COD removal from leachate by electrocoagulation process: Treatment with monopolar electrodes in parallel connection
Özet
This study examines the removal of chemical oxygen demand (COD) from landfill leachate generated from the municipal landfill site of Bingol, Turkey. The effect of parameters such as current density, pH, and inter-electrode distance during the electrocoagulation (EC) process on COD removal of the process was investigated. Moreover, for COD removal, the energy consumption and operating costs were calculated for iron electrode under the EC conditions. COD removal efficiency was 72.13% at the current density of 16 mA m-2, pH of 8.05, and the inter-electrode distance of 9 mm at the detention time of 60 min with iron electrode and the COD concentration was reduced from 6,100 mg L-1 to 1,700 mg L-1 by EC. The highest value of the electrical energy and electrode consumptions per kg of COD in the optimum conditions were determined as 0.055 kWh kg-1 COD and 3.43 kg kg-1 COD and the highest operating cost value was found to be 1.41 US$ kg-1 COD for 0-60 min time intervals.
Anahtar Kelimeler
- Scopus
- 29
- WoS
- 29
- OpenAlex
- 32
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Tanyol, Mehtap | |
| dc.contributor.author | Ogedey, Aysenur | |
| dc.contributor.author | Oguz, Ensar | |
| dc.date.accessioned | 2026-10-28T14:56:57.318545868Z | |
| dc.date.available | 2026-10-28T14:56:57.318545868Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | This study examines the removal of chemical oxygen demand (COD) from landfill leachate generated from the municipal landfill site of Bingol, Turkey. The effect of parameters such as current density, pH, and inter-electrode distance during the electrocoagulation (EC) process on COD removal of the process was investigated. Moreover, for COD removal, the energy consumption and operating costs were calculated for iron electrode under the EC conditions. COD removal efficiency was 72.13% at the current density of 16 mA m-2, pH of 8.05, and the inter-electrode distance of 9 mm at the detention time of 60 min with iron electrode and the COD concentration was reduced from 6,100 mg L-1 to 1,700 mg L-1 by EC. The highest value of the electrical energy and electrode consumptions per kg of COD in the optimum conditions were determined as 0.055 kWh kg-1 COD and 3.43 kg kg-1 COD and the highest operating cost value was found to be 1.41 US$ kg-1 COD for 0-60 min time intervals. | |
| dc.description.sponsorship | Munzur University, (MFTUB015-20) | |
| dc.identifier.doi | 10.2166/wst.2017.528 | |
| dc.identifier.eissn | 1996-9732 | |
| dc.identifier.endpage | 186 | |
| dc.identifier.issn | 0273-1223 | |
| dc.identifier.issue | 1 | |
| dc.identifier.pmid | 29339616 | |
| dc.identifier.scopus | 2-s2.0-85045862697 | |
| dc.identifier.startpage | 177 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/munzur/3679 | |
| dc.identifier.volume | 77 | |
| dc.identifier.wos | WOS:000424763900019 | |
| dc.language.iso | en | |
| dc.publisher | IWA Publishing | |
| dc.relation.ispartof | Water Science and Technology | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | COD removal | |
| dc.subject | Electrocoagulation | |
| dc.subject | Energy and electrode costs | |
| dc.subject | Fe electrode | |
| dc.subject | Landfill leachate | |
| dc.subject.classification | Engineering, Environmental | |
| dc.subject.classification | Environmental Sciences | |
| dc.subject.classification | Water Resources | |
| dc.subject.classification | Engineering | |
| dc.subject.classification | Environmental Sciences & Ecology | |
| dc.subject.other | Biological Oxygen Demand Analysis | |
| dc.subject.other | Electrochemical Techniques | |
| dc.subject.other | Electrodes | |
| dc.subject.other | Hydrogen-Ion Concentration | |
| dc.subject.other | Models, Theoretical | |
| dc.subject.other | Turkey | |
| dc.subject.other | Waste Disposal Facilities | |
| dc.subject.other | Waste Disposal, Fluid | |
| dc.subject.other | Waste Water | |
| dc.subject.other | Water Pollutants, Chemical | |
| dc.subject.other | Water Purification | |
| dc.subject.other | Bingol | |
| dc.subject.other | Chemical oxygen demand | |
| dc.subject.other | Coagulation | |
| dc.subject.other | Costs | |
| dc.subject.other | Electric connectors | |
| dc.subject.other | Energy utilization | |
| dc.subject.other | Iron | |
| dc.subject.other | Operating costs | |
| dc.subject.other | ferric hydroxide | |
| dc.subject.other | oxygen | |
| dc.subject.other | COD removal | |
| dc.subject.other | COD removal efficiency | |
| dc.subject.other | Effect of parameters | |
| dc.subject.other | Electro coagulations | |
| dc.subject.other | Fe electrodes | |
| dc.subject.other | Landfill leachates | |
| dc.subject.other | Municipal landfills | |
| dc.subject.other | Parallel connections | |
| dc.subject.other | cost | |
| dc.subject.other | efficiency measurement | |
| dc.subject.other | electrochemical method | |
| dc.subject.other | electrode | |
| dc.subject.other | energy use | |
| dc.subject.other | landfill | |
| dc.subject.other | leachate | |
| dc.subject.other | pollutant removal | |
| dc.subject.other | Article | |
| dc.subject.other | concentration (parameters) | |
| dc.subject.other | controlled study | |
| dc.subject.other | current density | |
| dc.subject.other | electrocoagulation | |
| dc.subject.other | energy consumption | |
| dc.subject.other | leaching | |
| dc.subject.other | reduction (chemistry) | |
| dc.subject.other | solubility | |
| dc.subject.other | time | |
| dc.subject.other | analysis | |
| dc.subject.other | biochemical oxygen demand | |
| dc.subject.other | chemistry | |
| dc.subject.other | economics | |
| dc.subject.other | electrochemical analysis | |
| dc.subject.other | pH | |
| dc.subject.other | procedures | |
| dc.subject.other | sewage | |
| dc.subject.other | theoretical model | |
| dc.subject.other | waste disposal facility | |
| dc.subject.other | water management | |
| dc.subject.other | water pollutant | |
| dc.subject.other | Leachate treatment | |
| dc.title | COD removal from leachate by electrocoagulation process: Treatment with monopolar electrodes in parallel connection | |
| dc.type | Article | |
| rdl.citation.openalex | 32 | |
| rdl.citation.scopus | 29 | |
| rdl.citation.wos | 29 | |
| rdl.department | Department of Environmental Engineering, Munzur University, Tunceli, Turkey | |
| rdl.department | Department of Environmental Engineering, Ataturk University, Erzurum, Turkey E-mail: | |
| rdl.oa.status | closed | |
| rdl.scopus.quartile | Q2 | |
| rdl.sdg | SDG06 | |
| rdl.sdg | SDG12 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.source.index | PUBMED | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |