Optimizing electrocoagulation process using experimental design for COD removal from unsanitary landfill leachate

MakaleYalnız künyeScopus SJRQ2

Özet

Leachate is the most difficult wastewater to be treated due to its complex content and high pollution release. For this reason, since it is not possible to be treated with a single process, a pre-treatment is needed. In the present study, a batch electrocoagulation reactor containing aluminum and iron electrodes was used to reduce chemical oxygen demand (COD) from landfill leachate (Tunceli, Turkey). Optimization of COD elimination was carried out with response surface methodology to describe the interaction effect of four main process independent parameters (current density, inter-electrode distance, pH and time of electrolysis). The optimum current density, inter-electrode distance, pH and time of electrolysis for maximum COD removal (43%) were found to be 19.42 mA/m2, 0.96 cm, 7.23 and 67.64 min, respectively. The results shown that the electrocoagulation process can be used as a pre-treatment step for leachate.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/3871Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.2166/wst.2017.460Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
15
WoS
16
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOgedey, Aysenur
dc.contributor.authorTanyol, Mehtap
dc.date.accessioned2026-10-28T14:57:14.535815839Z
dc.date.available2026-10-28T14:57:14.535815839Z
dc.date.issued2017
dc.description.abstractLeachate is the most difficult wastewater to be treated due to its complex content and high pollution release. For this reason, since it is not possible to be treated with a single process, a pre-treatment is needed. In the present study, a batch electrocoagulation reactor containing aluminum and iron electrodes was used to reduce chemical oxygen demand (COD) from landfill leachate (Tunceli, Turkey). Optimization of COD elimination was carried out with response surface methodology to describe the interaction effect of four main process independent parameters (current density, inter-electrode distance, pH and time of electrolysis). The optimum current density, inter-electrode distance, pH and time of electrolysis for maximum COD removal (43%) were found to be 19.42 mA/m2, 0.96 cm, 7.23 and 67.64 min, respectively. The results shown that the electrocoagulation process can be used as a pre-treatment step for leachate.
dc.identifier.doi10.2166/wst.2017.460
dc.identifier.eissn1996-9732
dc.identifier.endpage2917
dc.identifier.issn0273-1223
dc.identifier.issue11
dc.identifier.pmid29210678
dc.identifier.scopus2-s2.0-85050873558
dc.identifier.startpage2907
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/3871
dc.identifier.volume76
dc.identifier.wosWOS:000417163700005
dc.language.isoen
dc.publisherIWA Publishing
dc.relation.ispartofWater Science and Technology
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectElectrocoagulation
dc.subjectResponse surface methodology
dc.subjectUnsanitary landfill leachate
dc.subject.classificationEngineering, Environmental
dc.subject.classificationEnvironmental Sciences
dc.subject.classificationWater Resources
dc.subject.classificationEngineering
dc.subject.classificationEnvironmental Sciences & Ecology
dc.subject.otherAluminum
dc.subject.otherBiological Oxygen Demand Analysis
dc.subject.otherElectrochemical Techniques
dc.subject.otherElectrodes
dc.subject.otherHydrogen-Ion Concentration
dc.subject.otherIron
dc.subject.otherTurkey
dc.subject.otherWaste Water
dc.subject.otherWater Pollutants, Chemical
dc.subject.otherTunceli
dc.subject.otherChemical oxygen demand
dc.subject.otherCoagulation
dc.subject.otherElectrolysis
dc.subject.otherSurface properties
dc.subject.otherWastewater treatment
dc.subject.otherElectro coagulations
dc.subject.otherElectrode distances
dc.subject.otherIndependent parameters
dc.subject.otherInteraction effect
dc.subject.otherIron electrodes
dc.subject.otherLandfill leachates
dc.subject.otherResponse surface methodology
dc.subject.otherUnsanitary landfill
dc.subject.otherelectrical method
dc.subject.otherelectrokinesis
dc.subject.otherexperimental design
dc.subject.otherlandfill
dc.subject.otherleachate
dc.subject.otheroptimization
dc.subject.otherparameter estimation
dc.subject.otherpollutant removal
dc.subject.otherArticle
dc.subject.othercurrent density
dc.subject.otherlandfill leachate
dc.subject.otherpH
dc.subject.otherprocess optimization
dc.subject.otherresponse surface method
dc.subject.otherbiochemical oxygen demand
dc.subject.otherchemistry
dc.subject.otherelectrochemical analysis
dc.subject.otherelectrode
dc.subject.otherturkey (bird)
dc.subject.otherwater pollutant
dc.subject.otherLeachate treatment
dc.titleOptimizing electrocoagulation process using experimental design for COD removal from unsanitary landfill leachate
dc.typeArticle
rdl.citation.scopus15
rdl.citation.wos16
rdl.departmentDepartment of Environmental Engineering, Munzur University, Tunceli, Turkey E-mail:
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)