Sürdürülebilir Kalkınma Amaçları

Bu dergideki yayınlar

2 →
  • MakaleYalnız künye2018Scopus SJRQ2
    COD removal from leachate by electrocoagulation process: Treatment with monopolar electrodes in parallel connection

    Tanyol, Mehtap; Ogedey, Aysenur; Oguz, Ensar

    This study examines the removal of chemical oxygen demand (COD) from landfill leachate generated from the municipal landfill site of Bingol, Turkey. The effect of parameters such as current density, pH, and inter-electrode distance during the electrocoagulation (EC) process on COD removal of the process was investigated. Moreover, for COD removal, the energy consumption and operating costs were calculated for iron electrode under the EC conditions. COD removal efficiency was 72.13% at the current density of 16 mA m-2, pH of 8.05, and the inter-electrode distance of 9 mm at the detention time of 60 min with iron electrode and the COD concentration was reduced from 6,100 mg L-1 to 1,700 mg L-1 by EC. The highest value of the electrical energy and electrode consumptions per kg of COD in the optimum conditions were determined as 0.055 kWh kg-1 COD and 3.43 kg kg-1 COD and the highest operating cost value was found to be 1.41 US$ kg-1 COD for 0-60 min time intervals.

    • SDG 6 · Temiz Su ve Sanitasyon
    • SDG 12 · Sorumlu Üretim ve Tüketim
    AtıfScopus29WoS29OpenAlex32
    ScopusWeb of SciencePubMedİncele
  • MakaleYalnız künye2017Scopus SJRQ2
    Optimizing electrocoagulation process using experimental design for COD removal from unsanitary landfill leachate

    Ogedey, Aysenur; Tanyol, Mehtap

    Leachate is the most difficult wastewater to be treated due to its complex content and high pollution release. For this reason, since it is not possible to be treated with a single process, a pre-treatment is needed. In the present study, a batch electrocoagulation reactor containing aluminum and iron electrodes was used to reduce chemical oxygen demand (COD) from landfill leachate (Tunceli, Turkey). Optimization of COD elimination was carried out with response surface methodology to describe the interaction effect of four main process independent parameters (current density, inter-electrode distance, pH and time of electrolysis). The optimum current density, inter-electrode distance, pH and time of electrolysis for maximum COD removal (43%) were found to be 19.42 mA/m2, 0.96 cm, 7.23 and 67.64 min, respectively. The results shown that the electrocoagulation process can be used as a pre-treatment step for leachate.

    AtıfScopus15WoS16
    ScopusWeb of SciencePubMedİncele
Tam Kayıt
AlanDeğerDil
creativeworkseries.issn0273-1223
dc.date.accessioned2026-10-28T14:56:57.365344400Z
dc.date.available2026-10-28T14:56:57.365344400Z
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3680
dc.publisherIWA Publishing
dc.rightsinfo:eu-repo/semantics/openAccess
dc.titleWater Science and Technology