Effects of temperature and impactor nose diameter on the impact behavior of PA6 and PP thermoplastic composites

MakaleYalnız künyeScopus SJRQ3

Özet

In this study, the effects of temperature and impactor nose diameter on the impact behavior of woven glass-reinforced polyamide 6 (PA6) and polypropylene (PP) thermoplastic composites were investigated experimentally. Impact energies are chosen as 10, 30, 50, 70, 90, 110, 130, and 170 J. The thickness of composite materials is 4 mm. Impact tests were performed using a drop weight impact testing machine, CEAST-Fractovis Plus, and the load capacity of test machine is 22 kN. Hemispherical impactor nose diameter of 12, 7, and 20 mm were used as an impactor. The tests are conducted at room temperature (20°C and 75°C). As a result, the PP composites of the same thickness absorbed more energy than PA6 composites. The amount of absorbed energy of PP and PA6 composites decreased with temperature.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3244Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1177/0095244318780509Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
7
WoS
6
OpenAlex
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorDogan, Akar
dc.contributor.authorArman, Yusuf
dc.date.accessioned2026-10-28T14:56:22.992036634Z
dc.date.available2026-10-28T14:56:22.992036634Z
dc.date.issued2019
dc.description.abstractIn this study, the effects of temperature and impactor nose diameter on the impact behavior of woven glass-reinforced polyamide 6 (PA6) and polypropylene (PP) thermoplastic composites were investigated experimentally. Impact energies are chosen as 10, 30, 50, 70, 90, 110, 130, and 170 J. The thickness of composite materials is 4 mm. Impact tests were performed using a drop weight impact testing machine, CEAST-Fractovis Plus, and the load capacity of test machine is 22 kN. Hemispherical impactor nose diameter of 12, 7, and 20 mm were used as an impactor. The tests are conducted at room temperature (20°C and 75°C). As a result, the PP composites of the same thickness absorbed more energy than PA6 composites. The amount of absorbed energy of PP and PA6 composites decreased with temperature.
dc.identifier.doi10.1177/0095244318780509
dc.identifier.eissn1530-8006
dc.identifier.endpage74
dc.identifier.issn0095-2443
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85048124188
dc.identifier.startpage64
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3244
dc.identifier.volume51
dc.identifier.wosWOS:000457635600005
dc.language.isoen
dc.publisherSAGE Publications Ltd
dc.relation.ispartofJournal of Elastomers and Plastics
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectE-glass
dc.subjecteffects of impactor diameter
dc.subjectImpact behavior
dc.subjecttemperature effect
dc.subjectthermoplastic composite
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationPolymer Science
dc.subject.classificationMaterials Science
dc.subject.otherGlass
dc.subject.otherImpact testing
dc.subject.otherLoad testing
dc.subject.otherPolypropylenes
dc.subject.otherReinforced plastics
dc.subject.otherThermal effects
dc.subject.otherAbsorbed energy
dc.subject.otherDrop-weight impact testing
dc.subject.otherE-glass
dc.subject.otherEffects of temperature
dc.subject.otherImpact behavior
dc.subject.otherImpact energy
dc.subject.otherImpactors
dc.subject.otherThermoplastic composite
dc.subject.otherTemperature
dc.titleEffects of temperature and impactor nose diameter on the impact behavior of PA6 and PP thermoplastic composites
dc.typeArticle
rdl.citation.openalex6
rdl.citation.scopus7
rdl.citation.wos6
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)