pmcidPMC9858153
dc.identifier.pmid36672992
dc.identifier.scopus2-s2.0-85146816751
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2818
dc.identifier.volume13
dc.identifier.wosWOS:000915004800001
dc.language.isoen
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)
dc.relation.ispartofDiagnostics
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectBCG signal
dc.subjectconvolutional mixer
dc.subjecthigh blood pressure
dc.subjecthypertension
dc.subjectspectrogram
dc.subject.classificationMedicine, General & Internal
dc.subject.classificationGeneral & Internal Medicine
dc.subject.otheradult
dc.subject.otherArticle
dc.subject.otherballistocardiography
dc.subject.othercomparative study
dc.subject.othercomputer assisted diagnosis
dc.subject.othercontrolled study
dc.subject.otherfemale
dc.subject.otherFourier transform
dc.subject.otherhuman
dc.subject.otherhypertension
dc.subject.othermajor clinical study
dc.subject.othermale
dc.subject.othermiddle aged
dc.subject.othermortality rate
dc.subject.othermultilayer perceptron
dc.subject.otheroperation duration
dc.subject.otherresidual neural network
dc.subject.othersignal detection
dc.titleAutomated Hypertension Detection Using ConvMixer and Spectrogram Techniques with Ballistocardiograph Signals
dc.typeArticle
rdl.citation.openalex21
rdl.citation.scopus21
rdl.citation.wos16
rdl.departmentElectrical-Electronics Engineering Department, Engineering Faculty, Bingol University, Bingol 12000, Turkey
rdl.departmentElectrical-Electronics Engineering Department, Engineering Faculty, Munzur University, Tunceli 62000, Turkey
rdl.departmentElectrical-Electronics Engineering Department, Technology Faculty, Firat University, Elazig 23119, Turkey
rdl.oa.statusgold
rdl.oa.statusgreen
rdl.oa.urlhttps://www.mdpi.com/2075-4418/13/2/182/pdf?version=1672910235
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)