Graphene reinforced hybrid-bioceramic coatings on porous-Ti6Al4V for biomedical applications: morphology, corrosion resistance, and cell viability

MakaleAçık ErişimScopus SJRQ1
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

The effect of Hydroxyapatite (HA)-based coatings reinforced with reduced graphene oxide (rGO) on porous-Ti6Al4V (P-Ti6Al4V) alloys in terms of electrochemical corrosion and cell viability for potential biomedical applications was investigated in this study. The scaffold-porous surfaces of P-Ti6Al4V were coated by the biocomposite structure of HA and reduced graphene oxide (rGO) at various porosity rates (40, 50, and 60%) by using the sol–gel dip-coating method. The results of 0.5, 1.0, and 1.5 wt% rGO-HA coatings were compared to coatings that contained only HA (free-rGO). Raman spectroscopy, X-ray diffractometer, and scanning electron microscopy were used for structural and morphological characterizations. The coatings in vitro corrosion susceptibilities were tested in simulated body fluid at 37 °C. Compared to free-rGO coatings, the results showed that rGO reinforcements phases reduced the corrosion rate of the scaffolds. The corrosion rate increased as the porosity content of the scaffolds increased. In vitro cell viability tests revealed that samples of 0.5 and 1.0 wt% rGO-HA coating groups performed better than the control and 1.5 wt% rGO-HA samples. Graphical abstract: [Figure not available: see fulltext.]

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3073Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1007/s10853-022-07695-7Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
8
WoS
7
OpenAlex
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAslan, N.
dc.contributor.authorAksakal, B.
dc.contributor.authorDikici, B.
dc.contributor.authorSinirlioglu, Z.A.
dc.date.accessioned2026-10-28T14:56:11.062118070Z
dc.date.available2026-10-28T14:56:11.062118070Z
dc.date.issued2022
dc.description.abstractThe effect of Hydroxyapatite (HA)-based coatings reinforced with reduced graphene oxide (rGO) on porous-Ti6Al4V (P-Ti6Al4V) alloys in terms of electrochemical corrosion and cell viability for potential biomedical applications was investigated in this study. The scaffold-porous surfaces of P-Ti6Al4V were coated by the biocomposite structure of HA and reduced graphene oxide (rGO) at various porosity rates (40, 50, and 60%) by using the sol–gel dip-coating method. The results of 0.5, 1.0, and 1.5 wt% rGO-HA coatings were compared to coatings that contained only HA (free-rGO). Raman spectroscopy, X-ray diffractometer, and scanning electron microscopy were used for structural and morphological characterizations. The coatings in vitro corrosion susceptibilities were tested in simulated body fluid at 37 °C. Compared to free-rGO coatings, the results showed that rGO reinforcements phases reduced the corrosion rate of the scaffolds. The corrosion rate increased as the porosity content of the scaffolds increased. In vitro cell viability tests revealed that samples of 0.5 and 1.0 wt% rGO-HA coating groups performed better than the control and 1.5 wt% rGO-HA samples. Graphical abstract: [Figure not available: see fulltext.]
dc.description.sponsorshipYildiz Teknik Üniversitesi, (2015-07-02-KAP03, FCD-2019-3511)
dc.description.sponsorshipYildiz Teknik Üniversitesi
dc.identifier.doi10.1007/s10853-022-07695-7
dc.identifier.eissn1573-4803
dc.identifier.endpage16874
dc.identifier.issn0022-2461
dc.identifier.issue35
dc.identifier.scopus2-s2.0-85137534734
dc.identifier.startpage16858
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3073
dc.identifier.volume57
dc.identifier.wosWOS:000850383800002
dc.language.isoen
dc.publisherSpringer
dc.relation.ispartofJournal of Materials Science
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationMaterials Science
dc.subject.otherBody fluids
dc.subject.otherCorrosion rate
dc.subject.otherCorrosion resistance
dc.subject.otherCorrosion resistant coatings
dc.subject.otherElectrochemical corrosion
dc.subject.otherGraphene
dc.subject.otherMedical applications
dc.subject.otherMorphology
dc.subject.otherPorosity
dc.subject.otherReinforcement
dc.subject.otherScanning electron microscopy
dc.subject.otherSols
dc.subject.otherBioceramic coatings
dc.subject.otherBiocomposite
dc.subject.otherBiomedical applications
dc.subject.otherCell viability
dc.subject.otherCorrosion cells
dc.subject.otherHydroxyapatite coating
dc.subject.otherPorous surface
dc.subject.otherReduced graphene oxides
dc.subject.otherTi-6al-4v
dc.subject.otherTi-6Al-4V alloy
dc.subject.otherHydroxyapatite
dc.titleGraphene reinforced hybrid-bioceramic coatings on porous-Ti6Al4V for biomedical applications: morphology, corrosion resistance, and cell viability
dc.typeArticle
rdl.citation.openalex6
rdl.citation.scopus8
rdl.citation.wos7
rdl.oa.statusgreen
rdl.oa.urlhttps://doi.org/10.2139/ssrn.4028228
rdl.scopus.quartileQ1
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)