Investigation of Microstructural and Mechanical Properties of Different Titanium Alloys for Gamma Radiation Properties and Implant Applications

MakaleYalnız künyeScopus SJRQ2

Özet

In this study, the advantages and disadvantages of different titanium alloys used as industrial and biomedical implant materials are evaluated within the scope of multiple parameters. This research is supported by simulations and aims to understand how titanium and titanium alloys differ mechanically, micro-structurally and in terms of radioactivity. The matrix material of the eight samples used in this research is titanium. The effects of different elements such as Al, V, Sn, Ni, Pb, Mo, Cr, Zr, Fe, Nb, Co on titanium have been examined, the results are compared by considering multiple parameters, and the superior properties of the prominent alloys are highlighted. As a result of the mechanical and electrical tests performed on the alloys, it is obvious that the titanium alloy consisting of Mo and Nb has the highest Brinell hardness, elastic modulus, tensile strength and electrical conductivity parameters compared to other alloys examined within the scope of this research. In the metallographic studies and analyses on samples made up of different alloys, different structures and images emerge for each alloy. These elements rapidly lower the solidification temperature of the material, allowing the β phase to be formed. It has been observed that the two-phase situation has positive effects on the material. On the other hand, the results of gamma ray attenuation tests reveal that Mo and Nb, which make up the alloy, have superior performance compared to other alloy samples due to their high atomic number. Graphical abstract: [Figure not available: see fulltext.]

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/2879Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s11665-021-05830-0Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
8
WoS
7
OpenAlex
11
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTaşgın, Yahya
dc.date.accessioned2026-10-28T14:55:55.600955258Z
dc.date.available2026-10-28T14:55:55.600955258Z
dc.date.issued2021
dc.description.abstractIn this study, the advantages and disadvantages of different titanium alloys used as industrial and biomedical implant materials are evaluated within the scope of multiple parameters. This research is supported by simulations and aims to understand how titanium and titanium alloys differ mechanically, micro-structurally and in terms of radioactivity. The matrix material of the eight samples used in this research is titanium. The effects of different elements such as Al, V, Sn, Ni, Pb, Mo, Cr, Zr, Fe, Nb, Co on titanium have been examined, the results are compared by considering multiple parameters, and the superior properties of the prominent alloys are highlighted. As a result of the mechanical and electrical tests performed on the alloys, it is obvious that the titanium alloy consisting of Mo and Nb has the highest Brinell hardness, elastic modulus, tensile strength and electrical conductivity parameters compared to other alloys examined within the scope of this research. In the metallographic studies and analyses on samples made up of different alloys, different structures and images emerge for each alloy. These elements rapidly lower the solidification temperature of the material, allowing the β phase to be formed. It has been observed that the two-phase situation has positive effects on the material. On the other hand, the results of gamma ray attenuation tests reveal that Mo and Nb, which make up the alloy, have superior performance compared to other alloy samples due to their high atomic number. Graphical abstract: [Figure not available: see fulltext.]
dc.identifier.doi10.1007/s11665-021-05830-0
dc.identifier.eissn1544-1024
dc.identifier.endpage6223
dc.identifier.issn1059-9495
dc.identifier.issue8
dc.identifier.scopus2-s2.0-85105430013
dc.identifier.startpage6203
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/2879
dc.identifier.volume30
dc.identifier.wosWOS:000648019200002
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofJournal of Materials Engineering and Performance
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectmicrostructures
dc.subjectradiation shielding
dc.subjecttitanium alloy
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationMaterials Science
dc.subject.otherAtoms
dc.subject.otherElectromagnetic wave attenuation
dc.subject.otherGamma rays
dc.subject.otherTensile strength
dc.subject.otherTitanium alloys
dc.subject.otherBiomedical implants
dc.subject.otherDifferent structure
dc.subject.otherElectrical conductivity
dc.subject.otherGamma-ray attenuation
dc.subject.otherMechanical and electrical tests
dc.subject.otherMultiple parameters
dc.subject.otherRadiation properties
dc.subject.otherSolidification temperature
dc.subject.otherMetal implants
dc.titleInvestigation of Microstructural and Mechanical Properties of Different Titanium Alloys for Gamma Radiation Properties and Implant Applications
dc.typeArticle
rdl.citation.openalex11
rdl.citation.scopus8
rdl.citation.wos7
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)