A novel inter-story drift limit proposal for TBEC2018 and fragility prognosis with TSC2007

MakaleAçık Erişim
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 11 · Sürdürülebilir Şehirler ve Topluluklar

Özet

The basic purpose of this paper is to investigate and propose a novel inter-story drift limits for the currentTurkish Seismic Code to get easy structural assessment by using software. For this aim, numerical analysiswas performed by modeling two types of RC frame structures. One of them is 5 stories, the other of them is7 stories. Two different concrete classes, C20 and C25, were considered and three tension reinforcementratios were considered for analysis. Tension reinforcement ratios were determined by half of the compressivereinforcement, equal to compressive reinforcement and double the compressive reinforcement ratio.Incremental dynamic analyses (IDA) were performed on these buildings. In this study to execute IDA, elevenseismic acceleration benchmark records were multiplied with various scaling factors from 0.2 to 1.0.Maximum base shear and corresponding roof displacement responses obtained from IDA curves weregenerated according to these responses. IDA curves were compared with each other by deriving fragilitygraphs. According to results, proposed limits for the current Turkish seismic code (TBEC-2018) provide,0.6%, 2.4% and 3.3% respectively for MN, GV and GC, rather safe limits compared to drift limits presentedin the foredate seismic code (TSC-2007).

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/6659Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
2
TR Dizin
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOnat, Onur
dc.contributor.authorYön, Burak
dc.date.accessioned2026-10-28T15:11:53.066013600Z
dc.date.available2026-10-28T15:11:53.066013600Z
dc.date.issued2021
dc.description.abstractThe basic purpose of this paper is to investigate and propose a novel inter-story drift limits for the currentTurkish Seismic Code to get easy structural assessment by using software. For this aim, numerical analysiswas performed by modeling two types of RC frame structures. One of them is 5 stories, the other of them is7 stories. Two different concrete classes, C20 and C25, were considered and three tension reinforcementratios were considered for analysis. Tension reinforcement ratios were determined by half of the compressivereinforcement, equal to compressive reinforcement and double the compressive reinforcement ratio.Incremental dynamic analyses (IDA) were performed on these buildings. In this study to execute IDA, elevenseismic acceleration benchmark records were multiplied with various scaling factors from 0.2 to 1.0.Maximum base shear and corresponding roof displacement responses obtained from IDA curves weregenerated according to these responses. IDA curves were compared with each other by deriving fragilitygraphs. According to results, proposed limits for the current Turkish seismic code (TBEC-2018) provide,0.6%, 2.4% and 3.3% respectively for MN, GV and GC, rather safe limits compared to drift limits presentedin the foredate seismic code (TSC-2007).
dc.identifier.doi10.31462/jseam.2021.04068082
dc.identifier.eissn2630-5763
dc.identifier.endpage82
dc.identifier.issue2
dc.identifier.startpage68
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/6659
dc.identifier.volume4
dc.language.isoen
dc.relation.ispartofJournal of Structural Engineering & Applied Mechanics (Online)
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectİnşaat Mühendisliği
dc.titleA novel inter-story drift limit proposal for TBEC2018 and fragility prognosis with TSC2007
dc.typeArticle
rdl.citation.openalex2
rdl.citation.trdizin2
rdl.oa.statusbronze
rdl.oa.urlhttps://doi.org/10.31462/jseam.2021.04068082
rdl.sdgSDG09
rdl.sdgSDG11
rdl.source.indexTRDIZIN