Sürdürülebilir Kalkınma Amaçları
Yayınlar
- MakaleAçık Erişim2026Scopus SJRQ2Comparative Microstructural, Mechanical, and Tribological Evaluation of Cu Matrix Composites Reinforced with B4C, B, Cr, Co, Al2O3, and Graphite via Powder Metallurgy
Macit, Cevher Kursat; Gürgenç, Turan; Aksakal, Bunyamin; Aslan, Naim
Copper and its alloys are widely used in electrical, automotive, aerospace, and energy applications because of their excellent thermal and electrical conductivity. However, the low hardness and poor wear resistance of pure Cu limit its use under tribologically demanding sliding conditions. In this study, Cu matrix composites reinforced with 1 wt.% boron carbide (B4C), boron (B), chromium (Cr), cobalt (Co), alumina (Al2O3), and graphite (Gr) were fabricated by powder metallurgy and comparatively evaluated under identical processing and testing conditions. Phase constitution and microstructural characteristics were analyzed by XRD, SEM, and EDS, while mechanical and tribological behavior was assessed by Vickers hardness and dry sliding wear tests. All reinforcements improved the hardness of the Cu matrix compared with unreinforced Cu. The hardness increase followed the order Cu–B4C (68.91%) > Cu–B (66.43%) > Cu–Gr (63.97%) > Cu–Al2O3 (61.79%) > Cu–Cr (42.69%) > Cu–Co (36.04%). Dry sliding wear tests, performed under a 10 N normal load, 0.05 m s−1 sliding speed, and 1000 m sliding distance against a 316L stainless-steel ball, showed that all reinforced composites exhibited lower mass loss and more stable sliding behavior than pure Cu. Among all samples, Cu–B4C displayed the best wear performance, with a 154.8% improvement in wear resistance relative to pure Cu. SEM analysis of the worn surfaces revealed that reinforcement addition reduced severe plastic deformation, groove formation, and delamination, leading to a more stable wear regime. Graphite- and boron-containing composites benefited from interfacial lubrication and contact stabilization, whereas B4C and Al2O3 improved wear resistance through rigid-particle strengthening and enhanced load-bearing capacity. By comparing ceramic, metalloid, metallic, oxide, and solid-lubricating reinforcements at the same low addition level and under identical processing and testing conditions, this study provides a reinforcement-selection framework for Cu-based composites requiring improved hardness and dry-sliding durability.
AtıfScopus2WoS2OpenAlex2İncele
- MakaleAçık Erişim2024Effects of Porosity and Boron Reinforcement in AISI 316L Stainless Steel for Biomedical Applications
Aslan, Naim; Aksakal, Bunyamin; Fidan, Ferzan
AISI 316L stainless steel (SS) is one of the most widely used biomaterials in the manufacture of implants and biomaterials. It has advantages over equivalent biomaterials such as low cost, good mechanical properties and biocompatibility. The pores found in porous biomaterials provide mechanical interlock, ensuring strong attachment of the implant to the tissue. In this study, 20%, 30% and 40% by volume of polyvinyl alcohol (PVA) and Boron powder were added into 316L powder to obtain porous SS implant. To investigate the effect of porosity and boron effect on the stainless-steel implant material, the samples produced in PVA and Boron added groups, were sintered at 1180 oC under an argon atmosphere. With the evaporation of PVA in the structure, porous and boron added samples were obtained in two groups. Finally, the samples were subjected to Brinell hardness and compression tests and analyzed by SEM, EDS and XRD. As a result of the hardness tests, the highest values were measured as 37.006, 31.32, 25.28 HB. 39.5, 34.5, 26.2 MPa strengths were measured for 20%, 30% and 40% porous samples respectively.
AtıfOpenAlex1
İncele - Kitap BölümüAçık Erişim2023Production technique–structure relationship in bioceramic-coated scaffold applications
Aslan, Naim; Topuz, Mehmet; Aksakal, Bunyamin; Dikici, Burak
It is well known that the surface of metal-based implants is very resistive in aggressive body environments due to the noble oxide layer naturally formed on their surfaces. However, their osseointegration properties are very low. By the way, specific cells attached are desired on the implant surface when the surface of an implant connects with tissue in many circumstances. Thus in parallel with technological developments, biomedical engineering focuses on the growth of new tissue on the implant surface or in the porosities of the implant. The bulk properties of metallic scaffolds, especially Young’s modulus, can be controlled by the porosity ratio of the scaffold but cannot form a bond between the implant and tissue interfaces. Thus the coating of scaffold walls with a bioactive material is required. In this chapter, bioceramic coating techniques of scaffolds, mechanical and corrosion behavior, biocompatibility, and interactions of surface/tissue interface, especially considering the last published reports, were reviewed, in detail.
AtıfScopus4OpenAlex4İncele
- MakaleYalnız künye2022Scopus SJRQ2Silver/selenium/chitosan co-substituted bioceramic coatings of Ni–Ti alloy: Antibacterial efficiency and cell viability
Say, Yakup; Aksakal, Bunyamin; Sinirlioglu, Zeynep A.
The effects of silver (Ag), selenium (Se), and chitosan (Cht) additives on the antibacterial activity and cell viability of NiTi were investigated. Three different hydroxyapatite (HA)-based bioceramic coatings to improve the antibacterial activity and cell viability of NiTi; HA, HA/Ag, and HA/Se–Cht were applied to NiTi substrates by a sol–gel method. The coated samples were characterized by scanning electron microscopy–electron-dispersive spectroscopy and X-ray diffraction and surface hardnesses were measured. The antimicrobial efficiency of the coatings and uncoated surfaces were tested against Escherichia coli-JM 103 and Staphylococcus aureus-ATCC29293. In vitro cell–material interactions using Saos-2 osteoblast cells were characterized by a 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (mitochondrial activity test) assay for cell viability. A homogeneous, crack-free, and porous surface morphology is achieved in coatings. It has been shown that the Se–Cht additives did not have a significant effect on the surface hardness of the HA coating, but the Ag additive increased the hardness. Through in vitro antibacterial activity and cell viability tests, it was shown that Ag additive to bioceramic coatings significantly increased (p <.05) antibacterial properties but caused a decrease in cell viability. However, although Se–Cht additives did not have a significant effect on antibacterial properties (p <.05), it was observed that they increased cell viability.
AtıfScopus8WoS8OpenAlex2İncele
- MakaleYalnız künye2017Scopus SJRQ1The effect of Zirconia/Yttria/Silver substitutions on mechanostructure and cell viability of the synthesized bioceramic bone grafts
Aksakal, Bunyamin; Demirel, Mehtap
Hydroxyapatite (HA) based biografts were synthesized by substitution of Zirconia (Zr), Yttria (Y2O3) and Silver (Ag) using the sol-gel method. Fabricated bone grafts (H40ZrYt and H50Yt10) were compared with a control biograft. The effects of Zr and Y2O3 and Ag additions on the morphological, mechanical and cell viability of the synthesized biografts were analyzed. The biografts were characterized by X-ray Diffractometer (XRD) and Scanning Electron Microscope (SEM). All biografts were then embedded into the drilled holes (D=3.2 mm) in rabbit femurs. The rabbits were then sacrificed after twelve weeks. Three-point bending (3-PB) tests were conducted on defected and grafted regions. Flexural strength values were found to be 347, 149 and 180 MPa, for the H40ZrYt, H50Yt10 and the control/commercial graft, respectively. Cell viability results indicated that the percentage viability ratios slightly increased after the substitution of Ag into the H50Yt10 biograft at 0.1 and 0.3 µg/ml concentrations and into the H40ZrYt biograft at a 0.1 µg/ml concentration. Although the cell viability was a bit lower in the H50Yt10 graft, the H40ZrYt graft achieved better results compared to the counterpart grafts. Furthermore, the hardness of both of the novel fabricated grafts were found to be higher than the control/commercial graft, however, as the flexture strength of H40ZrYt was higher but H50Yt10 was lower than the control/commercial graft.
AtıfScopus11WoS10OpenAlex13İncele
- MakaleAçık Erişim2016Scopus SJRQ3Biomechanical comparison of straight and helical compression plates for fixation of transverse and oblique bone fractures: Modeling and experiments
Sezek, Sinan; Aksakal, Bunyamin; Gürger, Murat; Malkoc, Melih; Say, Y.
AtıfOpenAlex5İncele
- MakaleYalnız künye2016Scopus SJRQ1Effect of hydroxyapatite/SiO2 hybride coatings on surface morphology and corrosion resistance of REX-734 alloy
Say, Yakup; Aksakal, Bunyamin; Dikici, Burak
REX-734 stainless steel alloy was coated with hydroxyapatite (HA)-silicon dioxide (SiO2) composite (hybride) coatings by using the sol-gel method. Surface morphologies, adhesion resistances and corrosion behaviors of the coatings were examined and the characterization of the coatings was performed by using XRD, SEM, and EDS. It was observed that porous and crack-free surface morphology enhanced adhesion strength of the coatings. Through the shear tests, it was found that the adhesion resistance was 25.14 MPa in HA coatings and 25.47 MPa in HA-SiO2 coatings. Corrosion analyses of the coatings were performed by using potentiodynamic polarization (PDS) tests. It was determined that corrosion dimples formed on the coating surface and the corrosion resistance in HA+SiO2 coatings increased with decreasing porosity; however, in the further steps of corrosion, it reached to the base material by causing a pitting effect on the coated surface. (C) 2016 Elsevier Ltd and Techna Group S.r.l. All rights reserved.
AtıfWoS36OpenAlex39İncele

