The influence of cold rolling and hydroxyapatite coating on the mechanostructure, corrosion resistance, cell viability, and antibacterial activity of ZnCu biodegradable implants

MakaleAçık ErişimScopus SJRQ2
  • SDG 3 · Sağlık ve Kaliteli Yaşam

Özet

Zinc (Zn) and its alloys exhibit great potential for utilization in biodegradable bone implants. Zn-1Cu biodegradable alloy was produced and were cold rolled at two different deformation rates of 47 and 61%. The samples have been bioceramic coated with the sol–gel method and microstructure-mechanical property changes, corrosion behavior and biocompatibility of the samples were investigated. They were characterized by Optical, SEM, XRD and wettability analysis. The rolled samples showed a significant increase in hardness when compared to the non-rolled samples. The unrolled and 47% rolled samples showed better corrosion resistance compared to 61% rolled samples. Antibacterial effects of the base and sol–gel-coated groups showed higher cell viability ratios than the uncoated groups. Cell viability increased significantly in 47% of the rolled samples after 24, 48, and 72 h, however decreased by up to 70% in 61% of the rolled samples. Graphical abstract: (Figure presented.).

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/1830Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1557/s43578-024-01340-6Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
WoS
2
OpenAlex
2
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorAksakal, B.
dc.contributor.authorKaradogan, S.A.
dc.contributor.authorAslan, N.
dc.contributor.authorFidan, F.
dc.contributor.authorYilmazer, Y.
dc.contributor.authorSezek, S.
dc.date.accessioned2026-10-28T14:54:37.580016995Z
dc.date.available2026-10-28T14:54:37.580016995Z
dc.date.issued2024
dc.description.abstractZinc (Zn) and its alloys exhibit great potential for utilization in biodegradable bone implants. Zn-1Cu biodegradable alloy was produced and were cold rolled at two different deformation rates of 47 and 61%. The samples have been bioceramic coated with the sol–gel method and microstructure-mechanical property changes, corrosion behavior and biocompatibility of the samples were investigated. They were characterized by Optical, SEM, XRD and wettability analysis. The rolled samples showed a significant increase in hardness when compared to the non-rolled samples. The unrolled and 47% rolled samples showed better corrosion resistance compared to 61% rolled samples. Antibacterial effects of the base and sol–gel-coated groups showed higher cell viability ratios than the uncoated groups. Cell viability increased significantly in 47% of the rolled samples after 24, 48, and 72 h, however decreased by up to 70% in 61% of the rolled samples. Graphical abstract: (Figure presented.).
dc.identifier.doi10.1557/s43578-024-01340-6
dc.identifier.eissn2044-5326
dc.identifier.endpage1715
dc.identifier.issn0884-2914
dc.identifier.issue11
dc.identifier.scopus2-s2.0-85191330581
dc.identifier.startpage1701
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/1830
dc.identifier.volume39
dc.identifier.wosWOS:001208714200002
dc.language.isoen
dc.publisherSpringer Nature
dc.relation.ispartofJournal of Materials Research
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAntibacterial activity
dc.subjectBiodegradable implants
dc.subjectCell viability
dc.subjectCorrosion
dc.subjectRolling
dc.subjectSol–gel
dc.subject.classificationMaterials Science, Multidisciplinary
dc.subject.classificationMaterials Science
dc.subject.otherBinary alloys
dc.subject.otherBiocompatibility
dc.subject.otherBiomechanics
dc.subject.otherCells
dc.subject.otherCold rolling
dc.subject.otherCopper alloys
dc.subject.otherCorrosion resistant alloys
dc.subject.otherCorrosion resistant coatings
dc.subject.otherCorrosive effects
dc.subject.otherCytology
dc.subject.otherHydroxyapatite
dc.subject.otherMetal cladding
dc.subject.otherSols
dc.subject.otherZinc alloys
dc.subject.otherAnti-bacterial activity
dc.subject.otherBiodegradable alloys
dc.subject.otherBiodegradable implants
dc.subject.otherBone implant
dc.subject.otherCell viability
dc.subject.otherCold-rolled
dc.subject.otherDeformation rates
dc.subject.otherHydroxyapatite coating
dc.subject.otherRolling
dc.subject.otherSol'gel
dc.subject.otherCorrosion resistance
dc.titleThe influence of cold rolling and hydroxyapatite coating on the mechanostructure, corrosion resistance, cell viability, and antibacterial activity of ZnCu biodegradable implants
dc.typeArticle
rdl.citation.openalex2
rdl.citation.scopus2
rdl.citation.wos2
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/11508/53909
rdl.scopus.quartileQ2
rdl.sdgSDG03
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)