Effect of Longer Waiting Time During OCP and Pre-Applied Cleaning Potential In Corrosion Analysis of Zinc Metal

MakaleAçık Erişim

Özet

Tafel analysis is a widely accepted technique for corrosion studies in electrochemistry. A general literature search for one of the electronegative metals, zinc, revealed serious deviations in corrosion results. In order to understand the reasons behind these deviations, zinc metal was investigated at macro and micro levels during and after the Tafel corrosion analysis. In-situ macro surface investigation during the OCP period and Tafel analysis were performed, and it was found that the zinc surface undergoes proceeding corrosion attack following the immersion in 3.5 wt.% NaCl solution. In-situ macro surface analysis exhibited that the pre-oxidation of the surface proceeds as nonuniform at local regions. SEM-EDS and XRD analysis proved that the particular crystal planes of the zinc form ZnO with increasing immersion time. A linear sweep voltammetry (LSV) technique was applied to detect the oxygen removal and starting hydrogen evolution potentials. Three identical Tafel experiments were performed on samples without any treatment, and another three consecutive Tafel experiments were performed on the samples which applied pre-reduction potential. Obtained results revealed that in-situ pre-applied reduction potential just before the Tafel analysis cleaned the surface and allowed uniform oxide formation, resulting in the lowest standard deviation of the calculated Tafel elements.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/5748Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.46810/tdfd.1306573Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
8
TR Dizin
1
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCihangir, Salih
dc.date.accessioned2026-10-28T15:10:55.938648205Z
dc.date.available2026-10-28T15:10:55.938648205Z
dc.date.issued2023
dc.description.abstractTafel analysis is a widely accepted technique for corrosion studies in electrochemistry. A general literature search for one of the electronegative metals, zinc, revealed serious deviations in corrosion results. In order to understand the reasons behind these deviations, zinc metal was investigated at macro and micro levels during and after the Tafel corrosion analysis. In-situ macro surface investigation during the OCP period and Tafel analysis were performed, and it was found that the zinc surface undergoes proceeding corrosion attack following the immersion in 3.5 wt.% NaCl solution. In-situ macro surface analysis exhibited that the pre-oxidation of the surface proceeds as nonuniform at local regions. SEM-EDS and XRD analysis proved that the particular crystal planes of the zinc form ZnO with increasing immersion time. A linear sweep voltammetry (LSV) technique was applied to detect the oxygen removal and starting hydrogen evolution potentials. Three identical Tafel experiments were performed on samples without any treatment, and another three consecutive Tafel experiments were performed on the samples which applied pre-reduction potential. Obtained results revealed that in-situ pre-applied reduction potential just before the Tafel analysis cleaned the surface and allowed uniform oxide formation, resulting in the lowest standard deviation of the calculated Tafel elements.
dc.identifier.doi10.46810/tdfd.1306573
dc.identifier.eissn2149-6366
dc.identifier.endpage23
dc.identifier.issue3
dc.identifier.startpage15
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/5748
dc.identifier.volume12
dc.language.isoen
dc.relation.ispartofTürk Doğa ve Fen Dergisi
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectKimya, Uygulamalı
dc.subjectMalzeme Bilimleri, Özellik ve Test
dc.subjectKimya, Tıbbi
dc.subjectMalzeme Bilimleri, Biyomalzemeler
dc.titleEffect of Longer Waiting Time During OCP and Pre-Applied Cleaning Potential In Corrosion Analysis of Zinc Metal
dc.typeArticle
rdl.citation.openalex8
rdl.citation.trdizin1
rdl.oa.statushybrid
rdl.oa.urlhttps://dergipark.org.tr/en/download/article-file/3174805