Determination and monitoring of tetracycline and degradation products in livestock slaughterhouse wastewater treatment plant effluent

MakaleAçık Erişim
  • SDG 3 · Sağlık ve Kaliteli Yaşam
  • SDG 6 · Temiz Su ve Sanitasyon
  • SDG 12 · Sorumlu Üretim ve Tüketim

Özet

Aim of our study was the determination and monitoring of tetracycline (TC) and degradation products (DEP) in livestock slaughterhouse wastewater treatment plant (SWWTP) effluent. For this purpose, TC and DEP values in SWWTP were investigated. The concentrations of TC and DEP were monitored for 12 months. TC, 4-epitetracycline (ETC), 4-epianhydrotetracycline (EATC), anhydrotetracycline (ATC), and physicochemical parameters of pH, suspended solids (SS), BOD5, COD, and TP were calculated. The maximum TC concentration was determined as 1.68±0.08 µg/L in March and the minimum TC was 1.08±0.05 µg/L in January. The maximum ETC was 2.93±0.14 µg/L in March and April. The minimum ETC was 1.98±0.1 µg/L in January. EATC was 10.82±0.5 µg/L in September, and minimum EATC value was determined as 9.14±0.4 µg/L in March. The maximum ATC value was 8.62±0.4 µg/L in June and the lowest ATC value was 6.61±0.3 µg/L in September. Concentrations of TC and DEP detected in SWWTP effluent were listed in descending order as EATC> ATC> ETC> TC.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/munzur/6391Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.35860/iarej.1265230Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
OpenAlex
1
TR Dizin
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTopal, Murat
dc.contributor.authorTopal, E.Işıl Arslan
dc.contributor.authorÖbek, Erdal
dc.date.accessioned2026-10-28T15:11:34.518649521Z
dc.date.available2026-10-28T15:11:34.518649521Z
dc.date.issued2023
dc.description.abstractAim of our study was the determination and monitoring of tetracycline (TC) and degradation products (DEP) in livestock slaughterhouse wastewater treatment plant (SWWTP) effluent. For this purpose, TC and DEP values in SWWTP were investigated. The concentrations of TC and DEP were monitored for 12 months. TC, 4-epitetracycline (ETC), 4-epianhydrotetracycline (EATC), anhydrotetracycline (ATC), and physicochemical parameters of pH, suspended solids (SS), BOD5, COD, and TP were calculated. The maximum TC concentration was determined as 1.68±0.08 µg/L in March and the minimum TC was 1.08±0.05 µg/L in January. The maximum ETC was 2.93±0.14 µg/L in March and April. The minimum ETC was 1.98±0.1 µg/L in January. EATC was 10.82±0.5 µg/L in September, and minimum EATC value was determined as 9.14±0.4 µg/L in March. The maximum ATC value was 8.62±0.4 µg/L in June and the lowest ATC value was 6.61±0.3 µg/L in September. Concentrations of TC and DEP detected in SWWTP effluent were listed in descending order as EATC> ATC> ETC> TC.
dc.identifier.doi10.35860/iarej.1265230
dc.identifier.eissn2618-575X
dc.identifier.endpage115
dc.identifier.issue2
dc.identifier.startpage109
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/munzur/6391
dc.identifier.volume7
dc.language.isoen
dc.relation.ispartofInternational Advanced Researches and Engineering Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectHalk ve Çevre Sağlığı
dc.subjectMikrobiyoloji
dc.subjectBiyoteknoloji ve Uygulamalı Mikrobiyoloji
dc.subjectÇevre Mühendisliği
dc.titleDetermination and monitoring of tetracycline and degradation products in livestock slaughterhouse wastewater treatment plant effluent
dc.typeArticle
rdl.citation.openalex1
rdl.citation.trdizin0
rdl.oa.statusgold
rdl.oa.urlhttp://dx.doi.org/10.35860/iarej.1265230
rdl.sdgSDG06
rdl.sdgSDG12
rdl.sdgSDG03
rdl.source.indexTRDIZIN